summaryrefslogtreecommitdiff
path: root/FreeRTOS/Demo/PPC440_DP_FPU_Xilinx_Virtex5_GCC/RTOSDemo/flop/flop-reg-test.c
blob: 0ee4da7df77946ee937e82e5156e737af8f1156b (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
/*
 * FreeRTOS Kernel V10.4.0
 * Copyright (C) 2020 Amazon.com, Inc. or its affiliates.  All Rights Reserved.
 *
 * Permission is hereby granted, free of charge, to any person obtaining a copy of
 * this software and associated documentation files (the "Software"), to deal in
 * the Software without restriction, including without limitation the rights to
 * use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of
 * the Software, and to permit persons to whom the Software is furnished to do so,
 * subject to the following conditions:
 *
 * The above copyright notice and this permission notice shall be included in all
 * copies or substantial portions of the Software.
 *
 * THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
 * IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS
 * FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR
 * COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER
 * IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN
 * CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
 *
 * http://www.FreeRTOS.org
 * http://aws.amazon.com/freertos
 *
 * 1 tab == 4 spaces!
 */

/*
 * Tests the floating point context save and restore mechanism.
 *
 * Two tasks are created - each of which is allocated a buffer of 
 * portNO_FLOP_REGISTERS_TO_SAVE 32bit variables into which the flop context
 * of the task is saved when the task is switched out, and from which the
 * flop context of the task is restored when the task is switch in.  Prior to 
 * the tasks being created each position in the two buffers is filled with a 
 * unique value - this way the flop context of each task is different.
 *
 * The two test tasks never block so are always in either the Running or
 * Ready state.  They execute at the lowest priority so will get pre-empted
 * regularly, although the yield frequently so will not get much execution
 * time.  The lack of execution time is not a problem as its only the 
 * switching in and out that is being tested.
 *
 * Whenever a task is moved from the Ready to the Running state its flop 
 * context will be loaded from the buffer, but while the task is in the
 * Running state the buffer is not used and can contain any value - in this
 * case and for test purposes the task itself clears the buffer to zero.  
 * The next time the task is moved out of the Running state into the
 * Ready state the flop context will once more get saved to the buffer - 
 * overwriting the zeros.
 *
 * Therefore whenever the task is not in the Running state its buffer contains
 * the most recent values of its floating point registers - the zeroing out
 * of the buffer while the task was executing being used to ensure the values 
 * the buffer contains are not stale.
 *
 * When neither test task is in the Running state the buffers should contain
 * the unique values allocated before the tasks were created.  If so then
 * the floating point context has been maintained.  This check is performed
 * by the 'check' task (defined in main.c) by calling 
 * xAreFlopRegisterTestsStillRunning().
 *
 * The test tasks also increment a value each time they execute.
 * xAreFlopRegisterTestsStillRunning() also checks that this value has changed
 * since it last ran to ensure the test tasks are still getting processing time.
 */

/* Standard includes files. */
#include <string.h>

/* Scheduler include files. */
#include "FreeRTOS.h"
#include "task.h"

/*-----------------------------------------------------------*/

#define flopNUMBER_OF_TASKS		2
#define flopSTART_VALUE ( 0x0000000100000001LL )

/*-----------------------------------------------------------*/

/* The two test tasks as described at the top of this file. */
static void vFlopTest1( void *pvParameters );
static void vFlopTest2( void *pvParameters );

/*-----------------------------------------------------------*/

/* Buffers into which the flop registers will be saved.  There is a buffer for 
both tasks. */
static volatile portDOUBLE dFlopRegisters[ flopNUMBER_OF_TASKS ][ portNO_FLOP_REGISTERS_TO_SAVE ];

/* Variables that are incremented by the tasks to indicate that they are still
running. */
static volatile unsigned long ulFlop1CycleCount = 0, ulFlop2CycleCount = 0;

/*-----------------------------------------------------------*/

void vStartFlopRegTests( void )
{
TaskHandle_t xTaskJustCreated;
unsigned portBASE_TYPE x, y;
portDOUBLE z = flopSTART_VALUE;

	/* Fill the arrays into which the flop registers are to be saved with 
	known values.  These are the values that will be written to the flop
	registers when the tasks start, and as the tasks do not perform any
	flop operations the values should never change.  Each position in the
	buffer contains a different value so the flop context of each task
	will be different. */
	for( x = 0; x < flopNUMBER_OF_TASKS; x++ )
	{
		for( y = 0; y < ( portNO_FLOP_REGISTERS_TO_SAVE - 1); y++ )
		{
			dFlopRegisters[ x ][ y ] = z;
			z+=flopSTART_VALUE;
		}
	}


	/* Create the first task. */
	xTaskCreate( vFlopTest1, "flop1", configMINIMAL_STACK_SIZE, NULL, tskIDLE_PRIORITY, &xTaskJustCreated );

	/* The task	tag value is a value that can be associated with a task, but 
	is not used by the scheduler itself.  Its use is down to the application so
	it makes a convenient place in this case to store the pointer to the buffer
	into which the flop context of the task will be stored.  The first created
	task uses dFlopRegisters[ 0 ], the second dFlopRegisters[ 1 ]. */
	vTaskSetApplicationTaskTag( xTaskJustCreated, ( void * ) &( dFlopRegisters[ 0 ][ 0 ] ) );

	/* Do the same for the second task. */
	xTaskCreate( vFlopTest2, "flop2", configMINIMAL_STACK_SIZE, NULL, tskIDLE_PRIORITY, &xTaskJustCreated );
	vTaskSetApplicationTaskTag( xTaskJustCreated, ( void * ) &( dFlopRegisters[ 1 ][ 0 ] ) );
}
/*-----------------------------------------------------------*/

static void vFlopTest1( void *pvParameters )
{
	/* Just to remove compiler warning. */
	( void ) pvParameters;

	for( ;; )
	{
		/* The values from the buffer should have now been written to the flop
		registers.  Clear the buffer to ensure the same values then get written
		back the next time the task runs.  Being preempted during this memset
		could cause the test to fail, hence the critical section. */
		portENTER_CRITICAL();
			memset( ( void * ) dFlopRegisters[ 0 ], 0x00, ( portNO_FLOP_REGISTERS_TO_SAVE * sizeof( portDOUBLE ) ) );
		portEXIT_CRITICAL();

		/* We don't have to do anything other than indicate that we are 
		still running. */
		ulFlop1CycleCount++;
		taskYIELD();
	}
}
/*-----------------------------------------------------------*/

static void vFlopTest2( void *pvParameters )
{
	/* Just to remove compiler warning. */
	( void ) pvParameters;

	for( ;; )
	{
		/* The values from the buffer should have now been written to the flop
		registers.  Clear the buffer to ensure the same values then get written
		back the next time the task runs. */
		portENTER_CRITICAL();
			memset( ( void * ) dFlopRegisters[ 1 ], 0x00, ( portNO_FLOP_REGISTERS_TO_SAVE * sizeof( portDOUBLE ) ) );
		portEXIT_CRITICAL();

		/* We don't have to do anything other than indicate that we are 
		still running. */
		ulFlop2CycleCount++;
		taskYIELD();
	}
}
/*-----------------------------------------------------------*/

portBASE_TYPE xAreFlopRegisterTestsStillRunning( void )
{
portBASE_TYPE xReturn = pdPASS;
unsigned portBASE_TYPE x, y;
portDOUBLE z = flopSTART_VALUE;
static unsigned long ulLastFlop1CycleCount = 0, ulLastFlop2CycleCount = 0;

	/* Called from the 'check' task.
	
	The flop tasks cannot be currently running, check their saved registers
	are as expected.  The tests tasks do not perform any flop operations so
	their registers should be as per their initial setting. */
	for( x = 0; x < flopNUMBER_OF_TASKS; x++ )
	{
		for( y = 0; y < ( portNO_FLOP_REGISTERS_TO_SAVE - 1 ); y++ )
		{
			if( dFlopRegisters[ x ][ y ] != z )
			{
				xReturn = pdFAIL;
				break;
			}

			z+=flopSTART_VALUE;
		}
	}

	/* Check both tasks have actually been swapped in and out since this function
	last executed. */
	if( ulFlop1CycleCount == ulLastFlop1CycleCount )
	{
		xReturn = pdFAIL;
	}

	if( ulFlop2CycleCount == ulLastFlop2CycleCount )
	{
		xReturn = pdFAIL;
	}

	ulLastFlop1CycleCount = ulFlop1CycleCount;
	ulLastFlop2CycleCount = ulFlop2CycleCount;

	return xReturn;
}