diff options
author | wangganxiang <wangganxiang@huaqin.corp-partner.google.com> | 2023-05-09 16:23:21 +0800 |
---|---|---|
committer | Chromeos LUCI <chromeos-scoped@luci-project-accounts.iam.gserviceaccount.com> | 2023-05-15 08:19:45 +0000 |
commit | e89f731318700b04bc3d4872d88223d97c2e0270 (patch) | |
tree | 8f2ed8bf02a516c361e8c2164c2437e2c6f8736d /driver/ppc/rt1739.c | |
parent | 926f0b68e18c4fc5c8ed48efe2bb7640cb8a391c (diff) | |
download | chrome-ec-e89f731318700b04bc3d4872d88223d97c2e0270.tar.gz |
starmie: Improve RT1739 dead battery voltage issue
Add RT1739 initialization during EC boot.
This modification is optimized for dead battery voltage issues.
BUG=b:281606949
TEST=zmake build starmie
The board can power on normally under AC only mode.
Change-Id: I1843b9bce231bc730ad1c4ccb69d74fe3d7beb65
Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/4516061
Reviewed-by: Mike Lee <mike5@huaqin.corp-partner.google.com>
Commit-Queue: Ganxiang Wang <wangganxiang@huaqin.corp-partner.google.com>
Reviewed-by: Sung-Chi Li <lschyi@chromium.org>
Tested-by: Ganxiang Wang <wangganxiang@huaqin.corp-partner.google.com>
Diffstat (limited to 'driver/ppc/rt1739.c')
-rw-r--r-- | driver/ppc/rt1739.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/driver/ppc/rt1739.c b/driver/ppc/rt1739.c index ffd7760986..4679290b67 100644 --- a/driver/ppc/rt1739.c +++ b/driver/ppc/rt1739.c @@ -273,7 +273,7 @@ static int rt1739_set_vbus_source_current_limit(int port, enum tcpc_rp_value rp) return write_reg(port, RT1739_REG_VBUS_OC_SETTING, reg); } -static int rt1739_init(int port) +int rt1739_init(int port) { int device_id, oc_setting, sys_ctrl, vbus_switch_ctrl; bool batt_connected = false; |