summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorCloud <cloud_lin@compal.com>2017-08-08 18:02:53 +0800
committerChromeOS Commit Bot <chromeos-commit-bot@chromium.org>2017-08-09 05:31:28 +0000
commitb35060d557c0a36f6e5c6a6265bb8bea921fabc0 (patch)
tree58df86ebd9ed70dc9124eb0ca4d8d14715f0ecf6
parentc9bf4c8ff95554bbed2c799cefcdb58134248b0a (diff)
downloadchrome-ec-b35060d557c0a36f6e5c6a6265bb8bea921fabc0.tar.gz
kefka: Keep giving charge voltage/current when wake up dead battery
LGC and BYD battery will give charge voltage 0 and charge current 0 about 5 seconds when the battery wakes up. It will cause charger stops and fail to wake up the battery. Force to give max charge voltage and precharge current after the battery wakes up to prevent the issue. BUG=b:64152371;b:64148243 BRANCH=firmware-strago-7287.B TEST=Make system with LGC/BTD to over discharge state. Make sure that we can wake up the system. Signed-off-by: Cloud Lin <cloud_lin@compal.com> Change-Id: I4b512488465c7870a2359f19bdb910b16cf673f6 Reviewed-on: https://chromium-review.googlesource.com/605409 Tested-by: Lin Cloud <cloud_lin@compal.com> Reviewed-by: YH Lin <yueherngl@chromium.org> Reviewed-by: Shawn N <shawnn@chromium.org> Commit-Queue: Lin Cloud <cloud_lin@compal.com>
-rw-r--r--board/kefka/board.h1
1 files changed, 1 insertions, 0 deletions
diff --git a/board/kefka/board.h b/board/kefka/board.h
index 9f72d1dfa9..e2da997539 100644
--- a/board/kefka/board.h
+++ b/board/kefka/board.h
@@ -72,6 +72,7 @@
#define CONFIG_CHARGER_SENSE_RESISTOR_AC 10
#define CONFIG_CHARGER_INPUT_CURRENT 3136
#define CONFIG_CHARGER_DISCHARGE_ON_AC
+#define CONFIG_BATTERY_REQUESTS_NIL_WHEN_DEAD
#define CONFIG_PWM
#define CONFIG_LED_COMMON