it83xx: Enable USB module's clock before set USB control register
symptom:
On bip, the PPC's INT pin is always asserted after we do a EC reboot
command.
This is because the setting of clock gating control register will
not be reset with a EC reboot command.
Clock gating control register only resets by EC's WRST# pin
BUG=b:111006203, b:110237505
BRANCH=none
TEST=The PPC's INT pin is deasserted after EC reboot command.