| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
| |
While allocating new memory for record of newest file name,
it is mistake to not point to the last element of list.
So the total size of list was only 2 at all.
Solution: must reserve the last pointer in order the newest file
list is updated correctly.
Signed-off-by: Bui Nguyen Quoc Thanh <thanh.buinguyenquoc@vn.bosch.com>
|
|
|
|
|
|
|
|
| |
In case cached-based strategy is used, the information of
newest log file must be updated everytime of synchronization
to file.
Signed-off-by: Bui Nguyen Quoc Thanh <thanh.buinguyenquoc@vn.bosch.com>
|
|
|
|
|
|
|
| |
- In case sync is not ON_MSG, the newest file information
does not need to be updated.
Signed-off-by: Bui Nguyen Quoc Thanh <thanh.buinguyenquoc@vn.bosch.com>
|
|
|
|
|
|
| |
- Fix wrong allocation of memory while preparing table
Signed-off-by: Bui Nguyen Quoc Thanh <thanh.buinguyenquoc@vn.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
- In case there are several filters in config dlt_logstorage.conf
which are sharing the same file name, the dlt-daemon could not handle
to write the dlt messages at the proper file. It means the latest dlt
messages might be not written into the newest file.
- In order to resolve this, dlt-daemon must keep the newest file for
each filename. Everytime new dlt message is going to be written,
dlt-daemon must ensure that it must be written out to the newest file.
Signed-off-by: Bui Nguyen Quoc Thanh <thanh.buinguyenquoc@vn.bosch.com>
Signed-off-by: KHANH LUONG HONG DUY <khanh.luonghongduy@vn.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
There is a missing NULL check for APID and CTID in
dlt_logstorage_create_keys() function in following condition:
- APID is wildcard
- CTID is wildcard
- ECUID is set
Related commit:
557624f SOPL-8567: daemon: logstorage with wildcards
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
In the current implementation, if FILTER section is setting
wildcard for both "LogAppName" and "ContextName", it will be ignored.
But it is still a valid configuration for NON-VERBOSE.
In order to consolidate the daemon's behavior, the combination of wildcard
for both "LogAppName" and "ContextName" in FILTER section will be treated
as only ECUID is specified.
Signed-off-by: Bui Nguyen Quoc Thanh <Thanh.BuiNguyenQuoc@vn.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
When following filter is used, dlt-daemon gives an error message even
it's using optional sections:
NON-VERBOSE-STORAGE-FILTER
NON-VERBOSE-LOGLEVEL-CTRL
This commit fixes to check if the section is optional or not and just
gives debug message if it's optional. Also, new static function is
introduced to harmonize all the behavior in logstorage filter.
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
dlt_offline_logstorage.c
- Parameter to isdigit is not correct
- Handle the size of memset() and strncpy() properly
dlt-test-stress-user.c
- Parameter d is duplicated
dlt_env_ll.c
- Parameter env is used before NULL check
- Remove redundant line
dlt-control-common.c
dlt_daemon_event_handler.c
- Do not use NULL variable to print log
dlt_config_file_parser.c
- Remove unnecessary loop
dlt_daemon_client.c
- Return error in NULL check
dlt_user.c
- Free allocated memory in error case
Related commit: 5c8f88d logstorage: fix compile error
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
|
|
|
| |
The variables used for application id and context id are aligned with
"apid" and "ctid".
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
|
|
| |
use default config path relative to CONFIGURATION_FILES_DIR
Signed-off-by: Vo Trung Chi <Chi.VoTrung@vn.bosch.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
This commit fixes couple of unexpected behavior on Logstorage sync behavior.
- A log file is created only if necessary to avoid creating an empty log file.
- The cache is synced with the condition:
1) When the ring buffer is not wrapped around, the cache is synced from
last sync offset to current offset
2) When the ring buffer is wrapped around for first time and current offset
is smaller than last sync offset, the cache is synced from last sync
offset to end sync offset, and then from beginning to current offset
3) Otherwise, the cache is synced from offset where the log message starts
to end sync offset, and then from beginning to current offset
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Rootcause:
The dlt-daemon rotates files for each key, but not for each [FILTER] because
dlt-daemon creates the DltLogStorageFilterConfig for each key (CTXT: or APPID: or APPID:CTXTID)
then added to the DltLogStorageFilterList.
And each DltLogStorageFilterConfig has it's own records (The list of files
that was recorded in the offline logstorage directory), that's why one [FILTER] might be
has multiple records and then its lead to the problem.
Solution:
Instead of creating the DltLogStorageFilterConfig for each key, dlt-daemon will create
the DltLogStorageFilterConfig for each [FILTER] and DltLogStorageFilterConfig has an information
of all the keys in this [FILTER].
Signed-off-by: Vo Trung Chi <Chi.VoTrung@vn.bosch.com>
|
|
|
|
| |
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|
|
|
|
| |
Signed-off-by: Manikandan C <mchockalingam@de.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
| |
Gateway
Logstorage
Event Handler
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Aditya Paluri <venkataaditya.paluri@in.bosch.com>
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
| |
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
|
|
|
|
|
|
|
|
|
|
| |
- improvements and refactor key creation
- Sync strategies added
Signed-off-by: ManikandanC <Manikandan.Chockalingam@in.bosch.com>
Signed-off-by: Saya Sugiura <ssugiura@jp.adit-jv.com>
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Ravi Sankar P <ponnurangamravi.sankar@in.bosch.com>
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
| |
support long options
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Change-Id: I2bac5e48a5d210b544a96fe96dc322f28ac472fe
|
|
|
|
|
|
| |
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Change-Id: I6d4e893b0d2d76edf6235040ffd215a9305b7a22
|
|
|
|
|
|
|
|
| |
properties
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Change-Id: I52c70f051c407e7b7e0281b1f48cdaf2f9dc5a47
|
|
|
|
|
|
|
|
|
|
|
|
| |
- double free SIGSEGV caused by uninitialized free'd value in case
of uncomplete Logstorage filter configuration
- load configuratation returns error when the last configuration is
invalid, but previous configurations are valid which results in
memory leaks
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
Change-Id: I44103ed6b17e4b02eb35bdb575c234ff12bb5208
|
|
|
|
|
|
| |
dlt_user_cfg.h
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
| |
This patch enables the user to specify the ECU identifier as another
filter attribute for a Logstorage filter configuration.
This attribute is optional. If not specified, the ECUid will not be
checked during message filtering within the Logstorage component.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When using DltLogstorage on internal storage device, it is needed to
reduce writing to internal storage device as much as possible.
This patch introduces sync strategies to Logstorage to provide that
functionality.
The ON_MSG strategy is the default sync strategy that flushes every
written log message to the storage device (fflush).
The ON_DAEMON_EXIT strategy only flushes data to disk when the daemon
exits.
The strategy can be defined per filter in the dlt_logstorage.conf
configuration file by adding
SyncBehavior=<Strategy> to a configuration.
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Features:
1. Offline log storage to internal and external devices (PATH based trigger)
2. File options configurable in dlt.conf
a : Appends timestamp in log file name (OfflineLogstorageTimestamp)
b : Appends delimiter in log file name (OfflineLogstorageDelimiter)
c : Wrap around value for log file count in file name (OfflineLogstorageMaxCounter)
3. Common config file parser support
Signed-off-by: S. Hameed <shameed@jp.adit-jv.com>
Signed-off-by: Christoph Lipka <clipka@jp.adit-jv.com>
|
|
Signed-off-by: Christoph Lipka <clipka@de.adit-jv.com>
|