authormike <mike5@huaqin.corp-partner.google.com>2021-07-08 23:55:58 +0800
committerCommit Bot <commit-bot@chromium.org>2021-07-09 01:57:16 +0000
commit943646345564d20afadbb837104c962e4b335410 (patch)
tree8e450202cbc9bd995f586b0960409991cec21bfc /board
parent07096fe0c8c05e589eb4f9ff5fea7df5a94a69c3 (diff)
downloadchrome-ec-943646345564d20afadbb837104c962e4b335410.tar.gz
sasukette: modify swelling function setting
according to new spec, we modify swelling function setting BUG=b:192925456 BRANCH=dedede TEST=test department test swelling function pass Signed-off-by: mike <mike5@huaqin.corp-partner.google.com> Change-Id: Ie4f75e7d9259853d17fb50b9f6a89d0ede1da69d Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/3016135 Reviewed-by: Aseda Aboagye <aaboagye@chromium.org>
Diffstat (limited to 'board')
-rw-r--r--board/sasukette/battery.c242
1 files changed, 80 insertions, 162 deletions
diff --git a/board/sasukette/battery.c b/board/sasukette/battery.c
index 10d4187c15..652c04a651 100644
--- a/board/sasukette/battery.c
+++ b/board/sasukette/battery.c
@@ -5,9 +5,15 @@
* Battery pack vendor provided charging profile
*/
+#include "battery.h"
#include "battery_fuel_gauge.h"
+#include "battery_smart.h"
#include "charge_state.h"
#include "common.h"
+#include "util.h"
+
+#define CHARGING_VOLTAGE_MV_SAFE 8400
+#define CHARGING_CURRENT_MA_SAFE 1500
/*
* Battery info for all sasukette battery types. Note that the fields
@@ -68,180 +74,92 @@ BUILD_ASSERT(ARRAY_SIZE(board_battery_info) == BATTERY_TYPE_COUNT);
const enum battery_type DEFAULT_BATTERY_TYPE = BATTERY_SDI;
-static int swelling_flag = -1;
-static int prev_ac = -1;
-static int charger_flag = -1;
-
-enum swelling_data {
- SWELLING_TRIGGER_5 = 1,
- SWELLING_TRIGGER_15,
- SWELLING_TRIGGER_45,
- SWELLING_TRIGGER_50,
- SWELLING_RECOVERY_10,
- SWELLING_RECOVERY_20,
- SWELLING_RECOVERY_50,
- SWELLING_DATA_COUNT
-};
-
int charger_profile_override(struct charge_state_data *curr)
{
- static timestamp_t chargeCnt;
- int bat_temp_c = (curr->batt.temperature - 2731) / 10;
+ int current;
+ int voltage;
+ /* battery temp in 0.1 deg C */
+ int bat_temp_c;
+ const struct battery_info *batt_info;
/*
- * start charge temp control
+ * Keep track of battery temperature range:
*
- * if bat_temp >= 45 or bat_temp <= 0 when adapter plugging in,
- * stop charge
- * if 0 < bat_temp < 45 when adapter plugging in, charge normal
+ * ZONE_0 ZONE_1 ZONE_2 ZONE_3
+ * ---+------+--------+--------+------+--- Temperature (C)
+ * 0 5 12 45 50
*/
- if (curr->ac != prev_ac) {
- if (curr->ac) {
- if ((bat_temp_c <= 0) || (bat_temp_c >= 45))
- charger_flag = 1;
- }
- prev_ac = curr->ac;
- }
-
- if (charger_flag) {
- curr->requested_current = 0;
- curr->requested_voltage = 0;
- curr->batt.flags &= ~BATT_FLAG_WANT_CHARGE;
- curr->state = ST_IDLE;
- }
-
- if ((bat_temp_c > 0) && (bat_temp_c < 45))
- charger_flag = 0;
-
-/*
- * battery swelling control
- *
- * trigger condition | recovery condition
- * 1. bat_temp < 5 && | 1.batt_temp >= 10
- * bat_cell_voltage < 4.15 |
- * | cv = (cell CV-50mv)*series
- * cv = 4150mv*series = 8300mv | = 8700mv
- * cc = FCC*C_rate*0.4 | cc = FCC*C_rate*0.4 = 1464ma
- * |
- * 2. bat_temp < 15 && | 2.batt_temp >= 20,
- * bat_cell_voltage < 4.15 |
- * | cv = (cell CV-50mv)*series
- * cv = 4150mv*series = 8300mv | = 8700mv
- * cc = FCC*C_rate*0.4= 1464ma | cc = FCC*C_rate*0.9 = 3294ma
- * |
- * 3. bat_temp >= 45 && | 3. batt_temp < 43
- * bat_cell_voltage < 4.15 |
- * | cv = (cell CV-50mv)*series
- * cv = 4150mv*series = 8300mv | = 8700mv
- * cc = FCC*C_rate*0.45= 1647ma | cc = FCC*C_rate*0.9 = 3294ma
- * |
- * 4. bat_temp >= 50 | 4.batt_temp < 45,
- * stop charge | recovery charge
- */
- if (curr->ac && !charger_flag) {
-
- /*
- * battery swelling trigger condition
- */
- if (curr->batt.voltage < 8300) {
- if (bat_temp_c < 5)
- swelling_flag = SWELLING_TRIGGER_5;
- else if (bat_temp_c < 15)
- swelling_flag = SWELLING_TRIGGER_15;
-
- if (bat_temp_c >= 50)
- swelling_flag = SWELLING_TRIGGER_50;
- else if (bat_temp_c >= 45) {
- if (!(swelling_flag & SWELLING_TRIGGER_50))
- swelling_flag = SWELLING_TRIGGER_45;
- }
- }
-
- /*
- * battery swelling recovery condition
- */
- if (swelling_flag) {
- if ((bat_temp_c >= 10) && (bat_temp_c < 20))
- swelling_flag = SWELLING_RECOVERY_10;
- else if ((bat_temp_c >= 20) && (bat_temp_c < 43))
- swelling_flag = SWELLING_RECOVERY_20;
- else if ((bat_temp_c >= 43) && (bat_temp_c < 45))
- swelling_flag = SWELLING_RECOVERY_50;
- }
-
- switch (swelling_flag) {
- case SWELLING_TRIGGER_5:
- curr->requested_voltage = 4150 * 2;
- curr->requested_current = 5230 * 0.7 * 0.4;
-
- if ((curr->batt.current < 300)) {
- if (chargeCnt.val == 0) {
- chargeCnt.val = get_time().val
- + 30 * SECOND;
- } else if (timestamp_expired(chargeCnt, NULL)) {
- curr->requested_current = 0;
- curr->requested_voltage = 0;
- curr->batt.flags &=
- ~BATT_FLAG_WANT_CHARGE;
- curr->state = ST_IDLE;
- }
- } else {
- chargeCnt.val = 0;
- }
- break;
+ enum {
+ TEMP_ZONE_0, /* 0 <= bat_temp_c <= 5 */
+ TEMP_ZONE_1, /* 5 < bat_temp_c <= 12 */
+ TEMP_ZONE_2, /* 12 < bat_temp_c <= 45 */
+ TEMP_ZONE_3, /* 45 < bat_temp_c <= 50 */
+ TEMP_ZONE_COUNT,
+ TEMP_OUT_OF_RANGE = TEMP_ZONE_COUNT
+ } temp_zone;
- case SWELLING_TRIGGER_15:
- curr->requested_current = 5230 * 0.7 * 0.4;
- chargeCnt.val = 0;
- break;
+ /*
+ * Precharge must be executed when communication is failed on
+ * dead battery.
+ */
+ if (!(curr->batt.flags & BATT_FLAG_RESPONSIVE))
+ return 0;
- case SWELLING_TRIGGER_45:
- curr->requested_voltage = 4150 * 2;
- curr->requested_current = 5230 * 0.7 * 0.45;
+ current = curr->requested_current;
+ voltage = curr->requested_voltage;
+ bat_temp_c = curr->batt.temperature - 2731;
+ batt_info = battery_get_info();
- if ((curr->batt.current < 300)) {
- if (chargeCnt.val == 0) {
- chargeCnt.val = get_time().val
- + 30 * SECOND;
- } else if (timestamp_expired(chargeCnt, NULL)) {
- curr->requested_current = 0;
- curr->requested_voltage = 0;
- curr->batt.flags &=
- ~BATT_FLAG_WANT_CHARGE;
- curr->state = ST_IDLE;
- }
- } else {
- chargeCnt.val = 0;
- }
- break;
-
- case SWELLING_TRIGGER_50:
- curr->requested_current = 0;
- curr->requested_voltage = 0;
- curr->batt.flags &= ~BATT_FLAG_WANT_CHARGE;
+ /*
+ * If the temperature reading is bad, assume the temperature
+ * is out of allowable range.
+ */
+ if ((curr->batt.flags & BATT_FLAG_BAD_TEMPERATURE) ||
+ (bat_temp_c < 0) || (bat_temp_c > 500))
+ temp_zone = TEMP_OUT_OF_RANGE;
+ else if (bat_temp_c <= 50)
+ temp_zone = TEMP_ZONE_0;
+ else if (bat_temp_c <= 120)
+ temp_zone = TEMP_ZONE_1;
+ else if (bat_temp_c <= 450)
+ temp_zone = TEMP_ZONE_2;
+ else
+ temp_zone = TEMP_ZONE_3;
+
+ switch (temp_zone) {
+ case TEMP_ZONE_0:
+ voltage = CHARGING_VOLTAGE_MV_SAFE;
+ current = CHARGING_CURRENT_MA_SAFE;
+ break;
+
+ case TEMP_ZONE_1:
+ voltage += 100;
+ current = CHARGING_CURRENT_MA_SAFE;
+ break;
+
+ case TEMP_ZONE_2:
+ voltage += 100;
+ break;
+
+ case TEMP_ZONE_3:
+ voltage = CHARGING_VOLTAGE_MV_SAFE;
+ break;
+
+ case TEMP_OUT_OF_RANGE:
+ /* Don't charge if outside of allowable temperature range */
+ current = 0;
+ voltage = 0;
+ curr->batt.flags &= ~BATT_FLAG_WANT_CHARGE;
+ if (curr->state != ST_DISCHARGE)
curr->state = ST_IDLE;
- chargeCnt.val = 0;
- break;
-
- case SWELLING_RECOVERY_10:
- curr->requested_current = 5230 * 0.7 * 0.4;
- chargeCnt.val = 0;
- break;
+ break;
+ }
- case SWELLING_RECOVERY_20:
- case SWELLING_RECOVERY_50:
- curr->requested_current = 5230 * 0.7 * 0.9;
- chargeCnt.val = 0;
- break;
+ if (voltage > batt_info->voltage_max)
+ voltage = batt_info->voltage_max;
- default:
- curr->requested_voltage += 100;
- break;
- }
- } else {
- swelling_flag = 0;
- chargeCnt.val = 0;
- }
+ curr->requested_voltage = voltage;
+ curr->requested_current = MIN(curr->requested_current, current);
return 0;
}