/** * Tests that flow control outputs a log when it is maximally engaged on some cadence. * * @tags: [ * requires_flow_control, * requires_majority_read_concern, * requires_replication, * ] */ (function() { "use strict"; const replSet = new ReplSetTest({name: "flow_control_logging", nodes: 3}); replSet.startSet({ setParameter: { flowControlSamplePeriod: 1, // Increase resolution to detect lag in a light write workload. flowControlWarnThresholdSeconds: 1, // Configure flow control to engage after one second of lag. flowControlTargetLagSeconds: 1, flowControlThresholdLagPercentage: 1, // Use a speedy no-op writer to avoid needing a robust background writer. writePeriodicNoops: true, periodicNoopIntervalSecs: 2 // replSet.initiate() can hang with a one second interval for reasons. } }); replSet.initiate(); // Stop replication which will pin the commit point. for (let sec of replSet.getSecondaries()) { assert.commandWorked(sec.adminCommand( {configureFailPoint: "pauseBatchApplicationAfterWritingOplogEntries", mode: "alwaysOn"})); } const timeoutMilliseconds = 30 * 1000; // The test has stopped replication and the primary's no-op writer is configured to create an // oplog entry every other second. Once the primary notices the sustainer rate is not moving, it // should start logging a warning once per second. This check waits for two log messages to make // sure the appropriate state variables are being reset. checkLog.containsWithAtLeastCount(replSet.getPrimary(), "Flow control is engaged and the sustainer point is not moving.", 2, timeoutMilliseconds); // Restart replication so the replica set will shut down. for (let sec of replSet.getSecondaries()) { assert.commandWorked(sec.adminCommand( {configureFailPoint: "pauseBatchApplicationAfterWritingOplogEntries", mode: "off"})); } replSet.stopSet(); })();