summaryrefslogtreecommitdiff
path: root/zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml
diff options
context:
space:
mode:
Diffstat (limited to 'zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml')
-rw-r--r--zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml86
1 files changed, 0 insertions, 86 deletions
diff --git a/zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml b/zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml
deleted file mode 100644
index 288dc2d1c8..0000000000
--- a/zephyr/dts/bindings/temp/cros_ec_temp_sensor.yaml
+++ /dev/null
@@ -1,86 +0,0 @@
-# Copyright 2021 The Chromium OS Authors. All rights reserved.
-# Use of this source code is governed by a BSD-style license that can be
-# found in the LICENSE file.
-
-description: >
- Common properties for temperature sensors
- Zero values in degrees K(-273 in degrees C)in thermal thresholds will
- be ignored
-
-compatible: cros-ec,temp-sensor
-
-properties:
- adc:
- required: true
- type: phandle
- description: The named adc channel
-
- thermistor:
- type: phandle
- description: Underlying thermistor device if used
-
- label:
- required: true
- type: string
- description:
- Human-readable string describing the device (used as
- device_get_binding() argument)
-
- enum-name:
- type: string
- required: true
- description:
- Enum values used in the source code to refer to the temperature sensors
- enum:
- - TEMP_SENSOR_CHARGER
- - TEMP_SENSOR_DDR_SOC
- - TEMP_SENSOR_FAN
- - TEMP_SENSOR_PP3300_REGULATOR
-
- temp_fan_off:
- type: int
- description:
- Temperature threshold in degrees C when no active cooling
- is needed
-
- temp_fan_max:
- type: int
- description:
- Temperature threshold in degrees C when max active cooling
- is needed
-
- temp_host_warn:
- type: int
- description:
- Temperature threshold in degrees C of thermal warn.
- Temperatures above the thermal warn threshold generate a
- request to the AP to throttle itself.
-
- temp_host_high:
- type: int
- description:
- Temperature threshold in degrees C of thermal high.
- Temperatures above the thermal high threshold cause the EC to
- assert a signal (usually PROCHOT) to the AP and force the AP to
- throttle.
-
- temp_host_halt:
- type: int
- description:
- Temperature threshold in degrees C that forces AP to shutdown
- due to thermal reason
-
- temp_host_release_warn:
- type: int
- description:
- Temperature release threshold in degrees C of thermal warn
-
- temp_host_release_high:
- type: int
- description:
- Temperature release threshold in degrees C of thermal high
-
- temp_host_release_halt:
- type: int
- description:
- Temperature release threshold in degrees C of thermal shutdown