Merge "DRAC: Fix a failure to create virtual disk"
Diffstat (limited to 'releasenotes')
-rw-r--r-- | releasenotes/notes/idrac-add-ehba-support-10b90c92b8865364.yaml | 15 |
1 files changed, 15 insertions, 0 deletions
diff --git a/releasenotes/notes/idrac-add-ehba-support-10b90c92b8865364.yaml b/releasenotes/notes/idrac-add-ehba-support-10b90c92b8865364.yaml new file mode 100644 index 000000000..baf41b3e1 --- /dev/null +++ b/releasenotes/notes/idrac-add-ehba-support-10b90c92b8865364.yaml @@ -0,0 +1,15 @@ +fixes: + - | + Fixes the virtual disks creation by changing PERC H740P controller + mode from `Enhanced HBA` to `RAID` in delete_configuration clean + step. + PERC H740P controllers supports RAID mode and Enhanced HBA mode. + When the controller is in Enhanced HBA, it creates single disk + RAID0 virtual disks of NON-RAID physical disks. + Hence the request for VD creation with supported RAID + fails due to no available physical disk. + This patch converts the PERC H740P RAID controllers to RAID mode + if enhanced HBA mode found enabled + See bug + `bug 2007711 <https://storyboard.openstack.org/#!/story/2007711>`_ + for more details |