diff options
author | oci <oci@ae88bc3d-4319-0410-8dbf-d08b4c9d3795> | 2000-03-24 20:51:21 +0000 |
---|---|---|
committer | oci <oci@ae88bc3d-4319-0410-8dbf-d08b4c9d3795> | 2000-03-24 20:51:21 +0000 |
commit | 48293318d83e42e7c51a84d3b51fcf650eed8386 (patch) | |
tree | 90323f3d20b3ba02afa12401dfacb7f57478b71b | |
parent | c299e8e460856e52b2f702fd34bca31f27ac0548 (diff) | |
download | ATCD-48293318d83e42e7c51a84d3b51fcf650eed8386.tar.gz |
Fix problems with CEC documentation
-rw-r--r-- | TAO/docs/cec_options.html | 27 |
1 files changed, 18 insertions, 9 deletions
diff --git a/TAO/docs/cec_options.html b/TAO/docs/cec_options.html index 827c8ac06af..c7313026992 100644 --- a/TAO/docs/cec_options.html +++ b/TAO/docs/cec_options.html @@ -62,11 +62,8 @@ static CEC_Factory "-CECDispatching reactive ....." <TD>Select the dispatching strategy used by the COS event service. A <EM>reactive</EM> strategy will use the same thread that received the event from the supplier to - push the event to all the consumers, - the <EM>priority</EM> strategy will use a prioritized pool - of threads and will query the scheduling service to select - the thread that will dispatch each event; - the <EM>mt</EM> strategy will also use a pool of threads, + push the event to all the consumers. + The <EM>mt</EM> strategy will also use a pool of threads, but the thread to dispatch is randomly selected. </TD> </TR> @@ -76,7 +73,7 @@ static CEC_Factory "-CECDispatching reactive ....." <TD><CODE>-CECDispatchingThreads</CODE> <EM>number_of_threads</EM> </TD> - <TD>Select the number of threads used bythe <EM>mt</EM> + <TD>Select the number of threads used by the <EM>mt</EM> dispatching strategy. </TD> </TR> @@ -262,9 +259,9 @@ static CEC_Factory "-CECDispatching reactive ....." </P> <PRE> - TAO_EC_EventChannel (const TAO_CEC_EventChannel_Attributes& attributes, - TAO_CEC_Factory* factory = 0, - int own_factory = 0); + TAO_CEC_EventChannel (const TAO_CEC_EventChannel_Attributes& attributes, + TAO_CEC_Factory* factory = 0, + int own_factory = 0); </PRE> <P>The <CODE>factory</CODE> is an optional parameter to override @@ -307,6 +304,18 @@ static CEC_Factory "-CECDispatching reactive ....." </TD> </TR> + <TR><TD><CODE>disconnect_callbacks</CODE></TD> + <TD>It not zero the event channel will send disconnect + callbacks when a disconnect method is called on a Proxy. + In other words, if a consumer calls + <CODE>disconnect_push_supplier()</CODE> on its proxy the + EC will invoke <CODE>disconnect_push_consumer()</CODE> + on the consumer. A similar thing is done for suppliers. + It is a matter of debate what the spec requires for the + regular event service. + </TD> + </TR> + <TR><TD><CODE>busy_hwm</CODE></TD> <TD>When using the delayed strategy to update ProxyPushSupplier sets this flag controls the maximum |