Commit message (Collapse)AuthorAgeFilesLines
* dlt-daemon: Not output Context un-/registration DLT message by default (#62)Yusuke Sato2018-05-231-5/+11
| | | | | | | | | | | This patch changes Context un-/registration message not to output DLT by default for the purpose of reducing trace messages. Actually dlt-daemon already sends almost same meaning control message which can show Context un-/registration([get_log_info] and [unregister_context]). These are duplicate message and should be suppressed in normal case. Only if "Verbose = 1" is set in dlt.conf, the messages are output as same as before. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* dlt-daemon: Continue to send log level / connection status even if error ↵Yusuke Sato2018-05-231-3/+3
| | | | | | | | | | | | | | | | | | occurs (#61) In previous, there was possibility that application could not get notification from dlt-daemon due to wrong error handling. (e.g.) 1. App1, App2 and App3 register App/Context 2. App2 crashes without unregistering App/Context 3. Change default log level from DLT Viewer --> App1 can receive new default log level from dlt-daemon but App3 cannot. This patch makes processing non-stop even if error occurs in below cases: - While updating log level of all registered apps - While updating default log level/ default trace status - While updating connection status between dlt-daemon and dlt-client Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* IPC: Unix socket added (#43)ManikandanChockalingam2018-05-1810-82/+272
| | | | | | | | | * IPC: Unix socket added The user can select either FIFO or UNIX socket as IPC between user library and daemon through CMakelist option. Socket path configurable for both FIFO and Unix Socket now configurable in CMake Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com> Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
* Introduce controlling entire system trace status feature from dlt-control (#57)Yusuke Sato2018-05-184-43/+244
| | | | | | | | | | | | | | | | | | | | | * dlt-control: Provision to control entire system trace status 1. support for setting trace status using wildcards for both app and context 2. support for setting entire system trace status *This Logic is as same as for changing log level. (SHA: a966393ad7003d02870bceffa08df5ddf4bbf864 dlt-control: Provision to control entire system log level) * dlt-daemon: Fix control entire log level / trace status issue In previous, dlt-control could send request to set all log level / trace status with DLT_LOG_DEFAULT / DLT_TRACE_STATUS_DEFAULT(-1). However, dlt-daemon could not accept these value. This change fix this issue so that setting log level/trace status of all registered contexts become possible. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* dlt-daemon: Lower log level of logs not to output unintentional warning (#58)Yusuke Sato2018-05-181-8/+5
| | | | | | | | | | | | | * dlt-daemon: Lower log level of several logs not to output unintentional warning Change log level of several logs from WARNING to INFO. 1. User FIFO cannot be opened because the FIFO does not exist --> This case can happen if DLT user app is one-shot 2. Runtime configuration file (dlt-runtime-application.cfg / dlt-runtime-context.cfg) cannot be opened --> This case can happen in normal use case. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* dlt-daemon: Fix infinite loop on set log level using wildcards (#55)Yusuke Sato2018-05-081-1/+1
| | | | | | dlt-daemon entered to infinite loop when set log level request with wildcards came from dlt-control due to variable size. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* dlt-daemon: Fix repeated output of marker message (#54)Yusuke Sato2018-05-081-1/+4
| | | | | | | | Marker message had been continued to output if application called dlt_log_marker() due to missing byte removing processing against marker message. Therefore the byte removing for marker message processing is added. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp>
* Fix ForceContextLogLevelAndTraceStatus handling in dlt_daemon_client.c (#50)kundatipradeep2018-04-271-4/+33
| | | | | Even Forcing log level and trace status of context to not exceed "ContextLogLevel" and "ContextTraceStatus" in dlt.conf file with ForceContextLogLevelAndTraceStatus = 1, the default log level is being overwritten with high value than expected by client(DLT_Viewer when default trace data request is sent ) and by dlt-control application on usage of (dlt-control -d loglevel IP_ADDRESS) With provided patch/changes in place, when ForceContextLogLevelAndTraceStatus is enabled the requested log level is checked with ContextLogLevel and if it satisfied the daemon default loglevel gets updated. Added a conditional checks to not to overwrite the individual contextLoglevel and ContextTracesStatus when ForceContextLogLevelAndTraceStatus is enabled in dlt.conf file and taken care of review comments.
* minor compiler warning gcc 7.x (#30)Phong Tran2018-03-291-1/+1
| | | | | | | | | | | | | | | | | | | | | | | | | | | | * Fix -Wpointer-compare of compare with null char Signed-off-by: Phong Tran <tranmanphong@gmail.com> * dlt_common: fix -Wformat-truncation of snprintf Avoid snprintf output truncation by handling return value Signed-off-by: Phong Tran <tranmanphong@gmail.com> * dlt_offline_trace: Fix Wformat-truncation of snprintf Compile with Gcc 7.x has the warning of snprintf buffer length size. Check return value of snprintf() for avoiding the warning. Signed-off-by: Phong Tran <tranmanphong@gmail.com> * dlt_common_test: Fix memleak t_dlt_message_read some resources were not free after using. Detected by running valgrind --leak-check=full ./gtest_dlt_common Signed-off-by: Phong Tran <tranmanphong@gmail.com>
* improve error reporting in dlt_daemon_socket (#41)Florian Castellane2018-02-141-14/+17
| | | | | | * improve error reporting in dlt_daemon_socket * use dlt_vlog
* fix PR #26 socket_sendreliable data_send updateChristoph Lipka2018-01-191-1/+5
| | | | | | do not update data_send in case of temporal error Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
* Prevention for occasional corrupted messages (#26)baduras2018-01-123-21/+56
| | | Prevention for occasional corrupted messages caused mostly due to system high load.
* Minor fixes: corrected typo in CMakeLists.txt - WTIH_DLT_ADAPTOR, removed ↵Stefan Badura2017-08-301-1/+1
| | | | character from merge - +
* Data stuck in receiver buffer when dlt_daemon_user_send_log_level() fails (#21)Lutz Helwing2017-08-222-10/+21
| | | | | | | | | | | | - When dlt_daemon_user_send_log_level() called in dlt_daemon_process_user_message_register_context() fails -1 was returned which caused dlt_daemon_process_user_messages() to stop processing receiver buffer. Remaining data was stuck until new data arrived over FIFO. - Make debug output of dlt_daemon_user_send_log_level() more verbose. Signed-off-by: Lutz Helwing <lutz_helwing@mentor.com>
* cmake: fix unit tests compilation with systemd (#17)Gordan Markuš2017-06-161-1/+1
| | | | | | | | | By enabling the WITH_SYSTEMD and WITH_DLT_UNIT_TESTS cmake flags the build will fail with an error due to a linking issue: ../src/daemon/libdlt_daemon.so: undefined reference to `sd_booted' collect2: error: ld returned 1 exit status Signed-off-by: Gordan Markuš <gordan.markus@pelagicore.com>
* dlt_daemon_connection_types: fix build warnings (#14)Gordan Markuš2017-05-181-1/+1
| | | | | | | | | | | | dlt-daemon/src/daemon/dlt_daemon_event_handler.c: In function ‘dlt_daemon_handle_event’: dlt-daemon/src/daemon/dlt_daemon_event_handler.c:131:30: waring: cast from pointer to integer of different size [-Wpointer-to-int-cast] DltConnectionId id = (DltConnectionId)ev->data.ptr; ^ dlt-daemon/src/daemon/dlt_daemon_event_handler.c: In function ‘dlt_connection_check_activate’: dlt-daemon/src/daemon/dlt_daemon_event_handler.c:381:27: warning: cast to pointer from integer of different size [-Wint-to-pointer-cast] ev.data.ptr = (void *)con->id; ^ Signed-off-by: Gordan Markuš <gordan.markus@pelagicore.com>
* dlt-daemon: Fix use after free potential issueFrederic Berat2017-02-015-3/+48
| | | | | | | | | | | | | In dlt_daemon_send_all_multiple, if the connection was broken, we closed it before getting the next available connection. This must be avoided by having a temporary next pointer. The same kind of problem is valid for pointers coming from the epoll interface. The kernel can provide back connection pointer that are not valid any longer. Therefore, we need to use an ID instead of the pointer value to retrieve the connections. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com> Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Event handling: Fix connection destroy bugChristoph Lipka2017-02-012-0/+8
| | | | | | | | | It might happen that an event is part of the epoll event queue that belongs to a connection which was destroyed before the event is handled. Due to this, the event handling main loop might stop and the daemon exits. This misbehavior is fixed with this patch. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* daemon: check payload length before cast to structChristoph Lipka2017-01-311-15/+66
| | | | Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Unit Test: Event handlingChristoph Lipka2016-10-244-6/+43
| | | | | | Unit tests for DLT Daemon connection and event handling Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Unit Test: MultiNodeOnkar Palkar2016-10-241-0/+10
| | | | | | Unit test for DLT MultiNode extension Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* MultiNode: Specify config file location in dlt.confChristoph Lipka2016-10-243-3/+24
| | | | Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* process user message: Fix bound handlingFrederic Berat2016-10-241-16/+99
| | | | | | | | | | | | | | | | | | | | | | | | On context and application registration, the data needs to be read in 2 parts. If the first part was at the end of the receiver buffer, it was wrongly removed whereas the complete data is not full received and therefore interpretable. This has to be fixed by not removing the data before everything is checked. Thus, while readjusting the buffer to the first found header, the offset was not properly updated. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com> Process User Messages: Fix buffer handling In case application and context registration the buffer need to be read two times. But before removing the data, the data need to be readjusted to its origin. This was missing in a previous fix. Furthermore, in case of corrupted description field, applications and contexts will be registered anyway with the dummy description "Unknown". Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Fix: dlt-daemon overwrites ECU ID even if user log message already has the ↵Yusuke Sato2016-09-231-2/+2
| | | | | | | | | | | ECU ID that is not default value dlt-daemon overwrites ECU ID even if user log message already has the ECU ID that is not default value. This phenomenon happens when application uses dlt_forward_msg(). Therefore, dlt-daemon is modified not to overwrite ECU ID if log message has already has the ECU ID. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp> Change-Id: Icbc6304e5571242bf75ff0d32cbe4b004f1d7f9d
* Add: Configuration of option of get log info response during context ↵Yusuke Sato2016-09-233-1/+12
| | | | | | | | | | registration Option of get log info response during context registration was fixed to 7. This modification enables to change that option. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp> Change-Id: Ia75f15cdb33e0bffd77c5ba71a1960e820714e61
* Add: Configuration of daemon FIFO sizeYusuke Sato2016-09-233-0/+32
| | | | | | | Configuration of daemon FIFO (default: /tmp/dlt) size is added to dlt.conf. Signed-off-by: Yusuke Sato <yusuke-sato@apn.alpine.co.jp> Change-Id: I05cc56b9a05e4c3a0a1af49c374f35ae10f4674d
* dlt-daemon: Free DltDaemon structure on exitChristoph Lipka2016-04-281-3/+2
| | | | | Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com> Change-Id: I504664fa8d2a4c6d9449a1911bf139dfe6005d76
* dlt-control: Provision to control entire system log levelManikandan C2016-04-284-25/+184
| | | | | | | | 1. support for setting log level using wildcards for both app and context 2. support for setting entire system log level Signed-off-by: Manikandan C <Manikandan.Chockalingam@in.bosch.com> Change-Id: I92f8c5461903f092cd50f05f644013432940a87b
* dlt-daemon: Fix user log handler return valueFrederic Berat2016-04-281-8/+8
| | | | | | | | The user log message handler was returning 1 instead of -1 in case of failure, which was not expected. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com> Change-Id: Id03b2879f631e804f9939a9f52132be26491f888
* dlt-daemon: Connection activation reworkFrederic Berat2016-04-284-28/+119
| | | | | | | | The activation of the connection is now centralized in one common function. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com> Change-Id: I86703eab411088905a85f526d5102875e2c92b7e
* dlt-daemon: receiver reworkFrederic Berat2016-04-286-736/+702
| | | | | | | | | | The receiver structures have been removed from the dlt-daemon structure, they are now part of the connection. The overall usage of the receiver structrure has also been reviewed in the daemon. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com> Change-Id: I7cf80d79ed73bd6d4f370bb3f278d26ccc9d8d7a
* Fix connection handling of serial interfaceManikandan C2016-04-281-2/+2
| | | | | | | | Incremented client connections in case of serial connection also Signed-off-by: Manikandan C <Manikandan.Chockalingam@in.bosch.com> Change-Id: I3eb56ca67d46a7474cb750769c65c6548d40554f
* Offline logstorage: On Demand triggering for syncing Logstorage cache and ↵Christoph Lipka2016-04-253-3/+151
| | | | | | | | support long options Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com> Change-Id: I2bac5e48a5d210b544a96fe96dc322f28ac472fe
* Offline logstorage: Fixed extended header size check conditionS. Hameed2016-04-251-3/+1
| | | | | | Signed-off-by: S. Hameed <shameed@jp.adit-jv.com> Change-Id: I4466364e6340c526c8ce6f22d80c3ffc1b8be4ef
* dlt-daemon: Fix injection message handlingS. Hameed2015-12-161-1/+1
| | | | Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
* Set default log-levels in dlt.confStefan Vacek2015-12-097-31/+110
| | | | | | | | - feature: allow to define a default-log-level in dlt.conf (see dlt.conf for documentation) - bugfix: make dlt_unlock_mutex not inline to fix linkage - bugfix: initial log-level was not set correctly when no dlt-daemon was running Signed-off-by: Stefan Vacek <stefan.vacek@intel.com>
* Fix register context before application is registeredStefan Vacek2015-12-081-0/+4
| | | | | | | | Additional: - include sd-daemon.h if watchdog is enabled - fix formatting for printf 64bit values Signed-off-by: Stefan Vacek <stefan.vacek@intel.com>
* dlt-daemon: Make IP version compile time configurableS. Hameed2015-12-071-0/+4
| | | | | | Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com> Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
* MultiNode: Logstorage: ECUid as filter attributeChristoph Lipka2015-12-073-35/+45
| | | | | | | | | This patch enables the user to specify the ECU identifier as another filter attribute for a Logstorage filter configuration. This attribute is optional. If not specified, the ECUid will not be checked during message filtering within the Logstorage component. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Dlt MultiNodeChristoph Lipka2015-12-0710-146/+539
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | MultiNode allows to connect DLT Daemons running on different operating systems, e.g. in a virtualized environment. The central component is the Gateway DLT Daemon which connects external DLT Clients, like the DLT Viewer running on a host computer, with Passive DLT Daemons running on nodes without a physical connection to external DLT clients. The Gateway DLT Daemon itself acts as a DLT client when connecting to a Passive DLT Daemon. To use the Gateway functionality, it has to be enabled in dlt.conf: GatewayMode = 1 All communication between passive nodes and DLT Viewer has to be send via the Gateway node. The Gateway node forwards log messages coming from passive nodes to all connected DLT clients. It also forwards command and control requests coming from DLT clients to the corresponding passive node. The Gateway DLT Daemon read a configuration file (dlt_gateway.conf) at startup with information about Passive DLT Daemon connections. Afterwards, the Daemon will try to connect to the passive DLT Daemons. If the connection cannot be established after the configured timeout, the Gateway DLT Daemon will give up connecting. The configuration file has to contain the following information about a passive node: [PassiveNode1] IPaddress = 192.168.2.35 Port = 3490 EcuID = ECU2 Connect = OnStartup ; timeout in seconds Timeout = 10 Precondition is, that the passive node is configured with the correct ECU id, ECU2 in this case. If the passive node sends messages with another than configured ECU id, the Gateway DLT Daemon will shut down the connection. It is also possible to connect to a passive DLT daemon using the dlt-passive-node-ctrl application. In this case "Connect=OnDemand" has to be configured in the configuration file. To connect to PassiveNode1, "dlt-passive-node-ctrl -n ECU2 -c 1" has to be executed. With "dlt-passive-node-ctrl -s" the status of passive node connections can be retrieved. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Fix daemon shutdownChristoph Lipka2015-11-242-8/+31
| | | | | | | | | The shutdown of the daemon was not proper implemented. This commit fixes: - memory leaks - removal of created sockets Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* DltLogstorage: Logstorage CacheChristoph Lipka2015-11-246-7/+79
| | | | | | | | | | | | | | | | | | When using DltLogstorage on internal storage device, it is needed to reduce writing to internal storage device as much as possible. This patch introduces sync strategies to Logstorage to provide that functionality. The ON_MSG strategy is the default sync strategy that flushes every written log message to the storage device (fflush). The ON_DAEMON_EXIT strategy only flushes data to disk when the daemon exits. The strategy can be defined per filter in the dlt_logstorage.conf configuration file by adding SyncBehavior=<Strategy> to a configuration. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Offline logstorage: Offline logstorage featureS. Hameed2015-11-246-33/+185
| | | | | | | | | | | | | | Features: 1. Offline log storage to internal and external devices (PATH based trigger) 2. File options configurable in dlt.conf a : Appends timestamp in log file name (OfflineLogstorageTimestamp) b : Appends delimiter in log file name (OfflineLogstorageDelimiter) c : Wrap around value for log file count in file name (OfflineLogstorageMaxCounter) 3. Common config file parser support Signed-off-by: S. Hameed <shameed@jp.adit-jv.com> Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Unix socket control interfaceChristoph Lipka2015-11-249-5/+375
| | | | | | | | | | | | | | | | Control applications running in the same Linux OS should be able to communicate with the DLT Daemon via a socket connection. To be able to do that, the DLT Client library need to be extended. DLT Clients connected via this UNIX socket are not handled as normal DLT Clients and no log messages will be forwarded to them. This avoids problems in situations when a control application is connected to the DLT Daemon before any other 'real' DLT Client (e.g. DLT Viewer) is connected. In this situations, all already stored log messages are flushed to the control application and therefore lost, because the control application most likely ignore all incoming messages besides the one in which it is interested in. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* Parse INI filesChristoph Lipka2015-11-241-1/+1
| | | | | | | | | Offline Logstorage, Multinode and potentially other DLT extensions retrieve their configuration from a configuration file in INI file format. To avoid code duplications, this helper functionality should be used to read configuration files. Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
* offline trace: supported trace file name configuration based on indexManikandan C2015-11-183-1/+15
| | | | | | | | | Changes made for trace file name configuration based on index and made it configurable from dlt.conf file. Using this configuration one can select either timestamp based or index based log file creation for offline trace. Signed-off-by: Manikandan C <Manikandan.Chockalingam@in.bosch.com>
* dlt-daemon: Implement epoll based event handlingFrederic Berat2015-11-1111-345/+1550
| | | | | | | | | | | | | | | | | | | | | | | | | | | The event handling has been reworked in order to use epoll and restructure the code. There are 2 new structures. The DltConnection which contains all basic connection information, like the type, the file descriptor, and the receiver structure corresponding. The DltEventHandler that manages the DltConnections and the associated events. The concept is basically the following. The daemon will create different connections, serial connections, socket connections, fifos etc ... Each of them will then register itself to the event handler, and give it the ownership of this connection. From this point in time, the daemon can act on the connections. Once an event is triggered, the event handler will call the connection specific callback, creates new connections when clients arrives, and potentially destroy the connection in case of hangup. On exit, the daemon cleanup the event handler, which leads to the destruction of the connections. The work there is a first step for a global restructuring. Several modification will follow, in order to rationalize the different daemon structures, and avoid variable and code duplication. Signed-off-by: Frederic Berat <fberat@de.adit-jv.com>
* Got rid of warnings from some older compilersLutz Helwing2015-10-281-1/+1
| | | | Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
* DLT daemon improvement - dlt_init()-checkLutz Helwing2015-10-077-1301/+1287
| | | | | | | | | | DLT daemon improvement - parameter value range check Adapt unit tests to check for enum return values Changed C version to gnu99 and C++ version to gnu++0c Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>
* Fixed INTERNAL-mode connection bug in dlt-daemonSven Hassler2015-10-071-1/+1
| | | | | | | | | | | When logging-mode of the DLT-daemon was set to DLT_USER_MODE_INTERNAL or DLT_USER_MODE_OFF and a client tried to connect to the daemon, the socket for accepting new connections would be closed. This would make connecting to the daemon impossible, even if the logging mode was reset to DLT_USER_MODE_EXTERNAL or DLT_USER_MODE_BOTH. Fixed this by removing conditional check on the logging mode - clients connections are always accepted now. If the logging-mode is being switched from INTERNAL to EXTERNAL or BOTH while a client is connected, the client will then start to receive messages normally. Signed-off-by: Alexander Wenzel <Alexander.AW.Wenzel@bmw.de>