PTS test results for HDP PTS version: 6.1 Tested: 08-May-2015 Android version: 5.1 Results: PASS test passed FAIL test failed INC test is inconclusive N/A test is disabled due to PICS setup ------------------------------------------------------------------------------- Test Name Result Notes ------------------------------------------------------------------------------- TC_SRC_CON_BV_01_I PASS haltest: hl register_application for instance: hl register_application health intel heartrate heartrate-monitor 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE testing when prompted: bluetooth ssp_reply for instance: bluetooth ssp_reply BT_SSP_VARIANT_CONSENT 1 Note: IUT must be discoverable, connectable TC_SRC_CON_BV_02_I PASS Note: IUT must be in discoverable mode TC_SRC_CON_BV_03_I PASS when prompted: bluetooth ssp_reply TC_SRC_CON_BV_04_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_CON_BV_05_I PASS when prompted: bluetooth ssp_reply Note: IUT must be in connectable mode TC_SRC_CON_BV_06_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_CON_BV_07_I PASS bluetooth start_discovery Note: PTS HDP device must be discovered TC_SRC_CON_BV_08_I PASS bluetooth remove_bond when prompted: bluetooth ssp_reply TC_SRC_CON_BV_09_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_CON_BV_10_I N/A TC_SRC_CC_BV_01_C PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_CC_BV_02_C PASS when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SRC_CC_BV_03_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_CC_BV_05_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SRC_CC_BV_07_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 2 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply when prompted: hl connect_channel TC_SRC_CC_BV_09_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 2 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SRC_CC_BI_12_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SRC_HCT_BV_01_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply TC_SRC_HCT_BV_02_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SRC_HCT_BV_03_I N/A TC_SRC_HCT_BV_04_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SRC_HCT_BV_05_C N/A TC_SRC_HCT_BV_06_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SRC_HCT_BV_07_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter TC_SRC_DE_BV_01_I N/A TC_SRC_DE_BV_02_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SOURCE 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SRC_DEP_BV_01_I N/A TC_SRC_DEP_BV_02_I N/A TC_SNK_CON_BV_01_I PASS haltest: hl register_application for instance: hl register_application health intel heartrate heartrate-monitor 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE testing when prompted: bluetooth ssp_reply for instance: bluetooth ssp_reply BT_SSP_VARIANT_CONSENT 1 Note: IUT must be discoverable, connectable TC_SNK_CON_BV_02_I PASS Note: IUT must be discoverable, connectable TC_SNK_CON_BV_03_I PASS when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SNK_CON_BV_04_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SNK_CON_BV_05_I PASS when prompted: bluetooth ssp_reply TC_SNK_CON_BV_06_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SNK_CON_BV_07_I PASS bluetooth start_discovery TC_SNK_CON_BV_08_I PASS bluetooth remove_bond when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SNK_CON_BV_09_I PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SNK_CON_BV_10_I N/A TC_SNK_CC_BV_01_C PASS haltest: hl connect_channel when prompted: bluetooth ssp_reply TC_SNK_CC_BV_02_C PASS when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SNK_CC_BV_04_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply TC_SNK_CC_BV_06_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 2 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter TC_SNK_CC_BV_08_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 2 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply when prompted: hl connect_channel TC_SNK_CC_BV_10_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 2 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_STREAMING pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_CC_BI_11_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_HCT_BV_01_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter hl connect_channel when prompted: bluetooth ssp_reply TC_SNK_HCT_BV_02_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_HCT_BV_03_I N/A TC_SNK_HCT_BV_04_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter when prompted: bluetooth ssp_reply Note: IUT must be discoverable, connectable TC_SNK_HCT_BV_05_C N/A TC_SNK_HCT_BV_06_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_HCT_BV_07_C PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_DE_BV_01_I N/A TC_SNK_DE_BV_02_I PASS haltest: hl register_application bluez-android Bluez bluez-hdp health-device-profile 1 BTHL_MDEP_ROLE_SINK 4100 BTHL_CHANNEL_TYPE_RELIABLE pulse-oximeter Note: IUT must be discoverable, connectable TC_SNK_DEP_BV_03_I N/A TC_SNK_DEP_BV_04_I N/A -------------------------------------------------------------------------------