diff options
author | msvensson@pilot.blaudden <> | 2007-05-24 11:21:27 +0200 |
---|---|---|
committer | msvensson@pilot.blaudden <> | 2007-05-24 11:21:27 +0200 |
commit | 93b1fe65d82661f29b1f6e1ad341eb0f68f4c93c (patch) | |
tree | b344506ca47d428ac52b3ed42e0688a171e767a0 /sql/net_serv.cc | |
parent | 9abaacca9cc7b44c66c0289f483cc13d9f5b64ab (diff) | |
download | mariadb-git-93b1fe65d82661f29b1f6e1ad341eb0f68f4c93c.tar.gz |
Bug#26664 test suite times out on OS X 64bit
- The "mysql client in mysqld"(which is used by
replication and federated) should use alarms instead of setting
socket timeout value if the rest of the server uses alarm. By
always calling 'my_net_set_write_timeout'
or 'my_net_set_read_timeout' when changing the timeout value(s), the
selection whether to use alarms or timeouts will be handled by
ifdef's in those two functions.
- Move declaration of 'vio_timeout' into "vio_priv.h"
Diffstat (limited to 'sql/net_serv.cc')
-rw-r--r-- | sql/net_serv.cc | 16 |
1 files changed, 8 insertions, 8 deletions
diff --git a/sql/net_serv.cc b/sql/net_serv.cc index ef929bc67f0..4b79e411a53 100644 --- a/sql/net_serv.cc +++ b/sql/net_serv.cc @@ -609,10 +609,10 @@ net_real_write(NET *net,const char *packet,ulong len) #ifndef NO_ALARM thr_alarm_init(&alarmed); if (net_blocking) - thr_alarm(&alarmed,(uint) net->write_timeout,&alarm_buff); + thr_alarm(&alarmed, net->write_timeout, &alarm_buff); #else alarmed=0; - /* Write timeout is set in net_set_write_timeout */ + /* Write timeout is set in my_net_set_write_timeout */ #endif /* NO_ALARM */ pos=(char*) packet; end=pos+len; @@ -624,7 +624,7 @@ net_real_write(NET *net,const char *packet,ulong len) #if (!defined(__WIN__) && !defined(__EMX__) && !defined(OS2)) if ((interrupted || length==0) && !thr_alarm_in_use(&alarmed)) { - if (!thr_alarm(&alarmed,(uint) net->write_timeout,&alarm_buff)) + if (!thr_alarm(&alarmed, net->write_timeout, &alarm_buff)) { /* Always true for client */ my_bool old_mode; while (vio_blocking(net->vio, TRUE, &old_mode) < 0) @@ -805,7 +805,7 @@ my_real_read(NET *net, ulong *complen) if (net_blocking) thr_alarm(&alarmed,net->read_timeout,&alarm_buff); #else - /* Read timeout is set in net_set_read_timeout */ + /* Read timeout is set in my_net_set_read_timeout */ #endif /* NO_ALARM */ pos = net->buff + net->where_b; /* net->packet -4 */ @@ -1117,9 +1117,9 @@ my_net_read(NET *net) } -void net_set_read_timeout(NET *net, uint timeout) +void my_net_set_read_timeout(NET *net, uint timeout) { - DBUG_ENTER("net_set_read_timeout"); + DBUG_ENTER("my_net_set_read_timeout"); DBUG_PRINT("enter", ("timeout: %d", timeout)); net->read_timeout= timeout; #ifdef NO_ALARM @@ -1129,9 +1129,9 @@ void net_set_read_timeout(NET *net, uint timeout) } -void net_set_write_timeout(NET *net, uint timeout) +void my_net_set_write_timeout(NET *net, uint timeout) { - DBUG_ENTER("net_set_write_timeout"); + DBUG_ENTER("my_net_set_write_timeout"); DBUG_PRINT("enter", ("timeout: %d", timeout)); net->write_timeout= timeout; #ifdef NO_ALARM |