diff options
author | Theodore Ts'o <tytso@mit.edu> | 2006-09-27 01:50:46 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@g5.osdl.org> | 2006-09-27 08:26:17 -0700 |
commit | 8e18e2941c53416aa219708e7dcad21fb4bd6794 (patch) | |
tree | 44118f8b09556193ac93e0b71aecfa3e1d4bc182 /fs/devpts | |
parent | 6a1d9805ec506d8b9d04450997707da5f643d87c (diff) | |
download | linux-rt-8e18e2941c53416aa219708e7dcad21fb4bd6794.tar.gz |
[PATCH] inode_diet: Replace inode.u.generic_ip with inode.i_private
The following patches reduce the size of the VFS inode structure by 28 bytes
on a UP x86. (It would be more on an x86_64 system). This is a 10% reduction
in the inode size on a UP kernel that is configured in a production mode
(i.e., with no spinlock or other debugging functions enabled; if you want to
save memory taken up by in-core inodes, the first thing you should do is
disable the debugging options; they are responsible for a huge amount of bloat
in the VFS inode structure).
This patch:
The filesystem or device-specific pointer in the inode is inside a union,
which is pretty pointless given that all 30+ users of this field have been
using the void pointer. Get rid of the union and rename it to i_private, with
a comment to explain who is allowed to use the void pointer. This is just a
cleanup, but it allows us to reuse the union 'u' for something something where
the union will actually be used.
[judith@osdl.org: powerpc build fix]
Signed-off-by: "Theodore Ts'o" <tytso@mit.edu>
Signed-off-by: Judith Lebzelter <judith@osdl.org>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
Diffstat (limited to 'fs/devpts')
-rw-r--r-- | fs/devpts/inode.c | 4 |
1 files changed, 2 insertions, 2 deletions
diff --git a/fs/devpts/inode.c b/fs/devpts/inode.c index f7aef5bb584a..5bf06a10dddf 100644 --- a/fs/devpts/inode.c +++ b/fs/devpts/inode.c @@ -177,7 +177,7 @@ int devpts_pty_new(struct tty_struct *tty) inode->i_gid = config.setgid ? config.gid : current->fsgid; inode->i_mtime = inode->i_atime = inode->i_ctime = CURRENT_TIME; init_special_inode(inode, S_IFCHR|config.mode, device); - inode->u.generic_ip = tty; + inode->i_private = tty; dentry = get_node(number); if (!IS_ERR(dentry) && !dentry->d_inode) @@ -196,7 +196,7 @@ struct tty_struct *devpts_get_tty(int number) tty = NULL; if (!IS_ERR(dentry)) { if (dentry->d_inode) - tty = dentry->d_inode->u.generic_ip; + tty = dentry->d_inode->i_private; dput(dentry); } |