1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
|
#!/bin/sh
# Copyright (C) 2012-2013 Red Hat, Inc. All rights reserved.
#
# This copyrighted material is made available to anyone wishing to use,
# modify, copy, or redistribute it subject to the terms and conditions
# of the GNU General Public License v.2.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software Foundation,
# Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA
#
# test support of thin discards
#
SKIP_WITH_LVMPOLLD=1
export LVM_TEST_THIN_REPAIR_CMD=${LVM_TEST_THIN_REPAIR_CMD-/bin/false}
. lib/inittest
#
# Main
#
aux have_thin 1 1 0 || skip
aux prepare_pvs 2 64
aux extend_filter_LVMTEST
vgcreate $vg -s 64K $(cat DEVICES)
# Create named pool only
lvcreate -l1 --discards ignore -T $vg/pool
check lv_field $vg/pool discards "ignore"
check lv_field $vg/pool kernel_discards "ignore"
lvcreate -l1 --discards nopassdown -T $vg/pool1
check lv_field $vg/pool1 discards "nopassdown"
check lv_field $vg/pool1 kernel_discards "nopassdown"
lvcreate -l1 --discards passdown -T $vg/pool2
check lv_field $vg/pool2 discards "passdown"
check lv_field $vg/pool2 discards "passdown"
lvchange --discards nopassdown $vg/pool2
lvcreate -V1M -n origin -T $vg/pool
lvcreate -s $vg/origin -n snap
# Cannot convert active nopassdown -> ignore
not lvchange --discards nopassdown $vg/pool
# Cannot convert active ignore -> passdown
not lvchange --discards passdown $vg/pool
# Cannot convert active nopassdown -> ignore
not lvchange --discards ignore $vg/pool1
# Deactivate pool only
lvchange -an $vg/pool $vg/pool1
# Cannot convert, since thin volumes are still active
not lvchange --discards passdown $vg/pool
# Deactive thin volumes
lvchange -an $vg/origin $vg/snap
lvchange --discards passdown $vg/pool
check lv_field $vg/pool discards "passdown"
lvchange --discards ignore $vg/pool1
check lv_field $vg/pool1 discards "ignore"
vgremove -ff $vg
# Create thin pool with discards set to "ignore".
# If we create a thin volume which we use for a PV
# which we use to create another thin pool on top
# with discards set to "passdown", the discards value
# in metadata is still "passdown", but because the
# device below does not support it, the kernel value
# of discards actually used will be "nopassdown".
# This is why we have "-o discards" and "-o kernel_discards".
vgcreate -s 1m ${vg}_1 $(cat DEVICES)
lvcreate -l 10 -T ${vg}_1/pool --discards ignore
lvcreate -V 9m -T ${vg}_1/pool -n device_with_ignored_discards
vgcreate -s 1m ${vg}_2 "$DM_DEV_DIR/${vg}_1/device_with_ignored_discards"
lvcreate -l 1 -T ${vg}_2/pool --discards passdown
lvcreate -V 1 -T ${vg}_2/pool
check lv_field ${vg}_1/pool discards "ignore"
check lv_field ${vg}_1/pool kernel_discards "ignore"
check lv_field ${vg}_2/pool discards "passdown"
check lv_field ${vg}_2/pool kernel_discards "nopassdown"
vgremove -ff ${vg}_2
vgremove -ff ${vg}_1
|