summaryrefslogtreecommitdiff
path: root/include/device_state.h
Commit message (Collapse)AuthorAgeFilesLines
* cr50: notify chipset hooks when the AP state changesMary Ruthven2016-09-221-7/+1
| | | | | | | | | | | | | | | | | | | | | Cr50 monitors UART1 RX to sense the state of the AP. This signal can be used to tell if it is in S0. If the signal is pulled up then the AP is on. If it is not pulled up then the AP is not in S0. This change notifies HOOK_CHIPSET_SUSPEND when UART1 RX is not pulled up, and then notifies HOOK_CHIPSET_RESUME when the signal is high again. The AP usb can be disabled during suspend, so this change changes the hook that triggers disabling the AP usb to be attached to HOOK_CHIPSET_SUSPEND instead of HOOK_CHIPSET_RESUME. BUG=chrome-os-partner:55747 BRANCH=none TEST=buildall Change-Id: I47fb38a4bbcd72424ec2535d61e87f820cf1bcd7 Signed-off-by: Mary Ruthven <mruthven@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/383978 Reviewed-by: Bill Richardson <wfrichar@chromium.org>
* cr50: remove unused detect_off interruptMary Ruthven2016-09-211-2/+1
| | | | | | | | | | | | | | | | The interrupts to detect when the falling edge on the UART signals are currently disabled and never reenabled. Power off is detected by polling and not through interrupts. This change removes all of those falling edge interrupts. BUG=none BRANCH=none TEST=cr50 can detect when the EC, AP, and Servo are off or on Change-Id: I0fd8a0d970f3235b26af6b90dd395ea7c75e0c17 Signed-off-by: Mary Ruthven <mruthven@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/385192 Reviewed-by: Bill Richardson <wfrichar@chromium.org>
* cr50: disable device monitoring when not in ccdMary Ruthven2016-07-121-4/+20
| | | | | | | | | | | | | | | When cr50 is not trying to do ccd, we dont need to monitor the devices. Disable device state detection interrupts and the AP and EC UARTs. BUG=none BRANCH=none TEST=gru and kevin monitor devices correctly when ccd is enabled, and dont monitor anything when it is disabled. Change-Id: Ic3f5974320486ff6dd0147c490a1c294cc2f6a76 Signed-off-by: Mary Ruthven <mruthven@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/356770 Reviewed-by: Aseda Aboagye <aaboagye@chromium.org>
* cr50: monitor the state of Servo, the EC, and APMary Ruthven2016-05-271-0/+36
There are a couple of issues that cr50 has when it cannot know the state of servo, the EC, and the AP. This change adds support so we can detect when the AP or EC has been powered on and when servo has been connected. It uses the UART RX signals to monitor the power state of the AP and EC. The TX signals are used to monitor the state of servo. BUG=chrome-os-partner:52056,chrome-os-partner:52322 BRANCH=none TEST=verify device states are correct when the AP and EC are powered on or off and when Servo is attached or detached Change-Id: Id0a2281b65cb367ecc8d0ca2f9a576672318a5fb Signed-off-by: Mary Ruthven <mruthven@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/344019