--source include/have_innodb.inc --source alter_sql_mode.inc let $sql_mode = `SELECT @@SQL_MODE`; let $error_code = 0; if ($sql_mode == "STRICT_TRANS_TABLES") { let $error_code = WARN_DATA_TRUNCATED; } CREATE TABLE t1(f1 INT)ENGINE=INNODB; INSERT INTO t1 VALUES(NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE f1 f1 INT NOT NULL; --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(f1 CHAR(10))ENGINE=INNODB; INSERT INTO t1 VALUES(NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE f1 f1 CHAR(10) NOT NULL; --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(f1 VARCHAR(10))ENGINE=INNODB; INSERT INTO t1 VALUES(NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE f1 f1 VARCHAR(20) NOT NULL; --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(f1 TEXT)ENGINE=INNODB; INSERT INTO t1 VALUES(NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE f1 f1 TEXT NOT NULL DEFAULT 'abc'; --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(f1 INT NOT NULL, f2 INT NOT NULL, f3 INT)ENGINE=INNODB; INSERT INTO t1 VALUES(2, 2, NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE f3 f3 INT NOT NULL DEFAULT (f1 + f2); --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(f1 INT NOT NULL DEFAULT 0, b TINYINT)ENGINE=InnoDB; INSERT INTO t1 VALUES(10, NULL); SELECT * FROM t1; --enable_info --error $error_code ALTER TABLE t1 CHANGE b b TINYINT NOT NULL DEFAULT if(unix_timestamp()>1,1000,0); --disable_info SELECT * FROM t1; DROP TABLE t1; CREATE TABLE t1(a INT, v INT AS (a), c INT, d INT NOT NULL, e INT) ENGINE=InnoDB; --enable_info ALTER TABLE t1 DROP COLUMN c, CHANGE COLUMN e e INT NOT NULL; --disable_info DROP TABLE t1; CREATE TABLE t1 (a INT, v INT AS (a), d INT NOT NULL, e INT) ENGINE=InnoDB; --enable_info ALTER TABLE t1 FORCE; --disable_info DROP TABLE t1; # Alter ignore should work irrespective of sql mode CREATE TABLE t1(c1 INT NOT NULL, c2 INT, PRIMARY KEY(c1))ENGINE=INNODB; INSERT INTO t1 VALUES(1, NULL); --enable_info ALTER IGNORE TABLE t1 CHANGE c2 c2 INT NOT NULL DEFAULT 2; --disable_info SELECT * FROM t1; DROP TABLE t1; --echo # --echo # MDEV-16126 Crash or ASAN heap-buffer-overflow in --echo # mach_read_from_n_little_endian upon ALTER TABLE with blob --echo # CREATE TABLE t1(a INT, v INT AS (a), b INT, c BLOB) ENGINE=InnoDB; --enable_info ALTER TABLE t1 ADD PRIMARY KEY(b); --disable_info DROP TABLE t1;