Prevent power on with disconnected battery
Currently, if a battery is disconnected but reporting a charge
percentage over CONFIG_CHARGER_MIN_BAT_PCT_FOR_POWER_ON_WITH_AC, a
system will be allowed to boot despite the battery not providing power
yet.
This change verifies that the battery is connected, as well as having a
high enough charge percentage before allowing boot.
BUG=b:133724948
BRANCH=octopus
TEST=verified casta can power on once
CONFIG_CHARGER_MIN_BAT_PCT_FOR_POWER_ON_WITH_AC is passed and battery is
connected
Change-Id: Ide9fe041a328bbeaeee8b9e7f9788b5731ac80ea
Signed-off-by: Diana Z <dzigterman@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/1635531
Reviewed-by: Justin TerAvest <teravest@chromium.org>
Reviewed-by: Karthikeyan Ramasubramanian <kramasub@chromium.org>
Commit-Queue: Karthikeyan Ramasubramanian <kramasub@chromium.org>
Tested-by: Karthikeyan Ramasubramanian <kramasub@chromium.org>
Legacy-Commit-Queue: Commit Bot <commit-bot@chromium.org>
Diffstat (limited to 'common')
-rw-r--r-- | common/charge_state_v2.c | 4 |
1 files changed, 4 insertions, 0 deletions
diff --git a/common/charge_state_v2.c b/common/charge_state_v2.c index e479a3164f..3ede9e19aa 100644 --- a/common/charge_state_v2.c +++ b/common/charge_state_v2.c @@ -2036,6 +2036,10 @@ int charge_prevent_power_on(int power_button_pressed) defined(CONFIG_CHARGER_MIN_BAT_PCT_FOR_POWER_ON_WITH_AC) else if (charge_manager_get_power_limit_uw() >= CONFIG_CHARGER_MIN_POWER_MW_FOR_POWER_ON_WITH_BATT * 1000 +#ifdef CONFIG_BATTERY_REVIVE_DISCONNECT + && battery_get_disconnect_state() == + BATTERY_NOT_DISCONNECTED +#endif && (current_batt_params->state_of_charge >= CONFIG_CHARGER_MIN_BAT_PCT_FOR_POWER_ON_WITH_AC)) prevent_power_on = 0; |