%entities; ]> systemd-system.conf systemd systemd-system.conf 5 systemd-system.conf system.conf.d systemd-user.conf user.conf.d System and session service manager configuration files /etc/systemd/system.conf, /etc/systemd/system.conf.d/*.conf, /run/systemd/system.conf.d/*.conf, /usr/lib/systemd/system.conf.d/*.conf /etc/systemd/user.conf, /etc/systemd/user.conf.d/*.conf, /run/systemd/user.conf.d/*.conf, /usr/lib/systemd/user.conf.d/*.conf Description When run as a system instance, systemd interprets the configuration file system.conf and the files in system.conf.d directories; when run as a user instance, systemd interprets the configuration file user.conf and the files in user.conf.d directories. These configuration files contain a few settings controlling basic manager operations. See systemd.syntax5 for a general description of the syntax. Options All options are configured in the [Manager] section: LogLevel= LogTarget= LogColor= LogLocation= DumpCore=yes CrashChangeVT=no CrashShell=no CrashReboot=no ShowStatus=yes DefaultStandardOutput=journal DefaultStandardError=inherit Configures various parameters of basic manager operation. These options may be overridden by the respective process and kernel command line arguments. See systemd1 for details. CtrlAltDelBurstAction= Defines what action will be performed if user presses Ctrl-Alt-Delete more than 7 times in 2s. Can be set to reboot-force, poweroff-force, reboot-immediate, poweroff-immediate or disabled with none. Defaults to reboot-force. CPUAffinity= Configures the CPU affinity for the service manager as well as the default CPU affinity for all forked off processes. Takes a list of CPU indices or ranges separated by either whitespace or commas. CPU ranges are specified by the lower and upper CPU indices separated by a dash. This option may be specified more than once, in which case the specified CPU affinity masks are merged. If the empty string is assigned, the mask is reset, all assignments prior to this will have no effect. Individual services may override the CPU affinity for their processes with the CPUAffinity= setting in unit files, see systemd.exec5. JoinControllers=cpu,cpuacct net_cls,netprio Configures controllers that shall be mounted in a single hierarchy. By default, systemd will mount all controllers which are enabled in the kernel in individual hierarchies, with the exception of those listed in this setting. Takes a space-separated list of comma-separated controller names, in order to allow multiple joined hierarchies. Defaults to 'cpu,cpuacct'. Pass an empty string to ensure that systemd mounts all controllers in separate hierarchies. Note that this option is only applied once, at very early boot. If you use an initial RAM disk (initrd) that uses systemd, it might hence be necessary to rebuild the initrd if this option is changed, and make sure the new configuration file is included in it. Otherwise, the initrd might mount the controller hierarchies in a different configuration than intended, and the main system cannot remount them anymore. NUMAPolicy= Configures the NUMA memory policy for the service manager and the default NUMA memory policy for all forked off processes. Individual services may override the default policy with the NUMAPolicy= setting in unit files, see systemd.exec5. NUMAMask= Configures the NUMA node mask that will be associated with the selected NUMA policy. Note that and NUMA policies don't require explicit NUMA node mask and value of the option can be empty. Similarly to NUMAPolicy=, value can be overriden by individual services in unit files, see systemd.exec5. RuntimeWatchdogSec= ShutdownWatchdogSec= Configure the hardware watchdog at runtime and at reboot. Takes a timeout value in seconds (or in other time units if suffixed with ms, min, h, d, w). If RuntimeWatchdogSec= is set to a non-zero value, the watchdog hardware (/dev/watchdog or the path specified with WatchdogDevice= or the kernel option systemd.watchdog-device=) will be programmed to automatically reboot the system if it is not contacted within the specified timeout interval. The system manager will ensure to contact it at least once in half the specified timeout interval. This feature requires a hardware watchdog device to be present, as it is commonly the case in embedded and server systems. Not all hardware watchdogs allow configuration of all possible reboot timeout values, in which case the closest available timeout is picked. ShutdownWatchdogSec= may be used to configure the hardware watchdog when the system is asked to reboot. It works as a safety net to ensure that the reboot takes place even if a clean reboot attempt times out. Note that the ShutdownWatchdogSec= timeout applies only to the second phase of the reboot, i.e. after all regular services are already terminated, and after the system and service manager process (PID 1) got replaced by the systemd-shutdown binary, see system bootup7 for details. During the first phase of the shutdown operation the system and service manager remains running and hence RuntimeWatchdogSec= is still honoured. In order to define a timeout on this first phase of system shutdown, configure JobTimeoutSec= and JobTimeoutAction= in the [Unit] section of the shutdown.target unit. By default RuntimeWatchdogSec= defaults to 0 (off), and ShutdownWatchdogSec= to 10min. These settings have no effect if a hardware watchdog is not available. WatchdogDevice= Configure the hardware watchdog device that the runtime and shutdown watchdog timers will open and use. Defaults to /dev/watchdog. This setting has no effect if a hardware watchdog is not available. CapabilityBoundingSet= Controls which capabilities to include in the capability bounding set for PID 1 and its children. See capabilities7 for details. Takes a whitespace-separated list of capability names as read by cap_from_name3. Capabilities listed will be included in the bounding set, all others are removed. If the list of capabilities is prefixed with ~, all but the listed capabilities will be included, the effect of the assignment inverted. Note that this option also affects the respective capabilities in the effective, permitted and inheritable capability sets. The capability bounding set may also be individually configured for units using the CapabilityBoundingSet= directive for units, but note that capabilities dropped for PID 1 cannot be regained in individual units, they are lost for good. NoNewPrivileges= Takes a boolean argument. If true, ensures that PID 1 and all its children can never gain new privileges through execve2 (e.g. via setuid or setgid bits, or filesystem capabilities). Defaults to false. General purpose distributions commonly rely on executables with setuid or setgid bits and will thus not function properly with this option enabled. Individual units cannot disable this option. Also see No New Privileges Flag. SystemCallArchitectures= Takes a space-separated list of architecture identifiers. Selects from which architectures system calls may be invoked on this system. This may be used as an effective way to disable invocation of non-native binaries system-wide, for example to prohibit execution of 32-bit x86 binaries on 64-bit x86-64 systems. This option operates system-wide, and acts similar to the SystemCallArchitectures= setting of unit files, see systemd.exec5 for details. This setting defaults to the empty list, in which case no filtering of system calls based on architecture is applied. Known architecture identifiers are x86, x86-64, x32, arm and the special identifier native. The latter implicitly maps to the native architecture of the system (or more specifically, the architecture the system manager was compiled for). Set this setting to native to prohibit execution of any non-native binaries. When a binary executes a system call of an architecture that is not listed in this setting, it will be immediately terminated with the SIGSYS signal. TimerSlackNSec= Sets the timer slack in nanoseconds for PID 1, which is inherited by all executed processes, unless overridden individually, for example with the TimerSlackNSec= setting in service units (for details see systemd.exec5). The timer slack controls the accuracy of wake-ups triggered by system timers. See prctl2 for more information. Note that in contrast to most other time span definitions this parameter takes an integer value in nano-seconds if no unit is specified. The usual time units are understood too. DefaultTimerAccuracySec= Sets the default accuracy of timer units. This controls the global default for the AccuracySec= setting of timer units, see systemd.timer5 for details. AccuracySec= set in individual units override the global default for the specific unit. Defaults to 1min. Note that the accuracy of timer units is also affected by the configured timer slack for PID 1, see TimerSlackNSec= above. DefaultTimeoutStartSec= DefaultTimeoutStopSec= DefaultRestartSec= Configures the default timeouts for starting and stopping of units, as well as the default time to sleep between automatic restarts of units, as configured per-unit in TimeoutStartSec=, TimeoutStopSec= and RestartSec= (for services, see systemd.service5 for details on the per-unit settings). For non-service units, DefaultTimeoutStartSec= sets the default TimeoutSec= value. DefaultTimeoutStartSec= and DefaultTimeoutStopSec= default to 90s. DefaultRestartSec= defaults to 100ms. DefaultStartLimitIntervalSec= DefaultStartLimitBurst= Configure the default unit start rate limiting, as configured per-service by StartLimitIntervalSec= and StartLimitBurst=. See systemd.service5 for details on the per-service settings. DefaultStartLimitIntervalSec= defaults to 10s. DefaultStartLimitBurst= defaults to 5. DefaultEnvironment= Sets manager environment variables passed to all executed processes. Takes a space-separated list of variable assignments. See environ7 for details about environment variables. Example: DefaultEnvironment="VAR1=word1 word2" VAR2=word3 "VAR3=word 5 6" Sets three variables VAR1, VAR2, VAR3. DefaultCPUAccounting= DefaultBlockIOAccounting= DefaultMemoryAccounting= DefaultTasksAccounting= DefaultIPAccounting= Configure the default resource accounting settings, as configured per-unit by CPUAccounting=, BlockIOAccounting=, MemoryAccounting=, TasksAccounting= and IPAccounting=. See systemd.resource-control5 for details on the per-unit settings. DefaultTasksAccounting= defaults to on, DefaultMemoryAccounting= to &MEMORY_ACCOUNTING_DEFAULT;, the other three settings to off. DefaultTasksMax= Configure the default value for the per-unit TasksMax= setting. See systemd.resource-control5 for details. This setting applies to all unit types that support resource control settings, with the exception of slice units. Defaults to 80%, which equals 26214 with the kernel's defaults on the host, but might be smaller in OS containers. DefaultLimitCPU= DefaultLimitFSIZE= DefaultLimitDATA= DefaultLimitSTACK= DefaultLimitCORE= DefaultLimitRSS= DefaultLimitNOFILE= DefaultLimitAS= DefaultLimitNPROC= DefaultLimitMEMLOCK= DefaultLimitLOCKS= DefaultLimitSIGPENDING= DefaultLimitMSGQUEUE= DefaultLimitNICE= DefaultLimitRTPRIO= DefaultLimitRTTIME= These settings control various default resource limits for units. See setrlimit2 for details. The resource limit is possible to specify in two formats, to set soft and hard limits to the same value, or to set both limits individually (e.g. DefaultLimitAS=4G:16G). Use the string infinity to configure no limit on a specific resource. The multiplicative suffixes K (=1024), M (=1024*1024) and so on for G, T, P and E may be used for resource limits measured in bytes (e.g. DefaultLimitAS=16G). For the limits referring to time values, the usual time units ms, s, min, h and so on may be used (see systemd.time7 for details). Note that if no time unit is specified for DefaultLimitCPU= the default unit of seconds is implied, while for DefaultLimitRTTIME= the default unit of microseconds is implied. Also, note that the effective granularity of the limits might influence their enforcement. For example, time limits specified for DefaultLimitCPU= will be rounded up implicitly to multiples of 1s. These settings may be overridden in individual units using the corresponding LimitXXX= directives. Note that these resource limits are only defaults for units, they are not applied to PID 1 itself. See Also systemd1, systemd.directives7, systemd.exec5, systemd.service5, environ7, capabilities7