summaryrefslogtreecommitdiff
path: root/driver/accel_kxcj9.h
diff options
context:
space:
mode:
authorAlec Berg <alecaberg@chromium.org>2014-03-24 10:03:56 -0700
committerchrome-internal-fetch <chrome-internal-fetch@google.com>2014-04-05 03:25:47 +0000
commit529548208cad436232cfba2c0b802523ddaf5383 (patch)
tree74e7b6febda2d30599ab72204befc8d61e0c3d7c /driver/accel_kxcj9.h
parentf06ad7e2ab4fa1a03c2e48a8bca3fdf2abbdffa9 (diff)
downloadchrome-ec-529548208cad436232cfba2c0b802523ddaf5383.tar.gz
accel: add host command to modify accel params and add ectool command
Created a host command to set/get various motion sensor parameters and added an ectool command to use that host command. The host command is created such that the first argument is a sub-command. Sub-commands created include: dump: dumps all current motion sensor data info: returns general information about each motion sensor ec_rate: set/get the EC sampling rate of sensors sensor_range: set/get the sensor range (ie +/- 2G,4G,8G) sensor_odr: set/get the sensor output data rate (ie 50Hz, 100Hz, ...) For sensor_range and sensor_odr parameters, since the host doesn't know what are valid values for the parameter, the host can specify to round up or down to the nearest valid value. For example, the host can specify to set the output data rate to at least 100Hz, and the EC will return the closest valid output data rate that is at least 100Hz. BUG=chrome-os-partner:27321 BRANCH=rambi TEST=Test on a glimmer using ectool from vt-2 prompt: > ectool motionsense help Usage: motionsense - dump all motion data motionsense info NUM - print sensor info motionsense ec_rate [RATE_MS] - set/get sample rate motionsense odr NUM [ODR [ROUNDUP]] - set/get sensor ODR motionsense range NUM [RANGE [ROUNDUP]]- set/get sensor range > > ectool motionsense Sensor 0: 0, 0, 1024 Sensor 1: 1024, 0, 0 Sensor 2: None > ectool motionsense info 0 Type: accel Location: base Chip: kxcj9 > ectool motionsense ec_rate 10 > ectool motionsense ec_rate 1000 1000 > ectool motionsense odr 0 100000 > ectool motionsense odr 0 40000 1 50000 > ectool motionsense range 0 8 8 After running this I verified on the EC console that all the parameters were set appropriately. I tested the EC sampling rate was 1000ms by running lidangle on and making sure samples were displayed roughly every second. I verified the sensor odr and range by defining CONFIG_CMD_ACCELS and typing: > accelrange 0 8 > accelrate 0 50000 Change-Id: I444e2f0eafabd607f1c7aa78b5c4e91f6cb06387 Signed-off-by: Alec Berg <alecaberg@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/192064 Reviewed-on: https://chromium-review.googlesource.com/193307 Reviewed-by: Randall Spangler <rspangler@chromium.org>
Diffstat (limited to 'driver/accel_kxcj9.h')
-rw-r--r--driver/accel_kxcj9.h30
1 files changed, 0 insertions, 30 deletions
diff --git a/driver/accel_kxcj9.h b/driver/accel_kxcj9.h
index a7137326d9..ea15b6ec17 100644
--- a/driver/accel_kxcj9.h
+++ b/driver/accel_kxcj9.h
@@ -100,36 +100,6 @@
#define KXCJ9_OSA_1600_HZ 7
-/**
- * Write the accelerometer range.
- *
- * @param id Target accelerometer
- * @param range Range (KXCJ9_GSEL_*).
- *
- * @return EC_SUCCESS if successful, non-zero if error.
- */
-int accel_write_range(const enum accel_id id, const int range);
-
-/**
- * Write the accelerometer resolution.
- *
- * @param id Target accelerometer
- * @param range Resolution (KXCJ9_RES_*).
- *
- * @return EC_SUCCESS if successful, non-zero if error.
- */
-int accel_write_resolution(const enum accel_id id, const int res);
-
-/**
- * Write the accelerometer data rate.
- *
- * @param id Target accelerometer
- * @param range Data rate (KXCJ9_OSA_*).
- *
- * @return EC_SUCCESS if successful, non-zero if error.
- */
-int accel_write_datarate(const enum accel_id id, const int rate);
-
#ifdef CONFIG_ACCEL_INTERRUPTS
/**
* Setup a one-time accel interrupt. If the threshold is low enough, the