summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorJenkins <jenkins@review.openstack.org>2017-08-17 12:20:27 +0000
committerGerrit Code Review <review@openstack.org>2017-08-17 12:20:27 +0000
commit9d914c85939bcbdd64c28ba9899b730c01d74df1 (patch)
tree67ba66d5ee219f7cfadbc48c1caefb52848364da
parent8c5d783ffe3ae71175539c27c70809e5f139e312 (diff)
parent888610f43ac328de9850b3edae96e83b42c7611f (diff)
downloadironic-9d914c85939bcbdd64c28ba9899b730c01d74df1.tar.gz
Merge "[releasenotes] update irmc's boot-from-volume support"9.0.0
-rw-r--r--releasenotes/notes/irmc-boot-from-volume-4bc5d20a0a780669.yaml36
1 files changed, 3 insertions, 33 deletions
diff --git a/releasenotes/notes/irmc-boot-from-volume-4bc5d20a0a780669.yaml b/releasenotes/notes/irmc-boot-from-volume-4bc5d20a0a780669.yaml
index 9f8b1ef0d..6554f1546 100644
--- a/releasenotes/notes/irmc-boot-from-volume-4bc5d20a0a780669.yaml
+++ b/releasenotes/notes/irmc-boot-from-volume-4bc5d20a0a780669.yaml
@@ -1,37 +1,7 @@
---
features:
- |
- Adds support for booting from remote volumes to ``irmc-virtual-media``
+ Adds support for booting from remote volumes via the ``irmc-virtual-media``
boot interface. It enables boot configuration for iSCSI or FibreChannel
- via out-of-band network.
-
- In addition to the same configuration as generic boot-from-volume, this
- interface requires the following settings.
-
- * It is necessary to set a physical port ID to network ports and volume
- connectors. All cards including those not used for volume boot should be
- registered.
-
- * A physical ID format is: ``<Card Type><Slot No>-<Port No>``
-
- ``<Card Type>``
- LAN, FC or CNA
- ``<Slot No>``
- 0 indicates onboard slot. Use 1 to 9 for addon slots.
- ``<Port No>``
- A port number starting from 1.
-
- * Set the IDs to ``node.driver_info.pci_physical_ids``. This parameter
- is a list of pair of UUID of a resource (Port or Volume connector)
- and a physical ID like:
-
- pci_physical_ids = 1ecd14ee-c191-4007-8413-16bb5d5a73a2:LAN0-1,1ecd14ee-c191-4007-8413-16bb5d5a73a2:CNA1-1
-
- * For iSCSI, volume connectors with both type ``iqn`` and ``ip`` are
- required. The configuration with DHCP is not supported yet.
-
- * For iSCSI, a subnet mask of the storage network is necessary. It should
- be set to ``node.driver_info.storage_network_size`` as integer.
-
- This feature requires specific FC cards or CNAs (Converged Network Adapter).
- See the documentation of iRMC driver for details.
+ via out-of-band network. For details, see the `iRMC driver documentation
+ <https://docs.openstack.org/ironic/latest/admin/drivers/irmc.html#boot-from-remote-volume>`_.