-/* Copyright 2016 The Chromium OS Authors. All rights reserved.
- * Use of this source code is governed by a BSD-style license that can be
- * found in the LICENSE file.
- */
-#ifndef BIOD_BIO_ALGORITHM_H_
-#define BIOD_BIO_ALGORITHM_H_
-
-#include <stdint.h>
-
-enum bio_algorithm_type {
- BIO_ALGORITHM_FINGERPRINT,
- BIO_ALGORITHM_IRIS,
-};
-/*
- * An opaque pointer representing/uniquely identifying a sensor.
- */
-typedef void *bio_sensor_t;
-/*
- * An opaque pointer representing an image (scan).
- */
-typedef void *bio_image_t;
-/*
- * An opaque pointer representing/uniquely identifying an (serialized) enrolled
- * template.
- */
-typedef void *bio_template_t;
-/*
- * An opaque pointer representing/uniquely identifying enrollment attempt.
- */
-typedef void *bio_enrollment_t;
-/*
- * Initializes biometric algorithm library. Should be the very first function
- * to be invoked by the biometric daemon.
- *
- * Returns 0 on success, negative error code (such as -ENOMEM) on failure.
- */
-int bio_algorithm_init(void);
-/*
- * Instructs the biometric library to release all resources in preparation
- * for the process termination (or unloading the library). Regardless of
- * the returned error code the action is considered unrecoverable.
- *
- * Returns 0 on success, negative error code (such as -ENOMEM) on failure.
- */
-int bio_algorithm_exit(void);
-/*
- * Used to retrieve type of the algorithm library. Might be used by
- * configuration processor module to match sensors and algorithm libraries.
- */
-enum bio_algorithm_type bio_algorithm_get_type(void);
-/*
- * Used to retrieve name of the algorithm library, to be used in diagnostics.
- * Also might be used by configuration processor module to match sensors and
- * algorithm libraries.
- */
-const char *bio_algorithm_get_name(void);
-/*
- * Used to retrieve version of the algorithm library, to be used in diagnostics.
- */
-const char *bio_algorithm_get_version(void);
-/*
- * Used to retrieve additional information from the algorithm library, to be
- * used in diagnostics.
- */
-const char *bio_algorithm_get_banner(void);
-/*
- * Initializes a new sensor structure and returns its handle that will be used
- * in other calls to identify the sensor involved in the operation.
- *
- * Returns 0 on success, negative error code (such as -ENOMEM) on failure.
- */
-int bio_sensor_create(bio_sensor_t *sensor);
-/*
- * Releases all resources held by the library in conjunction with given sensor.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_sensor_destroy(bio_sensor_t sensor);
-/*
- * Communicates particulars of a given sensor so that algorithm library can
- * adjust its behavior as needed.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_sensor_set_model(bio_sensor_t sensor, uint32_t vendor_id,
- uint32_t product_id, uint32_t model_id,
- uint32_t version);
-/*
- * Communicates format of data used by given sensor to the algorithm library.
- * This is a fourcc value defined by V4L2 API.
- * Could be a new define for biometric sensors or V4L2_PIX_FMT_GREY.
- * Algorithm library will return error if it can not work with given format.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_sensor_set_format(bio_sensor_t sensor, uint32_t pixel_format);
-/*
- * Communicates dimensions of given sensor to the algorithm library.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_sensor_set_size(bio_sensor_t sensor, uint32_t width, uint32_t height);
-/*
- * Instructs the algorithm library to initialize a new structure to hold
- * biometric image of given dimensions acquired from given sensor.
- * It will return image handle that will be used in other calls to identify
- * the image involved in the operation.
- *
- * Returns 0 on success, negative error code (such as -ENOMEM) on failure.
- */
-int bio_image_create(bio_sensor_t sensor, uint32_t width, uint32_t height,
- bio_image_t *image);
-/*
- * Communicates dimensions of image to the algorithm library.
- * Can be used if image is less than full sensor resolution.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_image_set_size(bio_image_t image, uint32_t width, uint32_t height);
-/*
- * Attaches data from biometric sensor to image structure. The caller must
- * ensure that there is enough of data for given image dimensions for given
- * format used by the sensor.
- *
- * It is assumes that the data pointer stays valid until bio_image_destroy()
- * is called.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_image_set_data(bio_image_t image, const uint8_t *data, size_t size);
-/*
- * Releases all resources held by the library in conjunction with given image.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_image_destroy(bio_image_t image);
-
-/*
- * Compares given biometric image against a list of enrolled template(s).
- * In case the image match a template the match_index will indicate which
- * template in the list that matched.
- * The algorithm library can update templates with additional biometric data
- * from the image, if it chooses to do so. The updated template(s) will be
- * indicated by the out parameter 'updated_templates', a bit-field where
- * updated template(s) indicated by the corresponding bit being set
- * Returns:
- * - negative value on error
- * - BIO_TEMPLATE_NO_MATCH on non-match
- * - BIO_TEMPLATE_MATCH for match when template was not updated with new data
- * - BIO_TEMPLATE_MATCH_UPDATED for match when template was updated
- * - BIO_TEMPLATE_MATCH_UPDATE_FAILED match, but update failed (do not save)
- * - BIO_TEMPLATE_LOW_QUALITY when matching could not be performed due to low
- * image quality
- * - BIO_TEMPLATE_LOW_COVERAGE when matching could not be performed due to
- * finger covering too little area of the sensor
- */
-int bio_template_image_match_list(bio_template_t tmpl, uint32_t num_templates,
- bio_image_t image, int32_t *match_index,
- uint32_t *updated_templates);
-int bio_template_image_match(bio_template_t tmpl, bio_image_t image);
-/*
- * Returns size of template data in serialized form.
- *
- * Returns negative error code (such as -EINVAL) on failure, or size of the
- * serialized form in bytes.
- */
-ssize_t bio_template_get_serialized_size(bio_template_t tmpl);
-/*
- * Releases all resources held by the library in conjunction with given
- * template.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_template_destroy(bio_template_t tmpl);
-/*
- * Initiates biometric data enrollment process. Algorithm library returns
- * 'enrollment handle' that is used for all subsequent enrollment operations.
- *
- * Returns 0 on success, negative error code (such as -ENOMEM) on failure.
- */
-int bio_enrollment_begin(bio_sensor_t sensor, bio_enrollment_t *enrollment);
-/*
- * Adds fingerprint image to an enrollment.
- *
- * The library should expect to copy any relevant data from the “image”
- * as it is likely to be destroyed (via bio_image_destroy() call) shortly after
- * this call completes.
- *
- * Returns:
- * - negative value on error
- * - BIO_ENROLLMENT_OK when image was successfully enrolled
- * - BIO_ENROLLMENT_IMMOBILE when image added, but user should be advised
- * to move finger
- * - BIO_ENROLLMENT_LOW_QUALITY when image could not be used due to low
- * image quality
- * - BIO_ENROLLMENT_LOW_COVERAGE when image could not be used due to
- * finger covering too little area of the sensor
- */
-#define BIO_ENROLLMENT_OK 0
-#define BIO_ENROLLMENT_IMMOBILE 2
-#define BIO_ENROLLMENT_LOW_QUALITY 1
-#define BIO_ENROLLMENT_LOW_COVERAGE 3
-/* Can be used to detect if image was usable for enrollment or not. */
-#define BIO_ENROLLMENT_PROBLEM_MASK 1
-int bio_enrollment_add_image(bio_enrollment_t enrollment, bio_image_t image);
-/*
- * Indicates whether there is enough data in the enrollment for it to be
- * converted into a template to be used for identification.
- *
- * Returns 0 for if enrollment does not have enough data yet, 1 if enrollment
- * is complete, or negative error code (such as -EINVAL) on failure.
- *
- */
-int bio_enrollment_is_complete(bio_enrollment_t enrollment);
-/*
- * Returns percent of coverage accumulated during enrollment process.
- * Optional method. Regardless of value returned by this call user should call
- * bio_enrollment_is_complete() to check if algorithm library accumulated enough
- * data to create a template.
- *
- * Returns value in the range 0..100, or negative error (such as -EINVAL);
- */
-int bio_enrollment_get_percent_complete(bio_enrollment_t enrollment);
-/*
- * Indicates that given enrollment process is complete, and algorithm library
- * should generate an active template that can be used in subsequent calls
- * to bio_image_match() and bio_template_serialize() from enrollment data.
- * After the template is created the library should release all resources
- * associated with this enrollment.
- *
- * Argument 'tmpl' is optional and can be set to NULL if caller wishes to
- * abort enrollment process.
- *
- * Returns 0 on success, negative error code (such as -EINVAL) on failure.
- */
-int bio_enrollment_finish(bio_enrollment_t enrollment, bio_template_t *tmpl);
-
-typedef struct {
- int32_t coverage; /* Sensor coverage in range [0..100] */
- int32_t quality; /* Image quality in range [0..100] */
- int32_t min_coverage; /* Minimum coverage accepted by enroll */
- int32_t min_quality; /* Minimum image quality accepted by enroll */
-} bio_image_status_t;
-
-/*
- * Get the image quality and threshold values for a bio_image_t
- *
- * @param[in] image Image data as acquired by
- * fp_sensor_acquire_image_with_mode
- * @param[out] image_status Populated structure with quality/coverage values
- * and corresponding threshold values
- *
- * @note This function will alter the internal states of the bio algorithm
- * library and must not be used during an enroll sequence. The typical
- * use case for this function is to qualify images during image
- * collection.
- *
- * @return negative on error.
- * @return 0 if the quality and coverage threshold values aren't reached.
- * @return 1 if the quality and coverage threshold values are reached.
- */
-int bio_sensor_get_image_status(bio_image_t image,
- bio_image_status_t *image_status);
-
-#endif /* BIOD_BIO_ALGORITHM_H_ */