summaryrefslogtreecommitdiff
path: root/TAO/docs/Options.html
blob: 22197133429c5be1ecd02bde18386555468cebaf (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<!-- $Id$ -->
  <title>Options for TAO Components</title>
</head>
<body bgcolor="#ffffff" link="#000fff" vlink="#ff0f0f" text="#000000">
<hr>
<p></p>
<h2 align="center">Options for TAO Components</h2>
<h3>Table of Contents</h3>
<ul>
  <li><a href="#MOT">Introduction</a> </li>
  <li><a href="#choose">Choosing the Right Approach</a> </li>
  <li><a href="#EXP">TAO's ORB Configuration Options</a>
    <ul>
      <li><a href="#EV">Environment Variables</a> </li>
      <li><a href="#CLO">Command-line Options</a>
        <ol>
          <li><a href="#CSCB">Controlling Service Configurator Behavior </a>
          </li>
          <li><a href="#CDI">Controlling Debugging Information </a> </li>
          <li><a href="#ORP">Optimizing Request Processing </a> </li>
          <li><a href="#CMPS">Connection Management and Protocol
Selection </a> </li>
          <li><a href="#MO">Miscellaneous Options </a></li>
        </ol>
      </li>
      <li><a href="#SVC">Service Configuration File </a>
        <ol>
          <li><a href="#TRF">Simple and Advanced Resource Factories </a>
            <ol>
              <li><a href="#TDRF">TAO_Default_Resource_Factory </a> </li>
              <li><a href="#TARF">TAO_Advanced_Resource_Factory </a></li>
            </ol>
          </li>
          <li><a href="#TSSF">Server_Strategy_Factory </a> </li>
          <li><a href="#TCSF">Client_Strategy_Factory </a></li>
        </ol>
      </li>
    </ul>
  </li>
</ul>
<hr>
<h3><b><a name="MOT">Introduction</a></b></h3>
TAO is a highly flexible ORB that contains a wide range of ORB
configuration options. One or more of these options can be combined
to meet various application requirements, such as low-latency,
predictable real-time behavior, or small memory footprint. TAO's ORB
configuration options are managed by an object-oriented framework
within the ORB Core that contains the following types of entities:
<ul>
  <li><b>Settings</b>, which are options that can be assigned values
differing from their default settings. Examples include setting the
size of a Portable Object Adapter (POA)'s active object map or
configuring the ORB to print debugging information as it processes
requests. A few of these are run-time options, while a majority of
them are compile-time options.
    <p></p>
  </li>
  <li><b>Resources</b>, which are objects used internally by TAO, such
as a <em>reactor</em> framework that demultiplexes new connection and
data requests from a client or <em>synchronization mechanisms</em>
used to regulate access to certain parts of the ORB.
    <p></p>
  </li>
  <li><b>Strategies</b>, which are objects that use the <b>Resource</b>
entities to perform various ORB tasks, such as connection management,
concurrency, and demultiplexing.
    <p></p>
  </li>
  <li><b>Factories</b>, which TAO uses to create and consolidate its
many resources and strategies into a manageable number of factories
that can be (re)configured into the ORB conveniently and consistently
by ORB and application developers.
    <p></p>
  </li>
</ul>
The set of TAO ORB configuration options that are represented by the
settings, resources, strategies, and factories can be specified via
<b>environment variables</b>, <b>service configuration files</b>, and
<b>command-line arguments</b>, as outlined below:
<ul>
  <li> <b>Environment variables</b> are limited to specifying the
interoperable object reference (IOR) and port number of TAO's Naming
Service, Trading Service and Implementation Repository. They are
limited in flexibility and don't provide the most important
configuration hooks necessary to configure TAO for real-time and
high-performance applications.
    <p></p>
  </li>
  <li> <b>Command-line options</b> are passed to the ORB
initialization
factory method, <code>CORBA::ORB_init()</code>, by an application
using the standard <i>argc/argv</i> tuple passed to the application's
    <code>main()</code>. Most of the options that can be exercised
through
environment variables can also be manipulated through command-line
options. Command-line options override the environment variable
settings if both are enabled.
    <p></p>
  </li>
  <li> The <b>Service Configurator</b> is a framework that can be used
to statically and dynamically configure components into middleware and
applications. The information comprising the names of these
components and their corresponding options are specified in a service
configurator file, whose default file name is
    <code>svc.conf</code>. The service configurator is opened and
processed by the ORB in <code>CORBA::ORB_init()</code>. The service
configurator processing is done after all the command-line options
have been parsed.
  </li>
</ul>
<p></p>
<hr width="25%" align="left">
<p></p>
<h3><a name="choose">Choosing the Right Approach</a></h3>
TAO's command-line options are useful when there's a fixed set of
configuration options, each of which has a predefined list of
alternative values. Conversely, TAO's service configurator file is
useful for configuring a broader range of resources, strategies, and
factories. Generally speaking, the service configurator file allows
the user to <br>
<ul>
  <li>configure the existing components (<em>i.e.</em>, resources,
strategies and factories) based on the predefined list of alternatives
that TAO provides or
    <p> </p>
  </li>
  <li>extend the existing factories by providing user-defined
components and dynamically load them through the service configurator
mechanism. </li>
</ul>
Additionally, the service configurator mechanism allows an
application to control the behavior of the ORB using extensible
configuration information. In general, the command-line configuration
options are provided in TAO
in order to leverage preexisting configuration settings that are
compiled within the TAO ORB. Users are not allowed to change these
settings. In contrast, those options that require more flexible
manipulation of resources, strategies, and factories must be
configured via <a href="#SVC">service configuration files</a>. As a
result, the command-line options and the service configurator options
cannot be used interchangeably.
<p></p>
<hr>
<h3><b><a name="EXP">TAO's ORB Configuration Options</a></b></h3>
This section provides a detailed overview of how to configure TAO's
options using environment variables, command-line options, and service
configuration files.
<p></p>
<hr width="25%" align="left">
<h3><a name="EV">Environment Variables</a></h3>
As mentioned earlier, environment variables have a limited use in TAO
ORB configuration. The currently supported environment variables are
listed below. They are used to specify the IOR and port numbers for
three of TAO's ORB services.
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Environment Variable</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>NameServicePort</code> <em>which</em></td>
        <td>Specifies which port the Naming Service is listening on for
multicast requests. </td>
      </tr>
      <tr>
        <td><code>TradingServicePort</code> <em>which</em></td>
        <td>Specifies which port the Trading Service is listening on
for multicast requests. </td>
      </tr>
      <tr>
        <td><code>ImplRepoServicePort</code> <em>which</em></td>
        <td>Specifies which port the Implementation Repository is
listening on for multicast requests. </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
In addition to being able to define the port where these known services
are listening for multicast requests, as above, it is possible to set
an environment variable that specifies the IOR of any named service.
For example <code>NameServiceIOR=&lt;which&gt;,TradingServiceIOR=&lt;which&gt;,
ImplRepoServiceIOR=&lt;which&gt;, MyServiceIOR=&lt;which&gt;</code>. This
will have a similar effect to defining an -ORBInitRef value on the
command line (see below). Any value set as a command line -ORBInitRef
option will override any value set as an environment variable for the
same service name.<br>
<br>
In general, setting environment variables is not particularly portable
or convenient, which is why users can also set these options via
command-line options. The example shown below demonstrates a
deployment scenario where the client and Naming Service run on the
same host:
<p><code>
% NameService.exe -ORBEndpoint iiop://localhost:12345
</code></p>
<p><code>
% client.exe -ORBInitRef NameService=corbaloc:iiop:localhost:12345/NameService
</code></p>
<p>An explanation of these command-line options appears below. </p>
<p></p>
<hr width="25%" align="left">
<h3><a name="CLO">Command-line Options</a></h3>
TAO's run-time behavior can also be controlled by passing options via
the CORBA initialization method <code>CORBA::ORB_init()</code>. ORB
initialization options are commonly passed into the program from the
command-line, using the <code>argc</code> and <code>argv</code>
parameters available to the <code>main()</code> function.
<p>Command-line options can be classified into the following groups
according to their purposes:</p>
<ol>
  <li><a href="#CSCB">Controlling Service Configurator Behavior</a> </li>
  <li><a href="#CDI">Controlling Debugging Information</a> </li>
  <li><a href="#ORP">Optimizing Request Processing</a> </li>
  <li><a href="#CMPS">Connection Management and Protocol Selection</a> </li>
  <li><a href="#MO">Miscellaneous Options</a>
  </li>
</ol>
We describe each of these five groups of options below.
<p></p>
<h4><a name="CSCB">1. Controlling Service Configurator Behavior</a></h4>
The options described below influence the behavior of the ORB's <a
 href="#SVC">service configurator, which is opened and processed <em>after</em>
the command-line options
have been parsed. </a>
<p></p>
<blockquote><a href="#SVC"> </a>
  <p><a href="#SVC"> </a>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBSvcConf</code> <em>config filename</em></td>
        <td>Specifies the name of the file used to read service
configuration directives via the Service Configurator framework. By
default, a service configurator-based application will look for a file
named <code>"svc.conf"</code> in the current directory. </td>
      </tr>
      <tr>
        <td><code>-ORBSvcConfDirective</code> <em>directivestring</em></td>
        <td>Specifies a service configuration directive, which is
passed to the Service Configurator. You can pass multiple of these
options on the same command-line. </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="CDI">2. Controlling Debugging Information</a></h4>
During application development and testing, it is often necessary to
control the amount and type of debugging information output by the
ORB. The following options enable TAO to provide debugging
information at several levels of granularity.
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBDebug</code></td>
        <td>Instructs the ORB to print debugging messages from the
service configurator framework. This option does not have a value but
is used as a toggle to enable or disable debugging messages.</td>
      </tr>
      <tr>
        <td><code>-ORBDebugLevel </code><em>level</em></td>
        <td>Control the level of debugging in the ORB. Higher numbers
generate more output (try 10). The default value of this option is 0.</td>
      </tr>
      <tr>
        <td><code>-ORBVerboseLogging <em>level (0|1|2)</em</code></td>
        <td>Controls the amount of status data printed on each line of
        the debug log. Higher numbers generate more output.
        The default value of this option is 0. </td>
      </tr>
      <tr>
        <td><code>-ORBLogFile</code> <em>Logfilename</em></td>
        <td>Causes all <code>ACE_DEBUG</code> and <code>ACE_ERROR</code>
output to be redirected to the designated <code>Logfilename</code>. </td>
      </tr>
      <tr>
        <td><code>-ORBObjRefStyle</code> <em>IOR/URL</em></td>
        <td>Specifies the user-visible style of object references. The <code>IOR</code>
style (default) is the conventional CORBA object reference, whereas the
        <code>URL</code> style looks more like a URL.
        </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="ORP">3. Optimizing Request Processing</a></h4>
It is often possible to <a href="performance.html">increase TAO's
throughput and reduce latency</a> by optimizing certain stages of
request processing in the ORB. The following command-line options
control various optimizations during request processing.
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBCDRTradeoff</code> <em>maxsize</em></td>
        <td><a name="-ORBCDRTradeoff"></a>Control the strategy to
tradeoff between copy vs. no copy marshaling of octet sequences. If an
octet sequence is smaller than <code>maxsize</code> (which defaults to
        <code>ACE_DEFAULT_CDR_MEMORY_TRADEOFF</code>) -- and the
current message block contains enough space for it -- the octet
sequence is copied instead of appended to the CDR stream. </td>
      </tr>
      <tr>
        <td><code>-ORBMaxMessageSize</code> <em>maxsize</em></td>
        <td><a name="-ORBMaxMessageSize"></a>Set maximum size of
              outgoing GIOP request/reply.  The request or reply
              being sent will be fragmented, if necessary.</td>
      </tr>
      <tr>
        <td><code>-ORBCollocation</code> <em>global/per-orb/no</em></td>
        <td><a name="-ORBCollocation"></a>Specifies the use of
collocation object optimization. If <code>global</code> is specified
(default), objects in the same process will be treated as collocated.
If <code>per-orb</code> is specified, only objects in the same ORB are
treated as collocated. When <em>no</em> is specified, no objects are
treated as collocated. </td>
      </tr>
      <tr>
        <td><code>-ORBCollocationStrategy</code> <em>thru_poa/direct</em>
        </td>
        <td>Specifies what type of collocated object to use. If the <code>thru_poa</code>
(default) strategy is used, TAO uses the collocation object
implementation that respects POA's current state and policies. When
using the <code>direct</code> strategy, method invocations on
collocated objects become direct calls to servant without checking
POA's status, which can increase performance. If you use the <code>direct</code>
strategy, your interfaces must be compiled with the <code><a
 href="compiler.html#collocation-stubs">-Gd</a></code> IDL <a
 href="compiler.html">compiler option</a>. </td>
      </tr>
      <tr>
        <td><code>-ORBNodelay</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBNodelay"></a>Enable or disable the <code>TCP_NODELAY</code>
option (Nagle's algorithm). By default, <code>TCP_NODELAY</code> is
enabled.</td>
      </tr>
      <tr>
        <td><code>-ORBRcvSock</code> <em>receive buffer size</em></td>
        <td><a name="-ORBRcvSock"></a>Specify the size of the socket
receive buffer as a positive, non-zero integer. If not specified, the <code>ACE_DEFAULT_MAX_SOCKET_BUFSIZ</code>
default is used.</td>
      </tr>
      <tr>
        <td><code>-ORBSndSock</code> <em>send buffer size</em></td>
        <td><a name="-ORBSndSock"></a>Specify the size of the socket
send buffer as a positive, non-zero integer. If not specified, the <code>ACE_DEFAULT_MAX_SOCKET_BUFSIZ</code>
default is used.</td>
      </tr>
      <tr>
        <td><code>-ORBStdProfileComponents</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBStdProfileComponents"></a>If <em>0</em> then
the ORB does not generate the OMG standardized profile components, such
as the ORB type and code sets. Notice that the presence of this
components is optional in GIOP 1.1 The default value is controlled by a
compile-time flag defined in <CODE>orbconf.h</CODE>.</td>
      </tr>
      <tr>
        <td><code>-ORBNegotiateCodesets</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBNegotiateCodesets"></a>If <em>0</em> then the ORB
does not include the codeset negotiation subsystem, TAO_Codeset. This yields
a somewhat smaller runtime footprint as well as a smaller IOR. However this
also removes the ability to interoperate with ORBs on systems using
alternative character or wide charater encodings. The default value may be set
at compile time by defining <CODE>TAO_NEGOTIATE_CODESETS 0</CODE> in
<CODE>orbconf.h</CODE>. Codeset negotiation support is enabled by default in
TAO as shipped.<br> <bold>Note to static lib users</bold> In order to build
TAO statically and get the codeset negotiation feature, two additional steps
are needed to ensure the TAO_Codeset library is linked in and initalized. Add the MPC feature "negotiate_codesets=1" to the default.features file and regenerate your makefiles, and add <CODE>#include "tao/Codeset/Codeset.h"</CODE> somewhere in your application source, such as the cpp file containing your main.</td>
      </tr>
      <tr>
        <td><code>-ORBSingleReadOptimization</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBSingleReadOptimization"></a>This option
controls whether TAO's ``single read optimization'' is used when
receiving requests. If this option is disabled (<code>0</code>), the
ORB will do two reads to read a request: one reads the request header
and the other reads the request payload. If this option is enabled (<code>1</code>),
the ORB will do a read of size <code>TAO_MAXBUFSIZE</code>, hoping to
read the entire request. If more than one request is read they will be
queued up for processing later.
        <p> This option defaults to <code>1</code> because it can
provide better performance.  In the case of Real-time CORBA, however, this
option should be set to <code>0</code>. Consider the following
scenario: (1) two requests are read from one socket, (2) the additional
request is queued, and (3) the ORB uses its Reactor's notification
mechanism to wake up the follower threads. If at the same time,
however, new requests arrive on others sockets of higher priority the
lower priority queued message will be processed before the newly
arrived higher priority request since Reactor notifications are given
preferences over normal I/O, thereby causing priority inversion.</p>
        </td>
      </tr>
      <tr>
       <td><code>-ORBDisableRTCollocation</code> <em>boolean (0|1)</em></td> <td><a name="-ORBDisableRTCollocation"></a>This
       option controls whether the application wants to use or discard
       RT collocation decisions made by the RT ORB. A value of
       <CODE>1</CODE> (true) disables RT collocation decisions and falls back on the default
       collocation decisions implemented in the default ORB, which is
       useful for applications using the RT ORB and doesn't want
       to use the RT collocation decisions but fallback on the default
       decisions for better performance. The default value is
       <code>0</code> (false). </td>
       </tr>
      <tr>
        <td><code>-ORBUseLocalMemoryPool</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBUseLocalMemoryPool"></a>TAO can use a local memory pool
         to satisfy some of its needs for heap storage, as it is often more
         efficient than using the platform's default memory allocator. The local
         pool will always grow as large as necessary to satisfy memory allocations,
         but it will never shrink. This means that sometimes a process can retain
         memory that it no longer needs. If the default allocator is used then
         TAO gives memory back as soon as it is not needed which allows for better
         resource sharing at the expense of memory deallocation time.
         <p>If this option is disabled (<code>0</code>), the ORB will use the
        default allocator for the platform.</p>
         <p>If this option is enabled (<code>1</code>), the orb will use the
         local memory pool.</p>
        <p> This option defaults to the compile-time option specified by
        <code>TAO_USES_LOCAL_MEMORY_POOL</code>.</p>
        </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="CMPS">4. Connection Management and Protocol Selection</a></h4>
TAO can send and receive requests and replies using various <a
 href="pluggable_protocols">transport protocols</a>. Each protocol has
its own concept of an <a href="ORBEndpoint.html">endpoint</a>.
The following options manage connections and control protocol
selection within a TAO application.
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBDefaultInitRef</code> <em>IOR prefix</em></td>
        <td><a name="-ORBDefaultInitRef"></a>This argument allows
resolution of initial references not explicitly specified with
<CODE>-ORBInitRef</CODE>. It requires a URL prefix that, after appending a slash '/'
('|' for the UIOP pluggable protocol) and a simple object key, forms a
new URL to identify an initial object reference. The URL prefix format
currently supported is based on the standard <code>corbaloc</code>
mechanism in the CORBA <a href="INS.html">Interoperable Naming
Service. </a></td>
      </tr>
      <tr>
        <td><code>-ORBDottedDecimalAddresses</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBDottedDecimalAddresses"></a>Use the dotted
decimal notation for addresses. This option can be used to workaround
broken DNS implementations and may also reduce the time spent resolving
IP addresses.  This option is enabled (<code>1</code>) by default on
Windows since DNS is often misconfigured there.  On other platforms
this option is disabled (<code>0</code>) since domain names are
more flexible address notations for IORs.</td>
      </tr>
      <tr>
        <td><code>-ORBNoServerSideNameLookups</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBNoServerSideNameLookups"></a>Setting this to 1 will
prevent the ORB from looking up the peer's hostname when accepting an incoming
connection from a client when the above value (<code>ORBDottedDecimalAddresses</code>)
is <code>0</code>. This option is disabled (<code>0</code>) by default.</td>
      </tr>
      <tr>
        <td><code>-ORBEndpoint</code> <em>endpoint</em></td>
        <td><a name="-ORBEndpoint"></a>This option is same as the <a
        href="#-ORBListenEndpoints"><code>-ORBListenEndPoints</code></a>
        option described below. <font color="red">This option will be
        deprecated in later versions on TAO since the CORBA
        specification now defines the <code>-ORBListenEndpoints</code>
        option instead. </font> </td>
      </tr>
      <tr>
        <td><code>-ORBPreferredInterfaces</code>
        <em>"targetNetwork:localNetwork,.."</em></td>
        <td><a name="-ORBPreferredInterfaces"></a>  This option allows
    clients running on a multihomed host to pick a local
    network/interface to communicate with a remote target.
    When TAO attempts to establish a connection with a host
    matching targetNetwork, then it will use the local ip address
    matching localNetwork. Simple wildcards can be used for both
    parameters, and multiple preferred interfaces can be specified
    using comma separators. For example, for a machine with two network cards
    identified by the ip addresses 192.168.1.10 and 192.168.1.20, you can
    use -ORBPreferredInterfaces *=*10,*=*20.
    Or to force all communication on the loopback address to try to first
    use the loopback address, use -ORBPreferredInterfaces 127.0.0.1=127* .
    <em>targetNetwork</em> can use any string, and must typically match
    with the value read from an IOR.
    <em>localNetwork</em> must use a dotted decimal address, because it
    will be matched with the local ip interfaces.
        </tr>
      <tr>
        <td><code>-ORBEnforcePreferredInterfaces</code>
        <em>boolean (0|1)</em></td>
        <td><a name="-ORBEnforcePreferredInterfaces"></a> If this
            option is set to <CODE>1</CODE> (true), then TAO will only try to use the
            interfaces specified by the <CODE>-ORBPreferredInterfaces</CODE> option.
            The default is <CODE>0</CODE> (false), in which case if a connection
            cannot be made using a preferred interface, TAO will
            attempt to use the default interface (<CODE>INADDR_ANY</CODE>).
            Note: If none of the preferred interfaces apply to an outgoing connection
            then they will not be enforced.  For this option to have
            any effect, therefore, the connection through a legal preferred interface must fail.
      </tr>
      <tr>
        <td><code>-ORBKeepalive</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBKeepalive"></a>This option allows users to specify
        that the SO_KEEPALIVE option is set on TCP sockets used by IIOP.
        The default is <code>0</code> (false).
        </td>
      </tr>
      <tr>
        <td><code>-ORBDontRoute</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBDontRoute"></a>This option allows users to specify
        that the SO_DONTROUTE option is set on TCP sockets used by IIOP.
        The default is <code>0</code> (false).
        </td>
      </tr>
      <tr>
        <td><code>-ORBLingerTimeout</code> <em>timeout</em></td>
        <td><a name="-ORBLingerTimeout"></a> This option allows users to
        set the linger timeout on a TCP socket before closing it.  Hence,
        this option is only useful when using IIOP.  The
        <code>timeout</code> value can be in the range of zero to the
        maximum signed integer value for the particular platform on which
        TAO is running.
        </td>
      </tr>
      <tr>
        <td><code>-ORBListenEndpoints</code> <em>endpoint</em></td>
        <td><a name="-ORBListenEndpoints"></a> This option was
        introduced with the CORBA <a
        href="http://www.omg.org/docs/orbos/01-01-04.pdf">Object
            Reference Template</A> (ORT) specification. It instructs a
        server ORB to listen for requests on the interface specified
        by <code>endpoint</code>. When used with Real-time CORBA, the option
        specifies the endpoints that the default thread pool listens
        to.  TAO endpoints are specified using a URL style format. An
        endpoint has the form:
        <blockquote><code>protocol://V.v@addr1,...,W.w@addrN
        </code></blockquote> where <code>V.v</code> and
        <code>W.w</code> are optional protocol versions for each
        address. An example of an IIOP endpoint is:
        <blockquote><code>iiop://<i><em>hostname</em></i>:<i><em>port</em></i>
        </code></blockquote>

        Sets of endpoints may be specified using multiple
        <code>-ORBListenEndpoints</code> options or by delimiting
        endpoints with a semi-colon (;).  For example,
        <blockquote><code>-ORBListenEndpoints iiop://localhost:9999
        -ORBListenEndpoints uiop:///tmp/mylocalsock
        -ORBListenEndpoints shmiop://10002 </code></blockquote> is
        equivalent to: <blockquote><code>-ORBListenEndpoints
        'iiop://localhost:9999;uiop:///tmp/mylocalsock;shmiop://10002'
        </code></blockquote> Notice the single quotes (') in the
        latter option specification. Single quotes are needed to
        prevent the shell from interpreting text after the semi-colon
        as another command to run.  <p>If an endpoint is specified
        without an <code>addr</code> such as the following: </p>
        <blockquote><code>-ORBListenEndpoints uiop://
        -ORBListenEndpoints shmiop:// </code></blockquote> then a
        default endpoint will be created for the specified
        protocol. <p>

        Click <a href="ORBEndpoint.html"> here</a> for much more on
        how to specify endpoints.
        </td>
      </tr>
      <tr>
        <td><code>-ORBLaneEndpoint</code> <em>endpoint</em></td>
        <td><a name="-ORBLaneEndpoint"></a>This option is same as the
        <a
        href="#-ORBLaneListenEndpoints"><code>-ORBLaneListenEndPoints</code></a>
        option described below. <font color="red">This option will be
        deprecated in later versions on TAO.</font>
        </td>
      </tr>
      <tr>
        <td><code>-ORBLaneListenEndpoints</code>
        <em>thread-pool-id:thread-lane-id endpoint</em></td> <td><a
        name="-ORBLaneListenEndpoints"></a> This option allows the
        user to specify endpoints for thread pools and lanes. This
        option is only meaningful when used with Real-time CORBA and
        only makes sense when the thread pools and lanes are created in the
        same order across server incarnations.  See <a
        href="#-ORBListenEndpoints"><code>-ORBListenEndPoints</code></a>
        option on how to specify endpoints.  An example is:
        <blockquote><code>2:3 iiop://localhost:2345
        </code></blockquote> where <code>2</code> specifies the second
        thread pool created by the process and <code>3</code>
        specifies the third lane of that thread pool.  Note that
        <code>0</code> should be used for the lane when specifying
        endpoints for thread pools without lanes.

        <p>Sets of endpoints may be specified using multiple
        <code>-ORBLaneListenEndpoints</code> options or by delimiting
        endpoints with a semi-colon (;). For example,
        <blockquote><code>-ORBLaneListenEndpoints 1:4
        iiop://localhost:9999 -ORBLaneListenEndpoints 1:4
        uiop:///tmp/mylocalsock -ORBLaneListenEndpoints 1:4
        shmiop://10002 </code></blockquote> is equivalent to:
        <blockquote><code>-ORBLaneListenEndpoints 1:4
        'iiop://localhost:9999;uiop:///tmp/mylocalsock;shmiop://10002'
        </code></blockquote> Notice the single quotes (') in the
        latter option specification. Single quotes are needed to
        prevent the shell from interpreting text after the semi-colon
        as another command to run.  <p>If an endpoint is specified
        without an <code>addr</code> such as the following: </p>
        <blockquote><code>-ORBLaneListenEndpoints 2:3 uiop://
        -ORBLaneListenEndpoints 2:3 shmiop:// </code></blockquote>
        then a default endpoint will be created for the specified
        protocol.
        </td>
      </tr>
      <tr>
        <td><code>-ORBImplRepoServicePort</code> <em>portspec</em></td>
        <td>Specifies which port the Implementation Repository is
listening on for multicast requests. By default, the <code>TAO_DEFAULT_IMPLREPO_SERVER_REQUEST_PORT</code>
(10018) is used.</td>
      </tr>
      <tr>
        <td><code>-ORBInitRef</code> <em>ObjectId=IOR</em></td>
        <td><a name="-ORBInitRef"></a>Allows specification of an
arbitrary object reference for an initial service. The IOR could be in
any one of the following formats: OMG <code>IOR</code>, <code>URL</code>,
        <code>corbaloc</code> (including <code>uioploc</code>) or <code>file</code>.
        <code>corbaloc</code> is a multiple end-point IOR understood by
        <code>ORB::string_to_object()</code> and used as a
boot-strapping mechanism by the <code>ORB::resolve_initial_references()</code>.
The mappings specified through this argument override the ORB
install-time defaults. The <code>file://pathname</code> interprets the
contents of the <code>pathname</code> file as an object reference in
any of the above formats. </td>
      </tr>
      <tr>
        <td><code>-ORBMulticastDiscoveryEndpoint</code> <em>endpoint</em></td>
        <td>Specifies the <code>endpoint</code> that should be used
for locating the Naming Service through multicast. <em>endpoint</em>
is of the form <code>ip-number:port-number</code> (<em>e.g.</em>, <code>"tango.cs.wustl.edu:1234"</code>
or <code>"128.252.166.57:1234"</code>). If there is no <code>':'</code>
in the end_point it is assumed to be a port number, with the IP address
being <code>INADDR_ANY</code>. </td>
      </tr>
      <tr>
        <td><code>-ORBNameServicePort</code> <em>portspec</em></td>
        <td>Specifies which port the Naming Service is listening on for
multicast requests. By default, the <code>TAO_DEFAULT_NAME_SERVICE_REQUEST_PORT</code>
(10013) value is used.</td>
      </tr>
      <tr>
        <td> <code>-ORBTradingServicePort</code>
        <em>portspec</em></a></td>
        <td> Specifies
to which port the Trading Service is listening on for multicast
requests. By default, the <code>TAO_DEFAULT_TRADING_SERVICE_REQUEST_PORT</code>
(10016) value is used.</td>
      </tr>
      <tr>
        <td> <code>-ORBUseIMR</code> <em>boolean (0|1)</em></td>
        <td>This argument specifies that for POAs with the <code>PERSISTENT</code>
policy, that the TAO <a href="implrepo/">Implementation Repository</a>
should be used for notification of startup and shutdown and object
references should be changed to use the Implementation Repository also (N.B.
although see <code>-ORBIMREndpointsInIOR</code> below). </td>
      </tr>
      <tr>
        <td> <code>-ORBIMREndpointsInIOR</code> <em>boolean (0|1)</em></td>
        <td>This argument specifies whether, for POAs with the <code>PERSISTENT</code>
policy, the TAO <a href="implrepo/">Implementation Repository</a>
listen endpoints should be encoded into IORs when <code>-ORBUseIMR</code>
is set. The default is true. </td>
      </tr>
      <tr>
        <td><code>-ORBUseParallelConnects</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBUseParallelConnects"></a>This option allows users to
        specify the ORB attempt to connect simultaniously to all endpoints
        listed in profiles, rather than stepping through individual endpoints,
        trying and possibly failing, before moving on to the next. For this
        feature to work, the server must be using shared profiles.
        The default is <code>0</code> (false).
        </td>
      </tr>
      <tr>
        <td><code>-ORBUseSharedProfile</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBUseSharedProfile"></a>
          This option allows multiple implicit or explicit endpoints to be
          combined into a single profile for a given protocol rather than using
          multiple profiles. For IIOP in non RTCORBA environments, the CORBA
          specified tagged component <code>TAG_ALTERNATE_IIOP_ADDRESS</code> is
          used to encode the combined endpoints. Processses using RTCORBA and
          priority banded connections will continue to generate Profiles with
          <code>TAO_TAG_IIOP_ENDPOINT</code> components.
          This options is disabled by default.
        </td>
      </tr>
      <tr>
        <td><code>-ORBParallelConnectDelay</code> <em>unsigned long msec</em></td>
        <td><a name="-ORBParallelConnectDelay"></a>When using parallel
        connection attempts, this option defines the number of milliseconds to
        delay when polling previously started connection attempts. If a server
        is likely to be busy, this client side option will help avoid creating
        redundant connections that must be accepted, only to be closed a moment
        later. However, if the first reachable endpoint is far down the list,
        this option will increase the delay before that endpoint is reached.
        The default is <code>0</code>.
        </td>
      </tr>
      <tr>
        <td><code>-ORBPreferIPV6Interfaces</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBPreferIPV6Interfaces"></a>
          If option is <CODE>1</CODE> (true) it directs the default
          endpoint selector for client connections to first attempt to
          connect any IIOP endpoints from a provided IOR specifying
          IPv6 interfaces.  Only when none of these can be found or sucessfully connected IPv4
          interfaces will be tried.  The default is <CODE>0</CODE> (false).
          <p>
          This option is only available for IPv6 enabled builds of TAO (<CODE>ACE_HAS_IPV6</CODE>).
        </td>
      </tr>
      <tr>
        <td><code>-ORBConnectIPV6Only</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBConnectIPV6Only"></a>
          If this option is <CODE>1</CODE> (true) it directs a server ORB to:<br><p>
          <li>allow only IPv6 interfaces as listening endpoints</li>
          <li>encode only IPv6 interfaces in the IOR profile</li>
          <li>prevent (depending on availability of IPV6_V6ONLY socket option)
          or block IPv6 to IPv4 connections</li>
          <p>
          This option directs the default endpoint selector for client connections
          to only attempt to connect any IIOP endpoints from a provided IOR specifying
          IPv6 interfaces.  Any available IPv4 interfaces will be
              ignored.  The default setting is <CODE>0</CODE> (false).
          <p>
          This option is only available for IPv6 enabled builds of TAO (ACE_HAS_IPV6).
        </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="MO">5. Miscellaneous Options</a></h4>
Options in this category don't control the behavior of the ORB in
terms of resouces or strategies. Instead, they are helper options
provided for specific application requirements.
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBId</code> <em>orb_name</em></td>
        <td><a name="-ORBId"></a>This option allows the name of an ORB
to be set to <code>orb_name</code>. The <CODE>ORBId</CODE> will be
passed to the <CODE>CORBA::ORB_init()</CODE> method to differentiate
coexisting ORBs (when there is more than one ORB).</td>
      </tr>
      <tr>
        <td><code>-ORBServerId</code> <em>server_id</em></td>
        <td><a name="-ORBId"></a>This option allows setting a name/id
to a server to uniquely identify a server to TAO's <a href="implrepo">Implementation
Repository</a>. </td>
      </tr>
      <tr>
        <td><code>-ORBDaemon</code></td>
        <td>Specifies that the ORB should <em>daemonize</em> itself, <em>i.e.</em>,
run as a background process. This option is only meaningful on OS
platforms that support daemonization.</td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<p></p>
<hr width="25%" align="left">
<h3><a name="SVC">The Service Configurator File</a></h3>
Internally, TAO uses the <a
 href="http://www.cs.wustl.edu/%7Eschmidt/PDF/Svc-Conf.pdf">ACE Service
Configurator framework</a> to allow applications to configure the ORB
at run-time. Applications provide a file named <code>svc.conf</code>
with options that configure appropriate strategies in to the ORB. The
options enable developers to control the behavior of the factories,
strategies, and resources that the ORB uses. By default, TAO provides
the following set of factories:
<p></p>
<ol>
  <li><a href="#TRF">Default Resource and Advanced Resource Factories.</a>
This factory controls the creation of configurable resources used by
TAO's ORB core. The resource factory is responsible for constructing
and providing access to various resources used by the ORB irrespective
of whether they perform client or server roles. ORB resources include
reactors, protocol factories, message flushing strategies, connection
purging strategies and different IOR parsers.
    <p> </p>
  </li>
  <li> <a href="#TSSF">Server Strategy Factory.</a> This factory
creates various strategies of special utility to the ORB that is useful
for controlling the behavior of servers. This factory is responsible
for creating strategies useful for server objects like the concurrency
strategy and the request demultiplexing strategies used by the POA.
    <p> </p>
  </li>
  <li> <a href="#TCSF">Client Strategy Factory.</a> This factory
creates various strategies of special utility to the ORB, useful for
controlling the behavior of clients. This factory is responsible for
creating strategies useful for clients such as request multiplexing
strategies, wait strategies, connect strategies etc.
    <p></p>
  </li>
</ol>
Options specified via a <code>svc.conf</code> file can represent
either the components provided by TAO (including the
<code>Resource_Factory</code>, and the
<code>Server_Strategy_Factory</code> and
<code>Client_Strategy_Factory</code>) or customized components
developed by the users. The service configurator file
(<code>svc.conf</code>) provided by the user identifies the components
to be loaded with the required strategies for each component.
<p>A <code>svc.conf</code> file is <em><b>not</b></em> required to
run
TAO applications since TAO provides a set of default values for
strategies useful for the most common use cases, <em>i.e.</em>, the
default values are set for all options. When a TAO application calls
<code>CORBA::ORB_init()</code> it will try to find the
<code>svc.conf</code> file. If found, TAO will parse and process the
directives in the file; if not found, the default value for the
default components will be used.</p>
<hr width="25%" align="left">
<h4><a name="TRF">1. Default and Advanced Resource Factories</a></h4>
Many of TAO's ORB Core resources are fixed, including the allocators
for
the incoming and outgoing data paths, and data structures for the
various
maps and lists maintained by the ORB. There is some flexibility,
however, in the choice of a reactor, the selection of transport
protocols, choice of data flushing strategy, various forms of
connection resource management strategies and possibility of using
different IOR parsers. The resource factories supported by TAO
include the <code>Resource_Factory</code> and
<code>Advanced_Resource_Factory</code>. TAO provides defaults of these
factories, as well as the specialized resource factories described
below:
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Resource Factory</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code><a href="#TDRF">Resource Factory</a></code></td>
        <td>Unless configured otherwise, this is the default resource
factory used by the ORB.The resource factory is responsible for
creating and providing access to various resources used by the server
and client ORBs. The resources managed by this factory include creation
of acceptor and connector registries, choice of data flushing strategy,
limits for connection resource management, types of CDR buffers used
for marshalling and demarshalling data, and different IOR parsers. </td>
      </tr>
      <tr>
        <td><code><a href="#TARF">Advanced Resource Factory</a></code></td>
        <td>This factory provides more advanced configuration options
in the addition to all the features of the default resource factory.<br>
        <br>
The advanced resource factory gives more control than the default
resource factory over the type of resources used and how those
resources are accessed. In addition to the options provided by the
default resource factory, the advanced resource factory provides
options that allow selecting different reactors, choosing different
transport mechanisms and selecting the right connection purging
strategy to maintain limits on resources used. The advanced resource
factory was created to allow more advanced options while keeping the
footprint of the default resource factory small.<br>
        <br>
The advanced resource factory inherits from the default resource
factory and accepts all of its options in addition to its own. </td>
      </tr>
      <tr>
        <td><code>Qt Resource Factory</code></td>
        <td>This is a specialized resource factory providing the means
for integrating with the Qt GUI toolkit from Trolltech. </td>
      </tr>
      <tr>
        <td><code>Xt Resource Factory</code></td>
        <td>This is a specialized resource factory providing the means
for integrating with the X Window System's Xt Intrinsics toolkit. </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<p></p>
<h4><a name="TDRF">1.1. Resource_Factory</a></h4>
Typically, the above options are exercised via the service
configurator (svc.conf) file. The following line in the
<code>svc.conf</code> file (all in one line)
<p> <code>static
Resource_Factory "[list of options]"</code></p>
<p>will load the default
resource factory with the options listed within the double quotes. The
following table shows the list of possible options that can be
specified within the double quotes in the above directive. There is an <a
 href="http://cvs.doc.wustl.edu/viewcvs.cgi/TAO/tests/LongUpcalls/svc.conf?rev=HEAD">
online</a> example of how this is used in TAO.</p>
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBReactorMaskSignals</code> <em>0/1</em></td>
        <td>ACE select reactors mask signals during upcalls to the
event handlers. This is only useful if the application is going to trap
those signals and handle them in any special way. Disabling the mask
can improve performance by reducing the number of kernel level locks. </td>
      </tr>
      <tr>
        <td><code>-ORBProtocolFactory</code> <em>factory</em></td>
        <td><a name="-ORBProtocolFactory"></a>Specify which pluggable
protocol factory to load. By default, only the factory for the IIOP
protocol (<code>IIOP_Factory</code>) is loaded.
        <p>For example, if some protocol called <em><code>Foo</code></em>
whose factory was called <em><code>Foo_Factory</code></em> was
available, then it could be loaded into TAO by specifying <code>-ORBProtocolFactory
Foo_Factory</code> in the service configurator file. The <em><code>Foo</code></em>
pluggable protocol would then be available for use. </p>
        </td>
      </tr>
      <tr>
        <td><code>-ORBIORParser</code> <em>parser</em></td>
        <td><a name="-ORBIORParser"></a>Name an IOR Parser to load. IOR
Parsers are used to interpret strings passed to <code>ORB::string_to_object()</code>.
By default the ORB can handle multiple string formats, including <code>IOR:</code>,
        <code>corbaloc:</code>, <code>corbaname:</code>, and <code>file:</code>.
The application developer can <a
 href="http://cvs.doc.wustl.edu/viewcvs.cgi/*checkout*/TAO/docs/ior_parsing.html?rev=HEAD">add
new IOR formats </a>using this option. </td>
      </tr>
      <tr>
        <td><code>-ORBConnectionPurgingStrategy</code> <em>type</em></td>
        <td><a name="-ORBConnectionPurgingStrategy"></a>Opened
connections are added to the transport cache so they can be reused.
If a process continues to run and these connections are not reused,
however, the cache will continue to grow.  Before each new connection,
therefore, the cache is checked and purged if it has reached the limit
specified by the <CODE>-ORBConnectionCacheMax</CODE> option or the
system default if that option was not used. The possible values for
type are <CODE>lru</CODE>, <CODE>lfu</CODE>, <CODE>fifo</CODE>, and
<CODE>null</CODE>. The default is <CODE>lru</CODE> (least recently
used). The other options are <CODE>lfu</CODE> (least frequently used),
<CODE>fifo</CODE> (first in first out), and <CODE>null</CODE> (no
connections are purged) and are contained within the TAO Strategies
library. </td>
      </tr>
      <tr>
        <td><code>-ORBConnectionCacheMax</code> <em>limit</em></td>
        <td><a name="-ORBConnectionCacheMax"></a>The transport cache
will grow to a maximum of the specified limit. The default is system
dependent, but can be overridden at compile-time by defining the
preprocessor macro <CODE>TAO_CONNECTION_CACHE_MAXIMUM</CODE>. </td>
      </tr>
      <tr>
        <td><code>-ORBMuxedConnectionMax</code> <em>number</em></td>
        <td><a name="-ORBMuxedConnectionMax"></a>The transport cache
allows only specified number of connections-per-QoS property to be
added to connection cache. Threads not getting the connections will
wait for the connections to be released. This option is more useful for
transports using a muxed connection strategy and want control over the
number of connections that are created by the active threads. </td>
      </tr>
      <tr>
        <td><code>-ORBConnectionCachePurgePercentage</code> <em>percent</em></td>
        <td><a name="-ORBConnectionCachePurgePercentage"></a>If the
transport cache is purged, the specified percentage (20 by default) of
the total number of connections cached will be closed. </td>
      </tr>
      <tr>
        <td><code>-ORBConnectionCacheLock</code> <em>locktype</em></td>
        <td><a name="-ORBConnectionCacheLock"></a>Specify the type of
lock to be used by the Connection Cache. Possible values for lock type
are <code>thread</code>, which specifies that an inter-thread mutex is
used to guarantee exclusive access, and <code>null</code>, which
specifies that no locking be performed. The default is thread. </td>
      </tr>
      <tr>
        <td><code>-ORBCorbaObjectLock</code> <em>locktype</em></td>
        <td><a name="-ORBCorbaObjectLock"></a> Specify the type of lock
to be used by CORBA::Object. The lock is needed within the CORBA object
to synchronize the state when the same object is shared by multiple
threads. Possible values for lock type are <code>thread</code>, which
specifies that an inter-thread mutex is used to guarantee exclusive
access, and <code>null</code>, which specifies that no locking be
performed. The default is thread. The <code>null</code> lock option is
useful when there is only one thread in the system. This option can be
used to minimize the amount of memory consumed by the locks in
applications where locks are not needed. The memory growth problem gets
particularly exacerbated for applications dealing with hundreds and
thousands of objects. </td>
      </tr>
      <tr>
        <td><code>-ORBObjectKeyTableLock</code> <em>locktype</em></td>
        <td><a name="-ORBObjectKeyTableLock"></a> Specify the type of
lock to be used by the ObjectKey table. ObjectKey table keeps track of
the ObjectKeys that are generated and made available through IORs. The
table manages the life time of the object keys within the ORB through a
reference counting mechanism. Possible values for lock type are <code>thread</code>,
which specifies that an inter-thread mutex is used to guarantee
exclusive access, and <code>null</code>, which specifies that no
locking be performed. The default is thread. </td>
      </tr>
      <tr>
        <td><code>-ORBFlushingStrategy</code> <em>type</em></td>
        <td><a name="-ORBFlushingStrategy"></a>By default TAO provides
three strategies to flush queued messages. The <code>leader_follower</code>
strategy uses the Reactor and non-blocking I/O to send the outgoing
messages, this strategy participates in the Leader/Followers protocol
to synchronize access to the Reactor. The <code>reactive</code>
strategy uses the Reactor but does not take part in the
Leader/Followers protocol, thus it is better used only in single
threaded applications. Finally, the <code>blocking</code> strategy
flushes the queue as soon as it becomes "full", and blocks the thread
until all the data is sent.
        </td>
      </tr>
      <tr>
        <td><code>-ORBDropRepliesDuringShutdown</code> <em>boolean (0|1)</em></td>
        <td><a name="-ORBDropRepliesDuringShutdown"></a> Strategy to
        make the ORB wait for replies to show up even if the ORB is
        shutdown. The default is to drop replies. For example, clients
        comunicating with misbehaved servers will continue to hang if
        replies don't show up and even if the client ORB is shutdown
        from another thread. This strategy helps the ORB decide to
        wait for the replies or drop replies. Some clients may not
        want to drop replies, and may want all their requests to be
        processed until ORB::destroy () is called. Setting the value
        of this option to 0 would help with that. </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="TARF">1.2. Advanced_Resource_Factory</a></h4>
This factory is located in the <code>TAO_Strategies</code> library. It
accepts the options below as well as those described above in the
<code>Resource_Factory</code>. This factory can be loaded dynamically
using a service configurator directive of the form (all on one line):
<p><code>dynamic Advanced_Resource_Factory Service_Object
*</code><br>
<code>TAO_Strategies:_make_TAO_Advanced_Resource_Factory
() "-ORBReactorType select_st" </code></p>
<p>It can also be loaded statically by doing the following:</p>
<p></p>
<ul>
  <li>Add <code>#include "tao/Strategies/advanced_resource.h"</code>
to the file containing <code>main()</code>. </li>
  <li>Link the TAO_Strategies library into the executable. </li>
  <li>Specify a service configurator directive of the form: <code>static
Advanced_Resource_Factory "-ORBReactorType select_st"</code> </li>
</ul>
You can
omit the <code>#include</code> if you always use dynamic libraries.
<p>Loading the <code>Advanced_Resource_Factory</code> disables the
<code>Resource_Factory</code>. Any directives for the
<code>Resource_Factory</code> will have no effect (and generate
warnings telling you so). The following table lists the options that
can be provided in double quotes. An example is available <a
 href="http://cvs.doc.wustl.edu/viewcvs.cgi/TAO/performance-tests/Latency/Single_Threaded/svc.conf?rev=HEAD">online
</a> that shows how to specify this option in the svc.conf file.</p>
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code>-ORBReactorType</code> <em>which</em></td>
        <td><a name="-ORBReactorType"></a>Specify what kind of reactor
the ORB uses. The default reactor is the ACE_TP_Reactor.
        <table border="1" cellpadding="0" cellspacing="2">
          <tbody>
            <tr>
              <th><em>which</em></th>
              <th>Reactor</th>
            </tr>
            <tr>
              <td><code>select_mt</code></td>
              <td>Use the multi-thread select-based reactor.</td>
            </tr>
            <tr>
              <td><code>select_st</code></td>
              <td>Use the single-thread select-based reactor.</td>
            </tr>
            <tr>
              <td><code>wfmo</code></td>
              <td>Use the WFMO reactor (Win32 only).</td>
            </tr>
            <tr>
              <td><code>msg_wfmo</code></td>
              <td>Use the MsgWFMO reactor (Win32 only).</td>
            </tr>
            <tr>
              <td><code>tp</code></td>
              <td>Use the <code>ACE_TP_Reactor</code>, a select based
thread-pool reactor which is the default.</td>
            </tr>
          </tbody>
        </table>
        </td>
      </tr>
      <tr>
        <td><code>-ORBReactorThreadQueue</code> <em>which</em></td>
        <td><a name="-ORBReactorThreadQueue"></a>Applies only to the
<CODE>ACE_TP_Reactor</CODE>, i.e., when <code>-ORBReactorType</code> =
<code>tp</code>, and specifies the order, last-in-first-out
(<em>which</em> = <code>LIFO</code>), the default, or
first-in-first-out (<em>which</em> = <code>FIFO</code>), in which
waiting threads are selected to run by the
<CODE>ACE_Select_Reactor_Token</CODE>. </td>
      </tr>
      <tr>
        <td><code>-ORBInputCDRAllocator</code> <em>which</em></td>
        <td><a name="-ORBInputCDRAllocator"></a>Specify whether the
ORB uses locked (<em>which</em> = <code>thread</code>) or lock-free
(<em>which</em> = <code>null</code>) allocators for the incoming CDR
buffers. Though <code>null</code> should give the optimal performance;
we made the default <code>thread</code>.  TAO optimizations for octet
sequences will not work in all cases when the allocator does not have
locks (for example if the octet sequences are part of a return
value). Using locked allocators also allows the users to take
advantage of the TAO octet sequence extensions to preserve the buffer
after the upcall. </td>
      </tr>
      <tr>
        <td><code>-ORBAMHResponseHandlerAllocator</code> <em>which</em></td>
        <td><a name="-ORBAMHResponseHandlerAllocator"></a>Specify whether the ORB
uses locked (<em>which</em> = <code>thread</code>) or lock-free (<em>which</em>
= <code>null</code>) allocators for the AMH response handlers.</td>
      </tr>
      <tr>
        <td><code>-ORBAMIResponseHandlerAllocator</code> <em>which</em></td>
        <td><a name="-ORBAMIResponseHandlerAllocator"></a>Specify whether the ORB
uses locked (<em>which</em> = <code>thread</code>) or lock-free (<em>which</em>
= <code>null</code>) allocators for the AMI response handlers.</td>
      </tr>
      <tr>
        <td><code>-ORBReactorRegistry</code> <em>registry_type</em></td>
        <td><a name="-ORBReactorRegistry"></a>This option is no longer
supported. The Advanced Resource Factory will emit an error if you
attempt its use. </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="TSSF">2. Server_Strategy_Factory</a></h4>
Certain elements of the ORB relate only to a TAO server. In this
context, the server is any application that passively accepts
connection from other processes and receives requests from those other
connections. The server strategy factory is responsible for supporting
features of TAO that are specific to servers. In particular, these
include the following strategies:
<ul>
  <li> The <em>concurrency strategies</em> control the thread creation
flags and other concurrency related behaviors.
    <p></p>
  </li>
  <li> The <em>demuliplexing strategies</em> are used
to locate servants inside the POA that are responsible for handling
requests.
    <p></p>
  </li>
</ul>
TAO provides a default server strategy factory called
<code>Server_Strategy_Factory</code>
<p>Typically, the following options are set via the service
configurator
(svc.conf) file. The following line in the svc.conf file (all in one
line)</p>
<p><code>static Server_Strategy_Factory "[list of
options]"</code></p>
<p>would load all the options listed within "". An
example is available <a
 href="http://cvs.doc.wustl.edu/viewcvs.cgi/TAO/performance-tests/Latency/Single_Threaded/svc.conf?rev=HEAD">online</a>
that shows how to specify this option in the <code>svc.conf</code>
file. </p>
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><a name="orb_concurrency"><code>-ORBConcurrency</code></a> <em>which</em></td>
        <td>Specify which concurrency strategy to use. Range of values
is <code>reactive</code> for a purely Reactor-driven concurrency
strategy or <code>thread-per-connection</code> for creating a new
thread to service each connection. The default is reactive. </td>
      </tr>
      <tr>
        <td><a name="server_timeout"><code>-ORBThreadPerConnectionTimeout</code></a>
        <em>milliseconds</em></td>
        <td>In many platforms it is impossible to interrupt the server
threads created by the <code>thread-per-connection</code> model. This
is because these threads are blocked in <code>read()</code> operations
(and not in <code>select()</code>). As a workaround, the server
threads periodically poll the ORB to find out if they should shutdown.
This option controls the period of the polling, expressed in
milliseconds. Applications that do not shutdown, or that can otherwise
ensure that no server threads will be running at shutdown (for example
if all the clients terminate before the server) can disable the
polling using the magic value <code>INFINITE</code>.
        <p>If the option is not provided then the ORB uses the
compile-time flag <code>TAO_DEFAULT_THREAD_PER_CONNECTION_TIMEOUT</code>,
this flag also expresses the time in milliseconds (as a string
constant) and the magic value <code>"INFINITE"</code> can be used to
disable polling entirely. This yields a slight performance improvement
(around 1%). </p>
        </td>
      </tr>
      <tr>
        <td><code>-ORBActiveObjectMapSize</code> <em>active object map
size</em></td>
        <td>Specify the size of the active object map. If not
specified, the default value is 64.</td>
      </tr>
      <tr>
        <td><code>-ORBUseridPolicyDemuxStrategy</code> <em>user id
policy based demultiplexing strategy</em></td>
        <td>Specify the demultiplexing lookup strategy to be used with
the user id policy. The <em>demultiplexing strategy</em> can be one of
        <code>dynamic</code> or <code>linear</code>. This option
defaults to using the <code>dynamic</code> strategy. </td>
      </tr>
      <tr>
        <td><code>-ORBSystemidPolicyDemuxStrategy</code> <em>system id
policy based demultiplexing strategy</em></td>
        <td>Specify the demultiplexing lookup strategy to be used with
the system id policy. The <em>demultiplexing strategy</em> can be one
of <code>dynamic</code>, <code>linear</code>, or <code>active</code>.
This option defaults to use the <code>dynamic</code> strategy when <code>-ORBAllowReactivationOfSystemids</code>
is true, and to <code>active</code> strategy when <code>-ORBAllowReactivationOfSystemids</code>
is false. </td>
      </tr>
      <tr>
        <td><code>-ORBUniqueidPolicyReverseDemuxStrategy</code> <em>unique
id policy based reverse demultiplexing strategy</em></td>
        <td>Specify the reverse demultiplexing lookup strategy to be
used with the unique id policy. The <em>reverse demultiplexing strategy</em>
can be one of <code>dynamic</code> or <code>linear</code>. This
option defaults to using the <code>dynamic</code> strategy. </td>
      </tr>
      <tr>
        <td><code>-ORBAllowReactivationOfSystemids</code> <em>allows
reactivation of system ids</em></td>
        <td>Specify whether system ids can be reactivated, i.e., once
an id that was generated by the system has been deactivated, will the
user reactivate a new servant using the old id. If the user is not
going to use this feature, the IORs can be shortened, an extra
comparison in the critical upcall path removed, and some memory on the
server side can be saved. The <code>ORBAllowReactivationOfSystemids</code>
can be <code>0</code> or <code>1</code>. This option defaults to <code>1</code>.
        </td>
      </tr>
      <tr>
        <td><code>-ORBActiveHintInIds</code> <em>adds an active hint
in
ids</em></td>
        <td>Specify whether an active hint should be added to ids. With
active hints, ids can be found quickly. However, they lead to larger
IORs. Note that this option is disregarded <code>if
-ORBAllowReactivationOfSystemids</code> is set to <code>0</code>. The <em>-ORBActiveHintInIds</em>
can be <code>0</code> or <code>1</code>. This option defaults to <code>1</code>.
        </td>
      </tr>
      <tr>
        <td><code>-ORBPoaMapSize</code> <em>poa map size</em></td>
        <td>Specify the size of the POA map. If not specified, the
default value is 24.</td>
      </tr>
      <tr>
        <td><code>-ORBPersistentidPolicyDemuxStrategy</code> <em>persistent
id policy based demultiplexing strategy</em></td>
        <td>Specify the demultiplexing lookup strategy to be used with
the persistent id policy. The <em>demultiplexing strategy</em> can be
one of <code>dynamic</code> or <code>linear</code>. This option
defaults to using the <code>dynamic</code> strategy. </td>
      </tr>
      <tr>
        <td><code>-ORBTransientidPolicyDemuxStrategy</code> <em>transient
id policy based demultiplexing strategy</em></td>
        <td>Specify the demultiplexing lookup strategy to be used with
the transient id policy. The <em>demultiplexing strategy</em> can be
one of <code>dynamic</code>, <code>linear</code>, or <code>active</code>.
This option defaults to using the <code>active</code> strategy. </td>
      </tr>
      <tr>
        <td><code>-ORBActiveHintInPOANames</code> <em>adds an active
hint in poa names</em></td>
        <td>Specify whether an active hint should be added to POA
names. With active hints, POA names can be found quickly. However, they
lead to larger IORs. The <code>-ORBActiveHintInPOANames</code> can be <code>0</code>
or <code>1</code>. This option defaults to <code>1</code>. </td>
      </tr>
      <tr>
        <td><code>-ORBThreadFlags</code> <em>thread flags</em></td>
        <td>Specify the flags used for thread creation. Flags can be
any logical-OR combination of <code>THR_DETACHED</code>, <code>THR_BOUND</code>,
        <code>THR_NEW_LWP</code>, <code>THE_SUSPENDED</code>. The
default is <code>THR_BOUND | THR_DETACHED</code> . </td>
      </tr>
      <tr>
        <td><code>-ORBPOALock</code> <em>lock type</em></td>
        <td><a name="-ORBPOALock"></a>Specify the type of lock to be
used for POA accesses. Possible values for <em>lock type</em> are <code>thread</code>,
which specifies that an inter-thread mutex is used to guarantee
exclusive access, and <code>null</code>, which specifies that no
locking be performed. The default is <code>thread</code>.</td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<h4><a name="TCSF">3. Client_Strategy_Factory</a></h4>
Similar to the
server strategy factory, the client strategy factory supports those
elements of TAO that are specific to the behavior of clients, which
are any CORBA applications that actively establish connections, submit
requests, and perhap receive responses. The client strategy factory
provides control over several resources used by clients. TAO provides
a default client strategy factory called
<code>Client_Strategy_Factory</code>.
<p>Typically, the following options are set via the service
configurator
(<code>svc.conf</code>) file. The following line in the
<code>svc.conf</code> file (all in one line)</p>
<p><code>static
Client_Strategy_Factory "[list of options]"</code></p>
<p> would load all
the options listed within "". An example is available <a
 href="http://cvs.doc.wustl.edu/viewcvs.cgi/TAO/performance-tests/Latency/Single_Threaded/svc.conf?rev=HEAD">online</a>
that shows how to specify this option in the <code>svc.conf</code>
file.</p>
<p></p>
<blockquote>
  <p>
  <table border="2" cellpadding="0" cellspacing="2">
    <tbody>
      <tr>
        <th>Option</th>
        <th>Description</th>
      </tr>
      <tr>
        <td><code><a name="#-ORBProfileLock">-ORBProfileLock</a></code>
        <em>which</em></td>
        <td>Specify the kind of synchronization primitive for the
Profiles. Default is <em>thread</em>, which means that a regular
thread mutex is used. The second option is <em>null</em>, which means
a null lock is used. This makes sense in case of optimizations and is
allowed when no forwarding is used or only a single threaded client. </td>
      </tr>
      <tr>
        <td><code>-ORBClientConnectionHandler</code> <em>MT | ST | RW
        / MT_NOUPCALL</em><br>
        <code>-ORBWaitStrategy</code> <em>MT / ST / RW / MT_NOUPCALL
        </em>
</td>
        <td><em>Please note that these two options are synonymous and can be used interchangeably.</em>
        <p><a name="-ORBClientConnectionHandler"></a><em>ST</em> means
use the single-threaded client connection handler, i.e., the leader
follower model will not be used. However, <em>ST</em> does support
nested upcalls and handling of new requests while waiting for the reply
from a server.
        <p><em>MT</em> means use the multi-threaded client connection
handler which uses the leader follower model. This model allows the use
of multiple threads with a single Reactor. </p>
        <p><em>RW</em> selects a strategy that simply blocks in
<code>recv()</code> when waiting for a response from the server
instead of waiting in the Reactor using the Leader/Followers
pattern. The <em>RW</em> strategy only works when the application
does not have to worry about new request showing up when waiting for a
response. Further, this strategy cannot be used with Asynchronous
Method Invocation (AMI) calls and when using BiDIR GIOP.
Therefore, this strategy is appropriate
only for "pure" synchronous clients. Note that applications that
require nested upcalls are not "pure" synchronous clients. Also note that this
strategy will only affect two way calls, since there is no waiting for
one way calls. This strategy can also be used in an application that
is both a client and a server if the server side is handled by a
separate thread and the client threads are "pure" clients. </p> <p>
        <CODE>MT_NOUPCALL</CODE> <b>(EXPERIMENTAL!)</b> means use a client connection handler that
        participates in the leader-follower model like MT, but, like
        RW, does not allow handling of nested upcalls within the
        waiting thread.  Note that with this strategy it is possible
        to "run out of threads" in a thread pool, and that TAO doesn't
        grow thread pools.  Unlike RW, this does not require  <a
        href="#ORBTransportMuxStrategy">-ORBTransportMuxStrategy&nbsp;<em>EXCLUSIVE</em></a>.
<!--
I'm not sure what the affect of AMI on this option is.
-->
</p>
        <p>Default for this option is <em>MT</em>. </p>
        </td>
      </tr>

      <tr>
        <td><code>-ORBConnectionHandlerCleanup</code> <em>0 | 1</em><br>
        </td>
	<td><a name="-ORBConnectionHandlerCleanup"></a>Setting this
        option to <em>1</em> lets the ORB know that connection
        handlers setup for sending messages need to  be cleaned up
        when errors occur. This option has an  effect only for
        <em> -ORBClientConnectionHandler RW </em>. Rest of  the
        options for <em> -ORBCleintConnectionHandler </em> have been
        automatically set up for cleaning the connection
        handlers. Setting the option to <em> 1 </em> has a side
        effect of registering and unregistering the connection
        handlers with the Reactor for  every invocation, which has a
        negative impact on performance. Setting  the option to <em> 0
        </em> prevents this performance impact but leads  to problems
        outlined
 <A
 href="http://deuce.doc.wustl.edu/bugzilla/show_bug.cgi?id=2186">
 here</A> and  <a
 href="http://deuce.doc.wustl.edu/bugzilla/show_bug.cgi?id=2224">
 here</A>
        <p>Default for this option is <em>0</em>. </p>
        </td>
      </tr>

      <tr>
        <td><code>-ORBTransportMuxStrategy</code> <em>EXCLUSIVE | MUXED</em></td>
        <td><a name="ORBTransportMuxStrategy"></a><em>EXCLUSIVE</em>
means that the Transport does not multiplex requests on a connection.
At a time, there can be only one request pending on a connection.
        <p><em>MUXED</em> means that Transport multiplexes more than
one request at the same time on a connection. This option is often used
in conjunction with AMI, because multiple requests can be sent "in
bulk." </p>
        <p>Default for this option is <em>MUXED</em>. </p>
        </td>
      </tr>
      <tr>
        <td><code>-ORBConnectStrategy</code> <em>type</em></td>
        <td><a name="-ORBConnectStrategy"></a>TAO provides three
strategies to connect to remote servers. The default <em>leader_follower</em>
strategy uses the Reactor and non-blocking connects to connect and this
strategy participates in the Leader/Followers protocol to synchronize
access to the Reactor. The <em>reactive</em> strategy uses the Reactor
for non-blocking connects but does not take part in the
Leader/Followers protocol, thus it is better used only in single
threaded applications. Finally, the <em>blocked</em> strategy as the
name implies, blocks the thread until connection is complete. Some of
the protocols in TAO (such as SHMIOP and SSLIOP) can only use the <em>blocked</em>
strategy.
        </td>
      </tr>
    </tbody>
  </table>
  </p>
</blockquote>
<hr>
<p>Back to the TAO <a href="components.html">component options and tuning documentation</a>.<!--#include virtual="/~schmidt/cgi-sig.html" -->
</body>
</html>