+# DLT Demo Setup
+Back to [README.md](../README.md)
+
+In this document you will run an instance of
+dlt-daemon. It silently waits to collect and buffer log messages that are
+produced by one or multiple DLT users. You will run one of those DLT users and
+make it produce log messages that are sent to the daemon. Eventually, you launch
+a client that collects and displays these messages.
+
+*Note: We assume that you installed DLT (i.e. executed the [two optional steps
+after build](../README.md#build-and-install)). Otherwise you have to take care
+of the executable paths and explicitly state the library path.*
+
+## Run the DLT Daemon
+The DLT daemon is highly configurable but for this case the default settings are
+okay. Don't be put off by warning messages:
+```bash
+$ dlt-daemon
+[1886222.668006]~DLT~32290~NOTICE ~Starting DLT Daemon; DLT Package Version: 2.18.0 STABLE, Package Revision: v2.18.1, build on Dec 8 2020 11:11:51
+-SYSTEMD -SYSTEMD_WATCHDOG -TEST -SHM
+
+[1886222.668651]~DLT~32290~INFO ~FIFO size: 65536
+[1886222.668764]~DLT~32290~INFO ~Activate connection type: 5
+[1886222.668897]~DLT~32290~INFO ~dlt_daemon_socket_open: Socket created
+[1886222.669047]~DLT~32290~INFO ~dlt_daemon_socket_open: Listening on ip 0.0.0.0 and port: 3490
+[1886222.669159]~DLT~32290~INFO ~dlt_daemon_socket_open: Socket send queue size: 16384
+[1886222.669355]~DLT~32290~INFO ~Activate connection type: 1
+[1886222.669509]~DLT~32290~INFO ~Activate connection type: 9
+[1886222.669644]~DLT~32290~INFO ~Ringbuffer configuration: 500000/10000000/500000
+[1886222.669924]~DLT~32290~NOTICE ~Failed to open ECU Software version file.
+[1886222.670034]~DLT~32290~INFO ~Activate connection type: 6
+[1886222.670188]~DLT~32290~INFO ~Switched to buffer state for socket connections.
+[1886222.670365]~DLT~32290~WARNING ~dlt_daemon_applications_load: cannot open file /tmp/dlt-runtime-application.cfg: No such file or directory
+```
+The daemon opened a named pipe from which it is ready to read and buffer log
+messages. It also accepts connections on TCP port 3490 by clients to collect
+the messages.
+
+## Produce Log Messages
+A simulated ECU - a DLT user - will now use the DLT library to create log
+messages and send them through the named pipe for the daemon to collect. Open a
+second terminal and run
+```bash
+$ dlt-example-user -n 5 -l 3 "This is my first log message"
+Send 0 This is my first log message
+Log level changed of context TEST, LogLevel=4, TraceState=0
+Log level changed of context TS1, LogLevel=4, TraceState=0
+Log level changed of context TS2, LogLevel=4, TraceState=0
+Send 1 This is my first log message
+Client disconnected!
+Send 2 This is my first log message
+Send 3 This is my first log message
+Send 4 This is my first log message
+```
+This will send 5 (```-n 5```) identical log messages of Log-Level
+WARNING ```(-l 3)``` containing a string payload.
+
+## Read logs
+The DLT daemon now has the messages in its buffer and will keep them there until
+they are fetched. A mighty tool for receiving and processing log messages is the
+[DLT-Viewer](https://github.com/GENIVI/dlt-viewer), which also provides a
+graphical UI. For now, a simple command line client is absolutely sufficient:
+```bash
+$ dlt-receive -a localhost
+2020/04/30 12:27:14.976731 17134987 000 ECU1 DA1- DC1- control response N 1 [service(3842), ok, 02 00 00 00 00]
+2020/04/30 12:27:14.976779 17067139 000 ECU1 DA1- DC1- control response N 1 [service(3842), ok, 01 00 00 00 00]
+2020/04/30 12:27:14.976787 17067139 004 ECU1 DLTD INTM log info V 1 [Client connection #7 closed. Total Clients : 0]
+2020/04/30 12:27:14.976794 17104625 005 ECU1 DLTD INTM log info V 1 [ApplicationID 'LOG' registered for PID 5241, Description=Test Application for Logging]
+2020/04/30 12:27:14.976802 17104625 000 ECU1 DA1- DC1- control response N 1 [get_log_info, 07, 01 00 4c 4f 47 00 01 00 54 45 53 54 ff ff 18 00 54 65 73 74 20 43 6f 6e 74 65 78 74 20 66 6f 72 20 4c 6f 67 67 69 6e 67 1c 00 54 65 73 74 20 41 70 70 6c 69 63 61 74 69 6f 6e 20 66 6f 72 20 4c 6f 67 67 69 6e 67 72 65 6d 6f]
+2020/04/30 12:27:14.976823 17104625 000 ECU1 DA1- DC1- control response N 1 [get_log_info, 07, 01 00 4c 4f 47 00 01 00 54 53 31 00 ff ff 1b 00 54 65 73 74 20 43 6f 6e 74 65 78 74 31 20 66 6f 72 20 69 6e 6a 65 63 74 69 6f 6e 1c 00 54 65 73 74 20 41 70 70 6c 69 63 61 74 69 6f 6e 20 66 6f 72 20 4c 6f 67 67 69 6e 67 72 65 6d 6f]
+2020/04/30 12:27:14.976844 17104625 000 ECU1 DA1- DC1- control response N 1 [get_log_info, 07, 01 00 4c 4f 47 00 01 00 54 53 32 00 ff ff 1b 00 54 65 73 74 20 43 6f 6e 74 65 78 74 32 20 66 6f 72 20 69 6e 6a 65 63 74 69 6f 6e 1c 00 54 65 73 74 20 41 70 70 6c 69 63 61 74 69 6f 6e 20 66 6f 72 20 4c 6f 67 67 69 6e 67 72 65 6d 6f]
+2020/04/30 12:27:14.976866 17104588 000 ECU1 LOG- TEST log warn V 2 [0 This is my first log message]
+2020/04/30 12:27:14.976872 17109592 001 ECU1 LOG- TEST log warn V 2 [1 This is my first log message]
+2020/04/30 12:27:14.976880 17114599 002 ECU1 LOG- TEST log warn V 2 [2 This is my first log message]
+2020/04/30 12:27:14.976884 17119607 003 ECU1 LOG- TEST log warn V 2 [3 This is my first log message]
+2020/04/30 12:27:14.976889 17124611 004 ECU1 LOG- TEST log warn V 2 [4 This is my first log message]
+2020/04/30 12:27:14.976894 17134988 006 ECU1 DLTD INTM log info V 1 [New client connection #8 established, Total Clients : 1]
+2020/04/30 12:27:15.442016 17139641 000 ECU1 DA1- DC1- control response N 1 [service(3841), ok, 4c 4f 47 00 54 45 53 54 72 65 6d 6f]
+2020/04/30 12:27:15.442044 17139642 007 ECU1 DLTD INTM log info V 1 [Unregistered ApID 'LOG']
+```
+The client connects to the default port 3490 of localhost to collect all
+messages and interprets the payload as ASCII text (```-a```). You can see lots
+of additional messages. These are control messages to control the flow between
+client and daemon. You will learn about them later. For now, you have set up a
+basic example have seen DLT in action.
+
+You can now experiment with this setup. What happens if you start the DLT user
+first and (while the DLT user is still running) the daemon? \ No newline at end of file