| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
| |
-Support to send and parse periodic control messages
-add application/contexts to passive ECU list
-Refactor dlt_gateway_send_control_message
-Gateway issues with corrupted data and on demand connection
-Unit Test update
Signed-off-by: Saya Sugiura ssugiura@jp.adit-jv.com
Signed-off-by: Christoph Lipka clipka@jp.adit-jv.com
Signed-off-by: S. Hameed shameed@jp.adit-jv.com
Signed-off-by: ManikandanC Manikandan.Chockalingam@in.bosch.com
|
|
|
|
|
|
|
|
|
|
| |
- improvements and refactor key creation
- Sync strategies added
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Ravi Sankar P <ponnurangamravi.sankar@in.bosch.com>
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
| |
Prepare daemon to store applications/context information of other ECUs as well. This commit prepares the dlt-daemon to store logs from passive nodes in a logstorage device.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
|
|
| |
warning: extra tokens at end of #ifdef directive
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|
|
|
|
|
|
|
|
| |
Package compilation fails with GLIBC 2.28:
stat.h:56:8: error: redefinition of 'struct statx_timestamp'
stat.h:99:8: error: redefinition of 'struct statx'
Signed-off-by: Oleksandr Kravchuk <oleksandr.kravchuk@pelagicore.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
* dlt-control: Provision to control entire system trace status
1. support for setting trace status using wildcards for both app and context
2. support for setting entire system trace status
*This Logic is as same as for changing log level.
(SHA: a966393ad7003d02870bceffa08df5ddf4bbf864
dlt-control: Provision to control entire system log level)
* dlt-daemon: Fix control entire log level / trace status issue
In previous, dlt-control could send request to set
all log level / trace status with DLT_LOG_DEFAULT / DLT_TRACE_STATUS_DEFAULT(-1).
However, dlt-daemon could not accept these value.
This change fix this issue so that setting log level/trace status of
all registered contexts become possible.
Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
|
|
|
|
|
|
| |
dlt-daemon entered to infinite loop when set log level request with
wildcards came from dlt-control due to variable size.
Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
|
|
|
|
|
| |
Even Forcing log level and trace status of context to not exceed "ContextLogLevel" and "ContextTraceStatus" in dlt.conf file with ForceContextLogLevelAndTraceStatus = 1, the default log level is being overwritten with high value than expected by client(DLT_Viewer when default trace data request is sent ) and by dlt-control application on usage of (dlt-control -d loglevel IP_ADDRESS)
With provided patch/changes in place, when ForceContextLogLevelAndTraceStatus is enabled the requested log level is checked with ContextLogLevel and if it satisfied the daemon default loglevel gets updated.
Added a conditional checks to not to overwrite the individual contextLoglevel and ContextTracesStatus when ForceContextLogLevelAndTraceStatus is enabled in dlt.conf file and taken care of review comments.
|
|
|
|
| |
character from merge - +
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
In dlt_daemon_send_all_multiple, if the connection was broken, we closed
it before getting the next available connection. This must be avoided by
having a temporary next pointer.
The same kind of problem is valid for pointers coming from the epoll
interface. The kernel can provide back connection pointer that are not
valid any longer. Therefore, we need to use an ID instead of the pointer
value to retrieve the connections.
Signed-off-by: Frederic Berat <fberat@de.adit-jv.com>
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
| |
1. support for setting log level using wildcards for both app and context
2. support for setting entire system log level
Signed-off-by: Manikandan C <Manikandan.Chockalingam@in.bosch.com>
Change-Id: I92f8c5461903f092cd50f05f644013432940a87b
|
|
|
|
|
|
|
|
|
|
| |
The receiver structures have been removed from the dlt-daemon structure,
they are now part of the connection.
The overall usage of the receiver structrure has also been reviewed in
the daemon.
Signed-off-by: Frederic Berat <fberat@de.adit-jv.com>
Change-Id: I7cf80d79ed73bd6d4f370bb3f278d26ccc9d8d7a
|
|
|
|
|
|
|
|
| |
support long options
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Change-Id: I2bac5e48a5d210b544a96fe96dc322f28ac472fe
|
|
|
|
| |
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
|
|
|
|
|
|
|
|
| |
- feature: allow to define a default-log-level in dlt.conf (see dlt.conf for documentation)
- bugfix: make dlt_unlock_mutex not inline to fix linkage
- bugfix: initial log-level was not set correctly when no dlt-daemon was running
Signed-off-by: Stefan Vacek <stefan.vacek@intel.com>
|
|
|
|
|
|
|
|
| |
Additional:
- include sd-daemon.h if watchdog is enabled
- fix formatting for printf 64bit values
Signed-off-by: Stefan Vacek <stefan.vacek@intel.com>
|
|
|
|
|
|
|
|
|
| |
This patch enables the user to specify the ECU identifier as another
filter attribute for a Logstorage filter configuration.
This attribute is optional. If not specified, the ECUid will not be
checked during message filtering within the Logstorage component.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MultiNode allows to connect DLT Daemons running on different operating systems,
e.g. in a virtualized environment. The central component is the Gateway DLT
Daemon which connects external DLT Clients, like the DLT Viewer running on a
host computer, with Passive DLT Daemons running on nodes without a physical
connection to external DLT clients. The Gateway DLT Daemon itself acts as a
DLT client when connecting to a Passive DLT Daemon.
To use the Gateway functionality, it has to be enabled in dlt.conf:
GatewayMode = 1
All communication between passive nodes and DLT Viewer has to be send via the
Gateway node. The Gateway node forwards log messages coming from passive nodes
to all connected DLT clients. It also forwards command and control requests
coming from DLT clients to the corresponding passive node.
The Gateway DLT Daemon read a configuration file (dlt_gateway.conf) at startup
with information about Passive DLT Daemon connections. Afterwards, the
Daemon will try to connect to the passive DLT Daemons. If the connection cannot
be established after the configured timeout, the Gateway DLT Daemon will give up
connecting.
The configuration file has to contain the following information about a passive
node:
[PassiveNode1]
IPaddress = 192.168.2.35
Port = 3490
EcuID = ECU2
Connect = OnStartup
; timeout in seconds
Timeout = 10
Precondition is, that the passive node is configured with the correct ECU id,
ECU2 in this case. If the passive node sends messages with another than
configured ECU id, the Gateway DLT Daemon will shut down the connection.
It is also possible to connect to a passive DLT daemon using the
dlt-passive-node-ctrl application. In this case "Connect=OnDemand" has to be
configured in the configuration file.
To connect to PassiveNode1, "dlt-passive-node-ctrl -n ECU2 -c 1" has to be
executed.
With "dlt-passive-node-ctrl -s" the status of passive node connections can be
retrieved.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Features:
1. Offline log storage to internal and external devices (PATH based trigger)
2. File options configurable in dlt.conf
a : Appends timestamp in log file name (OfflineLogstorageTimestamp)
b : Appends delimiter in log file name (OfflineLogstorageDelimiter)
c : Wrap around value for log file count in file name (OfflineLogstorageMaxCounter)
3. Common config file parser support
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The event handling has been reworked in order to use epoll and
restructure the code.
There are 2 new structures.
The DltConnection which contains all basic connection information, like
the type, the file descriptor, and the receiver structure corresponding.
The DltEventHandler that manages the DltConnections and the associated
events.
The concept is basically the following. The daemon will create different
connections, serial connections, socket connections, fifos etc ... Each of
them will then register itself to the event handler, and give it the
ownership of this connection. From this point in time, the daemon can act
on the connections.
Once an event is triggered, the event handler will call the connection
specific callback, creates new connections when clients arrives,
and potentially destroy the connection in case of hangup.
On exit, the daemon cleanup the event handler, which leads to the
destruction of the connections.
The work there is a first step for a global restructuring. Several
modification will follow, in order to rationalize the different daemon
structures, and avoid variable and code duplication.
Signed-off-by: Frederic Berat <fberat@de.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
|
|
|
|
| |
DLT daemon improvement - parameter value range check
Adapt unit tests to check for enum return values
Changed C version to gnu99 and C++ version to gnu++0c
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
Scan findings. Renamed and cleanup further files.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
| |
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|
|
|
|
|
|
|
| |
offline trace is active
Change-Id: Ic212c4956582b18e05739d593bf5c792d60d9c00
Signed-off-by: Sascha Philipp <sascha.philipp@continental-corporation.com>
|
|
|
|
|
| |
Change-Id: Id1fe0f438161fc81c5caee3c9c9627d9ddf5dbbf
Signed-off-by: Sascha Philipp <sascha.philipp@continental-corporation.com>
|
|
|
|
|
|
| |
Change-Id: I371c1b234929fda46608f563f08cae141b97d0a9
Signed-off-by: Ralf Anton Beier <ralf.anton.beier@continental-corporation.com>
Signed-off-by: Sascha Philipp <sascha.philipp@continental-corporation.com>
|
|
|
|
| |
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
|
|
| |
lib dll to correct location on Windows. Originally from Mikko Rapeli <mikko.rapeli@bmw.de>.
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
|
|
| |
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|
|
Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
|