| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When battery is full and system is not in S0, then stop charging
and allow battery to power the system. Once battery is no longer
full and requests current, allow charging again. This is to work
around power consumption issues in our AC input path. The charge
override port is stored upon entering S3 and restored going back
to S0 so that the charge override port is not affected by this.
This also fixes lightbar so lightbar checks if battery is full
instead of checking raw percentage. The lightbar is also changed
to use the last tap direction if no charger is plugged in. And
the lightbar tap for battery threshold for turning green is
lowered to 95%.
This also moves some samus_pd board code out of interrupt handlers
and in to deferred functions to minimize time in interrupts.
BUG=chrome-os-partner:34640, chrome-os-partner:34847
BRANCH=samus
TEST=load onto samus. use battfake command from pd console to
set battery percentage. when system is in G3, see that
batt = 100% stops charging, and when batt < 100% it starts
charging again.
tested that we receive host command from EC with battery
information every time battery changes SOC.
Change-Id: Ia8e0721508e34ee3630f5e5b0c2f431a00329caf
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/236411
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Modify board_set_active_charge_port to return status indicating whether
the selected charge port was rejected. If rejected, zero out its
available charge and attempt to select a different charge port.
Also, reduce the length of related console prints.
BUG=chrome-os-partner:34677
TEST=Manual on Samus. Plug C-to-Arec into port 1, verify that charge
manager does not select port 1 as active and charging icon is not seen
in OS.
BRANCH=Samus.
Change-Id: I56e3337f90c04b93ef7cc9873af6ee0f4b1ffc7d
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/236361
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
If override charge is selected on a port currently acting as a charge
source, but the attached device is also capable of acting as a source,
request a charge role swap and initiate a pending delayed port override.
If the role swap completes successfully and a charge source is found,
the selected port will become the override port. If the role swap fails
or no charge source is found within 2 seconds, the delayed port override
will be lost.
BUG=chrome-os-partner:28343,chrome-os-partner:31195
TEST=Manual on Samus. Connect two Samus units together through charge
ports.
"pd 1 swap power" - put port on test device into source role
"chgoverride 1" - set charge override, verify that role swap takes
effect and charge manager selects PD charge source, 900mA @ 5V
Disconnect charge cable, verify that charge manager goes back to not
charging.
BRANCH=Samus
Change-Id: Iadcc4dc98631661f254245eeff18973df517f652
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/231900
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Add host command to set charge port override.
BUG=chrome-os-partner:32003
BRANCH=Samus
TEST=Manual on Samus. Insert PD charger in port1 and BC1.2 charger in
port0.
./ectool --name=cros_pd chargeoverride 0 --> Charges from port 0
./ectool --name=cros_pd chargeoverride off --> Charges from port 1
./ectool --name=cros_pd chargeoverride dontcharge --> No charge port
./ectool --name=cros_pd chargeoverride 1 --> Charges from port 1
./ectool --name=cros_pd chargeoverride 2 --> Correctly returns error
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Change-Id: Ib35f797a4a24e96fd2e3c008ace3fd6291b89d25
Reviewed-on: https://chromium-review.googlesource.com/230910
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Allow a charge port to be selected as the override port, which means it
will always be selected as the charge port, if any charge supplier is
available.
BUG=chrome-os-partner:32003
TEST=Attach PD charger and BC1.2 charger. Verify that active charge port
switches to BC1.2 after running `chargeoverride [port]` from console.
Also, pass unit tests.
BRANCH=Samus
Change-Id: Ia1b48ca89641842d51be7eed3b92d36d3eedc9ef
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/227730
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
When a PD charger is detected, gets its max charge capability, but
initially negotiate for its minimum charge mode. If we later determine
that the port will be the one active charge port, re-negotiate for the
max charge capability.
BUG=chrome-os-partner:32003
TEST=Manual on Samus. Plug in Zinger, verify that current limit is
initially set to 500 mA, then switches to 3000 mA shortly after. Plug in
two Zingers, verify that one provides 3000 mA current while the other
negotiates to 500 mA. Verify that the 500 mA charger bumps up to a high
current once becoming active.
BRANCH=Samus
Change-Id: Ifa562b72d763642fc8bd62bc7f5aaa4eda1ef950
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/225922
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Allow the list of charge suppliers and port selection priority to be
specified at the board level.
BUG=chrome-os-partner:32650
TEST=Manual on samus_pd. Plug + unplug PD and BC1.2 chargers, verify
that PD is always preferred and higher power port / supplier is always
selected.
BRANCH=Samus
Change-Id: Ic867a40120c809111bf76bf290ed6f204eab1168
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/225292
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|
|
charge_manager is intended to manage charge limits from various tasks
(typically PD charge tasks and USB / BC 1.2 charge tasks). These tasks
can update the charge limit of a port by calling charge_manager_update
(thread-safe function). If the charge limit has changed,
charge_manager_refresh will be queued as a deferred task, which will
select the "best" charge port and set the proper charge limit.
In order to use charge_manager, a board needs to do the following:
1. Declare PD_PORT_COUNT in usb_pd_config.h
2. Implement board_set_charge_limit
3. Implement board_set_active_charge_port
4. Call charge_manager_update whenever the available charge on a port changes.
BUG=chrome-os-partner:31361
TEST=Manual on samus_pd, with subsequent commit. Insert and remove
various chargers, check console to verify PD charger always has priority
and correct current limit is set based upon 'best' charger.
BRANCH=samus
Change-Id: Iede120b69e0b46ed329bcf9b7e07c39ba5e9f77b
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/222723
Reviewed-by: Alec Berg <alecaberg@chromium.org>
|