summaryrefslogtreecommitdiff
path: root/docs
diff options
context:
space:
mode:
authorTrevor Curtis <tcurtis@src.gnome.org>2001-09-03 05:30:21 +0000
committerTrevor Curtis <tcurtis@src.gnome.org>2001-09-03 05:30:21 +0000
commitca63f2ecd6102539418b4341698c7573ee811634 (patch)
tree8cdb56688e24b4e3a935d3d1155c8bff6399b751 /docs
parent31b49b42923d5089f901dd9bcb4bcb7c993ee539 (diff)
downloadgdm-ca63f2ecd6102539418b4341698c7573ee811634.tar.gz
Updated gdmconfig.sgml to reflect recent changes in the gui, gdmconfig.
Diffstat (limited to 'docs')
-rw-r--r--docs/gdmconfig/C/gdmconfig.sgml110
1 files changed, 97 insertions, 13 deletions
diff --git a/docs/gdmconfig/C/gdmconfig.sgml b/docs/gdmconfig/C/gdmconfig.sgml
index bb738dc4..6e9bdd1b 100644
--- a/docs/gdmconfig/C/gdmconfig.sgml
+++ b/docs/gdmconfig/C/gdmconfig.sgml
@@ -869,6 +869,36 @@
</para>
</listitem>
</varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Displays per host
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Specifies the number of displays that can run on any one host to be
+ set.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Ping interval
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Specifies the interval, in minutes, that the gdm waits between
+ issuing pings to make sure the display is still alive.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Allows the specification of a script to run to set the willing
+ headers sent by the manager.
+ </para>
+ </listitem>
+ </varlistentry>
</variablelist>
<variablelist><title>X-server setup</title>
@@ -886,18 +916,25 @@
</listitem>
</varlistentry>
<varlistentry>
- <term><guimenuitem>Server
- Definitions</guimenuitem></term>
+ <term><guimenuitem>Servers
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Displays a list of server definitions. From the buttons on the
+ right, one can create aliases for a specific server setup. Enabling
+ a server as <guimenuoption>Flexible</guimenuoptions>, indicates that
+ the server can be started on demand.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Static Servers
+ </guimenuitem></term>
<listitem>
<para>
- The local display number(s), and the command that
- needs to be run to start the X server(s). <guibutton>Add</guibutton>
- server brings up a dialog to enter X server and
- any parameters that may need to be passed. <guibutton>Edit</guibutton>
- server brings up a dialog box to edit the
- highlighted entry. <guibutton>Delete
- server</guibutton> deletes the hightlighted
- entry.
+ Allows the selection of servers which run always run. By picking
+ one of the server definitions via the buttons on the right, one can
+ setup the desired static server(s).
</para>
</listitem>
</varlistentry>
@@ -910,11 +947,58 @@
</listitem>
</varlistentry>
<varlistentry>
- <term><guimenuitem>Enable debugging
- output</guimenuitem></term>
+ <term><guimenuitem>Standard X server
+ </guimenuitem></term>
<listitem>
<para>
- Allow debugging information to be displayed
+ Indicates the X server to be used and its respective path.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Xnest server
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Indicates the Xnest server to be used and its respective path.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Maximum number of flexible servers
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Indicates the maximum number of flexible servers, that may be
+ running at any one given time.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Failsafe X server
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Indicates the Failsafe X server to be used and its respective path.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>Script to run when X is crashing
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Indicates a script to run in the event on's X session keeps crashing.
+ </para>
+ </listitem>
+ </varlistentry>
+ <varlistentry>
+ <term><guimenuitem>X configurator binaries to try
+ </guimenuitem></term>
+ <listitem>
+ <para>
+ Indicates which binaries to use when an X session, or X itself,
+ crashes.
</para>
</listitem>
</varlistentry>