fan: Enable fan control on AP startup not on shutdown/suspend
There is no need to cool CPU in S3 or S5. We currently don't have fans
for a charging system (i.e. a battery or a charger chip).
Battery management systems control charge current based on its own
temperature readings. Thus, we do not need to keep fans running in S3/S5.
Even with a fan for a charging system, it's questionable to run a fan in
S3/S5. Under a heated condition, spinning a fan would create more heat
as a fan draws current from a battery and the ambient air is hot.
With this patch, EC disables fan control when entering S3/S5 (though fan
control would be already disabled if DPTF is used). It also makes EC
enables fan control when AP starts (for BIOS and OS if DPTF isn't used).
Signee-off-by: Daisuke Nojiri <dnojiri@chromium.org>
BUG=none
BRANCH=none
TEST=Verify fan spins in S0 and stops in S3/S5. Fan is controled by EC
in BIOS and by DPTF in OS after warm and cold reboot.
Run make run-fan.
Change-Id: Idb4610303e65f7fd4d6b24a0dfe511cd629bf6a7
Reviewed-on: https://chromium-review.googlesource.com/1138822
Commit-Ready: ChromeOS CL Exonerator Bot <chromiumos-cl-exonerator@appspot.gserviceaccount.com>
Tested-by: Daisuke Nojiri <dnojiri@chromium.org>
Reviewed-by: Daisuke Nojiri <dnojiri@chromium.org>
Diffstat (limited to 'test')
-rw-r--r-- | test/fan.c | 4 |
1 files changed, 4 insertions, 0 deletions
diff --git a/test/fan.c b/test/fan.c index 6082de1553..c5e4c32fd8 100644 --- a/test/fan.c +++ b/test/fan.c @@ -22,6 +22,8 @@ /*****************************************************************************/ /* Tests */ +void set_thermal_control_enabled(int fan, int enable); + static int test_fan(void) { /* "actual" fan speed from board/host/fan.c */ @@ -32,6 +34,8 @@ static int test_fan(void) /* With nothing else to do, fans default to full-on */ TEST_ASSERT(fan_get_rpm_actual(0) == FAN_RPM(0)->rpm_max); + set_thermal_control_enabled(0, 1); + /* * fan_set_percent_needed() is normally called once a second by the * thermal task, but we're not using a thermal test in this test so |