# Copyright 2021 The Chromium OS Authors. All rights reserved.
# Use of this source code is governed by a BSD-style license that can be
# found in the LICENSE file.
# Common properties for temperature sensors
# Zero values in degrees K(-273 in degrees C)in thermal thresholds will
# be ignored
properties:
label:
required: true
type: string
description:
Human-readable string describing the device (used as
device_get_binding() argument)
temp_fan_off:
required: false
type: int
default: -273
description:
Temperature threshold in degrees C when no active cooling
is needed
temp_fan_max:
required: false
type: int
default: -273
description:
Temperature threshold in degrees C when max active cooling
is needed
temp_host_warn:
required: false
type: int
default: -273
description:
Temperature threshold in degrees C of thermal warn.
Temperatures above the thermal warn threshold generate a
request to the AP to throttle itself.
temp_host_high:
required: false
type: int
default: -273
description:
Temperature threshold in degrees C of thermal high.
Temperatures above the thermal high threshold cause the EC to
assert a signal (usually PROCHOT) to the AP and force the AP to
throttle.
temp_host_halt:
required: false
type: int
default: -273
description:
Temperature threshold in degrees C that forces AP to shutdown
due to thermal reason
temp_host_release_warn:
required: false
type: int
default: -273
description:
Temperature release threshold in degrees C of thermal warn
temp_host_release_high:
required: false
type: int
default: -273
description:
Temperature release threshold in degrees C of thermal high
temp_host_release_halt:
required: false
type: int
default: -273
description:
Temperature release threshold in degrees C of thermal shutdown
|