summaryrefslogtreecommitdiff
path: root/zephyr/dts/bindings/temp/temp_sensor.yaml
blob: b96e9c3262908699ad36a5b3f20c7d538f8a27e6 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
# Copyright 2021 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.

# Common properties for temperature sensors
# Zero values in degrees K(-273 in degrees C)in thermal thresholds will
# be ignored

properties:
    label:
      required: true
      type: string
      description:
        Human-readable string describing the device (used as
        device_get_binding() argument)

    temp_fan_off:
      required: false
      type: int
      default: -273
      description:
        Temperature threshold in degrees C when no active cooling
        is needed

    temp_fan_max:
      required: false
      type: int
      default: -273
      description:
        Temperature threshold in degrees C when max active cooling
        is needed

    temp_host_warn:
      required: false
      type: int
      default: -273
      description:
        Temperature threshold in degrees C of thermal warn.
        Temperatures above the thermal warn threshold generate a
        request to the AP to throttle itself.

    temp_host_high:
      required: false
      type: int
      default: -273
      description:
        Temperature threshold in degrees C of thermal high.
        Temperatures above the thermal high threshold cause the EC to
        assert a signal (usually PROCHOT) to the AP and force the AP to
        throttle.

    temp_host_halt:
      required: false
      type: int
      default: -273
      description:
        Temperature threshold in degrees C that forces AP to shutdown
        due to thermal reason

    temp_host_release_warn:
      required: false
      type: int
      default: -273
      description:
        Temperature release threshold in degrees C of thermal warn

    temp_host_release_high:
      required: false
      type: int
      default: -273
      description:
        Temperature release threshold in degrees C of thermal high

    temp_host_release_halt:
      required: false
      type: int
      default: -273
      description:
        Temperature release threshold in degrees C of thermal shutdown