From 78b79fe3445710a0c3f134bcbd726921aada8a28 Mon Sep 17 00:00:00 2001 From: Seunghwan Kim Date: Fri, 29 Jan 2021 08:07:40 +0900 Subject: celes : override charging voltage & current change charging voltage & current for safety BUG=b:277799022 BRANCH=None TEST=make -j BOARD=celes Change-Id: I9537a9c61be53f0ae2b78cceb5e052ec04635221 Signed-off-by: Seunghwan Kim Reviewed-on: https://chromium-review.googlesource.com/c/chromiumos/platform/ec/+/4413759 Reviewed-by: Ybha - Reviewed-by: Aseda Aboagye Tested-by: Ybha - Commit-Queue: YH Lin Reviewed-by: YH Lin Reviewed-by: Henry Sun --- board/celes/battery.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/board/celes/battery.c b/board/celes/battery.c index dfbde519d4..f26c96d54b 100644 --- a/board/celes/battery.c +++ b/board/celes/battery.c @@ -14,8 +14,8 @@ /* Shutdown mode parameter to write to manufacturer access register */ #define SB_SHUTDOWN_DATA 0x0010 -#define CHARGING_VOLTAGE_LIMIT 8500 -#define CHARGING_CURRENT_LIMIT 1930 +#define CHARGING_VOLTAGE_LIMIT 8304 +#define CHARGING_CURRENT_LIMIT 1536 static const struct battery_info info = { .voltage_max = 8700,/* mV */ -- cgit v1.2.1