From eb5df105684e31a54c5dd3914d91ef148d66ee7e Mon Sep 17 00:00:00 2001 From: Ben Pfaff Date: Thu, 20 Sep 2018 16:44:11 -0700 Subject: ovn: Fix indentation in TODO. Some items listed under ovsdb-server should have been top-level items. Signed-off-by: Ben Pfaff --- ovn/TODO.rst | 42 +++++++++++++++++++++--------------------- 1 file changed, 21 insertions(+), 21 deletions(-) (limited to 'ovn') diff --git a/ovn/TODO.rst b/ovn/TODO.rst index 101a127d8..33489174f 100644 --- a/ovn/TODO.rst +++ b/ovn/TODO.rst @@ -111,34 +111,34 @@ OVN To-do List Without Prior Context". (I'm not yet aware of previous non-academic use of this technique.) - * Support multiple tunnel encapsulations in Chassis. +* Support multiple tunnel encapsulations in Chassis. - So far, both ovn-controller and ovn-controller-vtep only allow chassis to - have one tunnel encapsulation entry. We should extend the implementation - to support multiple tunnel encapsulations. + So far, both ovn-controller and ovn-controller-vtep only allow chassis to + have one tunnel encapsulation entry. We should extend the implementation + to support multiple tunnel encapsulations. - * Update learned MAC addresses from VTEP to OVN +* Update learned MAC addresses from VTEP to OVN - The VTEP gateway stores all MAC addresses learned from its physical - interfaces in the 'Ucast_Macs_Local' and the 'Mcast_Macs_Local' tables. - ovn-controller-vtep should be able to update that information back to - ovn-sb database, so that other chassis know where to send packets destined - to the extended external network instead of broadcasting. + The VTEP gateway stores all MAC addresses learned from its physical + interfaces in the 'Ucast_Macs_Local' and the 'Mcast_Macs_Local' tables. + ovn-controller-vtep should be able to update that information back to + ovn-sb database, so that other chassis know where to send packets destined + to the extended external network instead of broadcasting. - * Translate ovn-sb Multicast_Group table into VTEP config +* Translate ovn-sb Multicast_Group table into VTEP config - The ovn-controller-vtep daemon should be able to translate the - Multicast_Group table entry in ovn-sb database into Mcast_Macs_Remote table - configuration in VTEP database. + The ovn-controller-vtep daemon should be able to translate the + Multicast_Group table entry in ovn-sb database into Mcast_Macs_Remote table + configuration in VTEP database. - * OVN OCF pacemaker script to support Active / Passive HA for OVN dbs provides - the option to configure the inactivity_probe value. The default 5 seconds - inactivity_probe value is not sufficient and ovsdb-server drops the client - IDL connections for openstack deployments when the neutron server is heavily - loaded. +* OVN OCF pacemaker script to support Active / Passive HA for OVN dbs provides + the option to configure the inactivity_probe value. The default 5 seconds + inactivity_probe value is not sufficient and ovsdb-server drops the client + IDL connections for openstack deployments when the neutron server is heavily + loaded. - We need to find a proper solution to solve this issue instead of increasing - the inactivity_probe value. + We need to find a proper solution to solve this issue instead of increasing + the inactivity_probe value. * ACL -- cgit v1.2.1