CosEC_Multiple
------------------------------------------------------------------------
This test for the Cos Event Service has 2 executables - one for suppliers
and the other for consumers.
Both connect to a running Event Service.
To run a test manually:
1. Start one or more consumers.
2. Run a Supplier, the consumer displays the data received.
The command line parameters for the Supplier are:
-n <Name of the Event Service>,the default name is "CosEventService"
-c <event_count>, number of events to send to the CosEC.
The command line parameters for the Consumer are:
-n <Name of the Event Service>,the default name is "CosEventService"
-c <event_count>, number of events to receive from the CosEC.
------------------------------------------------------------------------
Test Scripts:
run_test.pl - Event filtering using the RtEC.
This test starts up 2 CosEC's connected to one RtEC as shown..
---------
| RtEC |
---------
|
|
________|____________
| |
____|____ ____|____
| CosEC1 | | CosEC2 |
"cosec1" _________ _________ "cosec2"
| |
_____|________ _____|_______
| | | |
consumerA supplierB consumerB supplierA
The CosEC1 (see fig.) is setup with these parameters:
# cos event service name = "cosec1"
# for ConsumerQOS: EventID = 21, SourceID = 6
# for SupplierQOS: EventID = 20, SourceID = 5
The CosEC2 (see fig.) is setup with these parameters:
# cos event service name = "cosec2"
# for ConsumerQOS: EventID = 20, SourceID = 5
# for SupplierQOS: EventID = 21, SourceID = 6
This setup configures the CosEC's such that consumerA connected to CosEC1 receives events from supplierA connected to CosEC2.
similarly, consumerB and supplierB form the other pair.
Parameters:
-e event_count, The number of events supplied by each supplier
and also the number of events that a consumer will count
before shutting down.
To execute this test, run the run_test.pl script.
------------------------------------------------------------------------
run_test2.pl: demostrates multiple consumers and suppliers connected
to one CosEC.
This test has the following params -
-e event_count, The number of events supplied by each supplier
and also the number of events that a consumer will count
before shutting down.
-c consumers, The number of consumers to connect the Event service.
-s suppliers, The number of suppliers to connect the Event service.
------------------------------------------------------------------------
|