diff options
author | Jett Rink <jettrink@chromium.org> | 2018-05-23 16:17:17 -0600 |
---|---|---|
committer | chrome-bot <chrome-bot@chromium.org> | 2018-05-24 19:30:22 -0700 |
commit | ae82b79667d227d58675cbf73fa032d6bead098f (patch) | |
tree | d39466baa1d4c3e60f62e42e5cb0783ba20cec84 /test | |
parent | 15bddb51eb5b61cd2b5aaeffecf64d4851a4fb9f (diff) | |
download | chrome-ec-ae82b79667d227d58675cbf73fa032d6bead098f.tar.gz |
sn5s330: disable under voltage protection
We need to disable under voltage protection because it prevents us from
enabling the sink path when there is not Vbus on the connector side. We
need to enable the sink path before we hibernate otherwise there is no
power power to get to the charger which will then assert ACOK. Without
this we won't wake up with the ACOK wake when USB power is inserted.
BRANCH=none
BUG=b:79948623
TEST=bip wakes with USB power insertion
Change-Id: Idf16a92dacde63cf943ef68b0258b320d11de44c
Signed-off-by: Jett Rink <jettrink@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/1070867
Reviewed-by: Aaron Durbin <adurbin@chromium.org>
Reviewed-by: Furquan Shaikh <furquan@chromium.org>
Diffstat (limited to 'test')
0 files changed, 0 insertions, 0 deletions