diff options
author | Zdenek Kabelac <zkabelac@redhat.com> | 2015-10-12 11:35:53 +0200 |
---|---|---|
committer | Zdenek Kabelac <zkabelac@redhat.com> | 2015-10-13 15:15:43 +0200 |
commit | 3f03d46fc13be2274b3c29d4fc97a3306bc33eda (patch) | |
tree | 4e54769273dc355dc482cf4ae28c220fd37ae61c | |
parent | 0e2721030857088803bc71ccc27644b7b95241ca (diff) | |
download | lvm2-3f03d46fc13be2274b3c29d4fc97a3306bc33eda.tar.gz |
man: dmeventd update
-rw-r--r-- | man/dmeventd.8.in | 92 |
1 files changed, 65 insertions, 27 deletions
diff --git a/man/dmeventd.8.in b/man/dmeventd.8.in index 77bbafb87..15e003ba3 100644 --- a/man/dmeventd.8.in +++ b/man/dmeventd.8.in @@ -1,7 +1,11 @@ .TH DMEVENTD 8 "DM TOOLS #VERSION#" "Red Hat Inc" \" -*- nroff -*- +. .SH NAME +. dmeventd \(em Device-mapper event daemon +. .SH SYNOPSIS +. .B dmeventd .RB [ \-d .RB [ \-d @@ -11,33 +15,53 @@ dmeventd \(em Device-mapper event daemon .RB [ \-R ] .RB [ \-V ] .RB [ \-? ] +. .SH DESCRIPTION +. dmeventd is the event monitoring daemon for device-mapper devices. Library plugins can register and carry out actions triggered when particular events occur. -.SH -LVM PLUGINS -.TP -.I Mirror -Attempts to handle device failure automatically. See \fBlvm.conf\fP(5). -.TP -.I Raid -Attempts to handle device failure automatically. See \fBlvm.conf\fP(5). -.TP -.I Snapshot +. +.SH LVM PLUGINS +. +.HP +.IR Mirror +.br +Attempts to handle device failure automatically. See +.BR lvm.conf (5). +. +.HP +.IR Raid +.br +Attempts to handle device failure automatically. See +.BR lvm.conf (5). +. +.HP +.IR Snapshot +.br Monitors how full a snapshot is becoming and emits a warning to syslog when it exceeds 80% full. The warning is repeated when 85%, 90% and 95% of the snapshot is filled. -See \fBlvm.conf\fP(5). -.TP -.I Thin -Monitors how full a thin pool is becoming and emits a warning to -syslog when it exceeds 80% full. +See +.BR lvm.conf (5). +Snapshot which runs out of space gets invalid and when it is mounted, +it gets umounted if possible. +. +.HP +.IR Thin +.br +Monitors how full a thin pool data and metadata is becoming and emits +a warning to syslog when it exceeds 80% full. The warning is repeated when 85%, 90% and 95% of the thin pool is filled. -See \fBlvm.conf\fP(5). +See +.BR lvm.conf (5). +If the thin-pool runs out of space, thin volumes are umounted if possible. +. .SH OPTIONS -.TP -.B \-d +. +.HP +.BR \-d +.br Repeat from 1 to 3 times ( .BR \-d , .BR \-dd , @@ -45,21 +69,35 @@ Repeat from 1 to 3 times ( ) to increase the detail of debug messages sent to syslog. Each extra d adds more debugging information. -.TP -.B \-f +. +.HP +.BR \-f +.br Don't fork, run in the foreground. -.TP -.BR \-h ", " \-? +. +.HP +.BR \-h +.br Show help information. -.TP -.B \-R +. +.HP +.BR \-? +.br +Show help information on stderr. +. +.HP +.BR \-R +.br Replace a running dmeventd instance. The running dmeventd must be version 2.02.77 or newer. The new dmeventd instance will obtain a list of devices and events to monitor from the currently running daemon. -.TP -.B \-V +. +.HP +.BR \-V +.br Show version of dmeventd. - +. .SH SEE ALSO +. .BR lvm (8), .BR lvm.conf (5) |