| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
| |
dlt_user_log_write_*_attr() enables to writing these types, but also support
adding "attributes" for them, i.e. a "name" and a "unit".
Signed-off-by: Martin Willers <M.Willers@gmx.net>
|
|
|
|
|
| |
Signed-off-by: Felix Herrmann <fherrmann@de.adit-jv.com>
Signed-off-by: KHANH LUONG HONG DUY <khanh.luonghongduy@vn.bosch.com>
|
|
|
|
| |
Signed-off-by: Martin Willers <M.Willers@gmx.net>
|
|
|
|
|
|
|
| |
The GNU preprocessor supports naming of the variadic macro parameter,
but not preprocessors does.
Signed-off-by: Ted Lyngmo <ted@lyncon.se>
|
|
|
| |
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Two new macros are introduced so that users can use their customized
timestamps for DLT messages:
- DLT_LOG_TS(CONTEXT, LOGLEVEL, TS, ARGS ...)
- DLT_LOG_ID_TS(CONTEXT, LOGLEVEL, MSGID, TS, ARGS ...)
Detailed explanations can be found in dlt_for_developers.md.
Also a new option is added to dlt-system to use events' timestamps
from journald adapter.
Signed-off-by: Sebastian Unger <sunger@de.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|
|
|
|
|
|
| |
registration Macro and API which has option to register log level change callback along with it. This will avoid missing of initial log level change callback when daemon sends the log level change control msg during context registration
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
|
|
| |
private data as argument
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
It is possible to change the default buffer size for log message creation via
environment variable:
export DLT_LOG_MSG_BUF_LEN=<value>
Instead of using a static buffer with size of 1390 bytes, the buffer is
allocated dynamically with the specified value.The max size is restricted to approx 65k.
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
| |
The poll system call is now used in the daemon to enable DLT use in
POSIX compliant systems. Also added introduced new unregister_app macro
to avoid missing of logs in startup buffer.
Signed-off-by: Frederic Berat <fberat@de.adit-jv.com>
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
|
|
|
|
|
|
|
|
| |
The original implementation result in a compile error when DLT_PTR is used with
other macros like DLT_STRING.
This patch overcomes that problem.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
| |
This function allows an application developer to check if the DLT
LogLevel is enabled before starting any log string creation. It can be
used in application specific logging wrapper functions.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Change-Id: I4c269b12bfdeae29a4e795385cdbc54a579ba621
|
|
|
|
|
|
|
|
| |
This macro internally checks the size of a void pointer to decide if the
pointer address is sent with DLT_HEX32 or DLT_HEX64 macro.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Change-Id: Ie316ac411f2174e0760e09244d04b83c8006f55d
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
Scan findings. Renamed and cleanup further files.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
Change-Id: I304ed3dd9e327def64d9388aeb9407d74d2421a9
Signed-off-by: Sascha Philipp <sascha.philipp@continental-corporation.com>
(cherry picked from commit 21a2281b7029914a39b46ee76228eefd0351c872)
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
|
|
| |
variable displayed in hexadecimal with "0x" prefix DLT_HEX16(VAR) 16bits displayed in hexadecimal with "0x" prefix DLT_HEX32(VAR) 32bits displayed in hexadecimal with "0x" prefix DLT_HEX64(VAR) 64bits displayed in hexadecimal with "0x" prefix DLT_BIN8(VAR) 8bits variable displayed in binary with "0b" prefix DLT_BIN16(VAR) 16bits variable displayed in binary with "0b" prefix
plus typo fix
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
changed
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
originally provided by Stefan Vacek.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This is a combination of 2 commits. Original descriptions below.
[GDLT-120]: Remove dlt_queue. Only usage replace with POSIX queue.
[GDLT-120]: Improve documentation. Add a note about context having to be
pesistent thorough application lifetime.
[GDLT-120]: Add macro interface.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
incorrectly.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
|
|
|
|
| |
Check return value of dlt_user_log_write_start(_id) correctly.
Reduce the number of applications if allocation fails.
Make dlt_user_log_write_start inline
Improve error checking in dlt_user_log_write_start_id
Use databuffersize to avoid reallocations
Signed-off-by: Christian Muck <christian.muck@bmw.de>
|
|
|
|
| |
Signed-off-by: Christian Muck <christian.muck@bmw.de>
|
| |
|
| |
|
| |
|
|
|
|
| |
Added new dlt_check_library_version() function.
|
| |
|
|
|