diff options
Diffstat (limited to 'src/components/policy/policy_external/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt')
-rw-r--r-- | src/components/policy/policy_external/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt | 131 |
1 files changed, 131 insertions, 0 deletions
diff --git a/src/components/policy/policy_external/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt b/src/components/policy/policy_external/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt new file mode 100644 index 0000000000..f11faadfdc --- /dev/null +++ b/src/components/policy/policy_external/doc/doxygen/components/TransportManager/Use Cases/UseCase3.txt @@ -0,0 +1,131 @@ +/*! \page components_transportmanager_use_cases_3 Scenario with 2 or more devices with 2 or more applications onboard + +<h3>Preconditions:</h3> +<table> + <tr> + <th>Steps</th> + <th>Actions</th> + <th>Expected result</th> + </tr> + <tr> + <td>1</td> + <td>Device-1 is connected to Core via Bluetooth</td> + <td>Devices are paired</td> + </tr> + <tr> + <td>2</td> + <td>Device-2 is connected to SmartDeviceLink Core via Wi-Fi</td> + <td>Devices are in the same network</td> + </tr> + <tr> + <td>3</td> + <td>Make sure that correct devices are connected to SmartDeviceLink core</td> + <td>IP-address of connected devices are relevant</td> + </tr> +</table> + +<h3>Testcase:</h3> +<table> + <tr> + <th>Steps</th> + <th>Actions</th> + <th>Expected result</th> + </tr> + <tr> + <td>1</td> + <td>Start SmartDeviceLink application on the Devices</td> + <td>SmartDeviceLink application is up and ready</td> + </tr> + <tr> + <td>2</td> + <td>Initiate a Device search in HMI</td> + <td>HMI displays the list of found devices/applications</td> + </tr> + <tr> + <td>3</td> + <td>Connect to application-1 on 1-st device</td> + <td>Application is marked as connected/notification is displayed in HMI</td> + </tr> + <tr> + <td>4</td> + <td>Send alert message from SmartDeviceLink application-1 on device-1</td> + <td>Alert is displayed on HMI</td> + </tr> + <tr> + <td>5</td> + <td>Connect to application-2 on 1-st device</td> + <td>Application is marked as connected/notification is displayed in HMI Both applications are marked as connected</td> + </tr> + <tr> + <td>6</td> + <td>Send alert message from SmartDeviceLink application-2 on device-1</td> + <td>Alert is displayed on HMI</td> + </tr> + <tr> + <td>7</td> + <td>Send alert messages from application-1 and application-2 on device-1 simultaneously</td> + <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> + </tr> + <tr> + <td>8</td> + <td>Connect to application-1 on 2-st device</td> + <td>Application is marked as connected/notification is displayed in HMI. All 3 applications are marked as connected</td> + </tr> + <tr> + <td>9</td> + <td>Send alert messages from application-1 on device-1 and device-2 simultaneously</td> + <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> + </tr> + <tr> + <td>10</td> + <td>Send alert message from SmartDeviceLink application-1 on device-2</td> + <td>Alert is displayed on HMI</td> + </tr> + <tr> + <td>11</td> + <td>Connect to application on 2-nd device</td> + <td>Application is marked as connected/notification is displayed in HMI. All 4 applications are marked as connected</td> + </tr> + <tr> + <td>12</td> + <td>Send alert message from SmartDeviceLink application-2 on device-2</td> + <td>Alert is displayed on HMI</td> + </tr> + <tr> + <td>13</td> + <td>Send alert messages from application-1 and application-2 on device-2 simultaneously</td> + <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> + </tr> + <tr> + <td>14</td> + <td>Send alert messages from application-2 on device-1 and device-2 simultaneously</td> + <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> + </tr> + <tr> + <td>15</td> + <td>Send alert messages from all application simultaneously</td> + <td>Both alerts are displayed on HMI/Alerts are showed consequently</td> + </tr> + <tr> + <td>16</td> + <td>Disconnect device-1 from SmartDeviceLink core</td> + <td>Applications are marked as disconnected/notification is displayed in HMI</td> + </tr> + <tr> + <td>17</td> + <td>Disconnect device-2 from SmartDeviceLink core</td> + <td>All applications are marked as disconnected/notification is displayed in HMI</td> + </tr> + <tr> + <td>18</td> + <td><strong>Repeat steps 1-15 with more devices and more applications or use same connection method (BT of Wi-Fi)</strong></td> + <td>Expected results should be the same</td> + </tr> + <tr> + <td>19</td> + <td><h3>Stress:</h3>Send big amount of alert messages in a short period of time from all devices</td> + <td>All alert messages are processed correctly</td> + </tr> +</table> + +*/ |