diff options
Diffstat (limited to 'compiler/msg/errorn.msg')
-rw-r--r-- | compiler/msg/errorn.msg | 2454 |
1 files changed, 2454 insertions, 0 deletions
diff --git a/compiler/msg/errorn.msg b/compiler/msg/errorn.msg new file mode 100644 index 0000000000..57136e56df --- /dev/null +++ b/compiler/msg/errorn.msg @@ -0,0 +1,2454 @@ +%%% Reordering of msg/errorn.msg respective to msg/errore.msg +%%% Contains all comments from msg/errorn.msg +# +# $Id: errorn.msg,v 1.6 2004/01/22 21:19:36 florian Exp $ +# This file is part of the Free Pascal Compiler +# Copyright (c) 1998-2000 by the Free Pascal Development team +# +# Dutch Language File for Free Pascal +# +# See the file COPYING.FPC, included in this distribution, +# for details about the copyright. +# +# This program is distributed in the hope that it will be useful, +# but WITHOUT ANY WARRANTY; without even the implied warranty of +# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. +# +# +# The constants are build in the following order: +# <part>_<type>_<txtidentifier> +# +# <part> is the part of the compiler the message is used +# asmr_ assembler parsing +# asmw_ assembler writing/binary writers +# unit_ unit handling +# scan_ scanner +# parser_ parser +# type_ type checking +# general_ general info +# exec_ calls to assembler, linker, binder +# +# <type> the type of the message it should normally used for +# f_ fatal error +# e_ error +# w_ warning +# n_ note +# h_ hint +# i_ info +# l_ linenumber +# u_ used +# t_ tried +# m_ macro +# p_ procedure +# c_ conditional +# d_ debug message +# b_ display overloaded procedures +# x_ executable informations +# + +# +# Enkele punten om bij het vertalen in het achterhoofd te houden: +# +# - "Methoden" wordt vaak foutief als "methodes" geschreven. +# - "Typen" wordt vaak foutief als "types" geschreven. +# - "Illegal" wordt niet met "illegaal" vertaald, maar met "ongeldig". +# Illegaal betekent onwettig in het Nederlands. +# - Zo wordt "execute" niet met "executeren" vertaalt maar met "uitvoeren". +# Programma, hebt u nog een laatste wens voordat de trekker wordt +# overgehaald? +# - In het Nederlands schrijft men woorden vaker aan elkaar dan in het +# Engels: "compiler switch" (2 woorden) wordt "compileroptie" (1 woord). +# Let ook op voorvoegingen: "Interface and implementation names" wordt: +# "Interface- en implementatienamen" (streepje!) +# - Pas op met het vernederlandsen van Engelse woorden. Bijvoorbeeld +# "identifieerder". Voor deze categorie woorden bestaat geen goede +# vertaling. Iedereen die zo'n vernederlandsing ziet krijgt echter gelijk +# een pijnscheut in zijn taalknobbel. Soms helpt een woordenboek, anders +# is het beter om de engelse term te laten staan. Wat improvisatie helpt +# soms ook, "symbool" is niet precies hetzelfde maar kan in dit geval +# prima als vertaling gebruikt worden. + +# +# General +# +# BeginOfTeX +% \section{General compiler messages} +% This section gives the compiler messages which are not fatal, but which +% display useful information. The number of such messages can be +% controlled with the various verbosity level \var{-v} switches. +% \begin{description} +general_t_compilername=01000_T_Gebruikte compiler: $1 +% When the \var{-vt} switch is used, this line tells you what compiler +% is used. +general_d_sourceos=01001_D_Bronsysteem: $1 +% When the \var{-vd} switch is used, this line tells you what the source +% operating system is. +general_i_targetos=01002_I_Doelsysteem: $1 +% When the \var{-vd} switch is used, this line tells you what the target +% operating system is. +general_t_exepath=01003_T_Programmalocatie: $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for it's binaries. +general_t_unitpath=01004_T_Locatie units: $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for compiled units. You can set this path with the \var{-Fu} +general_t_includepath=01005_T_Locatie includes: $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for it's include files (files used in \var{\{\$I xxx\}} statements). +% You can set this path with the \var{-I} option. +general_t_librarypath=01006_T_Locatie bibliotheken: $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for the libraries. You can set this path with the \var{-Fl} option. +general_t_objectpath=01007_T_Locatie objectbestanden: $1 +% When the \var{-vt} switch is used, this line tells you where the compiler +% looks for object files you link in (files used in \var{\{\$L xxx\}} statements). +% You can set this path with the \var{-Fo} option. +general_i_abslines_compiled=01008_I_$1 Regels gecompileerd, $2 sec. +% When the \var{-vi} switch is used, the compiler reports the number +% of lines compiled, and the time it took to compile them (real time, +% not program time). +general_f_no_memory_left=01009_F_Geen geheugen meer vrij +% The compiler doesn't have enough memory to compile your program. There are +% several remedies for this: +% \begin{itemize} +% \item If you're using the build option of the compiler, try compiling the +% different units manually. +% \item If you're compiling a huge program, split it up in units, and compile +% these separately. +% \item If the previous two don't work, recompile the compiler with a bigger +% heap (you can use the \var{-Ch} option for this, \seeo{Ch}) +% \end{itemize} +% \end{description} +# +# Scanner +# +% \section{Scanner messages.} +% This section lists the messages that the scanner emits. The scanner takes +% care of the lexical structure of the pascal file, i.e. it tries to find +% reserved words, strings, etc. It also takes care of directives and +% conditional compiling handling. +% \begin{description} +general_i_writingresourcefile=01010_I_Schrijven van resource string tabel bestand: $1 +% This message is shown when the compiler writes the Resource String Table +% file containing all the resource strings for a program. +general_e_errorwritingresourcefile=01011_E_Schrijven van resource string tabel bestand: $1 +% This message is shown when the compiler encountered an error when writing +% the Resource String Table file +% \end{description} +# +# Scanner +# +% \section{Scanner messages.} +% This section lists the messages that the scanner emits. The scanner takes +% care of the lexical structure of the pascal file, i.e. it tries to find +% reserved words, strings, etc. It also takes care of directives and +% conditional compiling handling. +% \begin{description} +general_i_fatal=01012_I_Fatale fout: +% Prefix for Fatal Errors +general_i_error=01013_I_Fout: +% Prefix for Errors +general_i_warning=01014_I_Waarschuwing: +% Prefix for Warnings +general_i_note=01015_I_Noot: +% Prefix for Notes +general_i_hint=01016_I_Tip: +% Prefix for Hints +general_e_path_does_not_exist=01017_E_Pad "$1" bestaat niet +% The specified path does not exist. +general_f_compilation_aborted=01018_F_Compilatie afgebroken +% \end{description} +# +# Scanner +# +# 02063 is the last used one +# +% \section{Scanner messages.} +% This section lists the messages that the scanner emits. The scanner takes +% care of the lexical structure of the pascal file, i.e. it tries to find +% reserved words, strings, etc. It also takes care of directives and +% conditional compiling handling. +% \begin{description} +scan_f_end_of_file=02000_F_Onverwacht einde van bestand +% this typically happens in one of the following cases : +% \begin{itemize} +% \item The source file ends before the final \var{end.} statement. This +% happens mostly when the \var{begin} and \var{end} statements aren't +% balanced; +% \item An include file ends in the middle of a statement. +% \item A comment wasn't closed. +% \end{itemize} +scan_f_string_exceeds_line=02001_F_String langer dan regel +% You forgot probably to include the closing ' in a string, so it occupies +% multiple lines. +scan_f_illegal_char=02002_F_ongeldig teken "$1" ($2) +% An illegal character was encountered in the input file. +scan_f_syn_expected=02003_F_Taalfout: $2 verwacht in kolom $1 +% This indicates that the compiler expected a different token than +% the one you typed. It can occur almost everywhere where you make a +% mistake against the pascal language. +scan_t_start_include_file=02004_TL_Ingevoegd bestand $1 word geopend +% When you provide the \var{-vt} switch, the compiler tells you +% when it starts reading an included file. +scan_w_comment_level=02005_W_Commentaar van niveau $1 gevonden +% When the \var{-vw} switch is used, then the compiler warns you if +% it finds nested comments. Nested comments are not allowed in Turbo Pascal +% and can be a possible source of errors. +scan_n_ignored_switch=02008_N_Genegeerde compileroptie $1 +% With \var{-vn} on, the compiler warns if it ignores a switch +scan_w_illegal_switch=02009_W_Foutieve compileroptie $1 +% You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler +% doesn't know. +scan_w_switch_is_global=02010_W_Deze compileroptie heeft ook een globaal effect +% When \var{-vw} is used, the compiler warns if a switch is global. +scan_e_illegal_char_const=02011_E_Foutieve constante voor een karakter +% This happens when you specify a character with its ASCII code, as in +% \var{\#96}, but the number is either illegal, or out of range. The range +% is 1-255. +scan_f_cannot_open_input=02012_F_Kan bestand "$1" niet openen +% \fpc cannot find the program or unit source file you specified on the +% command line. +scan_f_cannot_open_includefile=02013_F_Kan ingevoerd bestand niet openen $1 +% \fpc cannot find the source file you specified in a \var{\{\$include ..\}} +% statement. +scan_e_illegal_pack_records=02015_E_Ongeldige alignatie-aanduiding voor records: "$1" +% You are specifying the \var{\{\$PACKRECORDS n\} } or \var{\{\$ALIGN n\} } +% with an illegal value for \var{n}. For \$PACKRECORDS valid alignments are 1, 2, 4, 8, 16, 32, C, +% NORMAL, DEFAULT, and for \$ALIGN valid alignment are 1, 2, 4, 8, 16, 32, ON, +% OFF. Under mode MacPas \$ALIGN also supports MAC68K, POWER and RESET. +scan_e_illegal_pack_enum=02016_E_Ongeldige enumeratie grootte aanduiding "$1" +% You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for +% \var{n}. Only 1,2,4, NORMAL or DEFAULT are valid here. +scan_e_endif_expected=02017_E_$ENDIF verwacht voor $1 op $2 $3 lijn $4 +% Your conditional compilation statements are unbalanced. +scan_e_preproc_syntax_error=02018_E_Taalfout bij het compileren van een conditionele compilatie uitdrukking +% There is an error in the expression following the \var{\{\$if ..\}} compiler +% directive. +scan_e_error_in_preproc_expr=02019_E_Evalueren van een conditionele compilatie uitdrukking +% There is an error in the expression following the \var{\{\$if ..\}} compiler +% directive. +scan_w_macro_cut_after_255_chars=02020_W_Macro inhoud is afgekapt op 255 karakters voor evaluatie +% The contents of macros cannot be longer than 255 characters. This is a +% safety in the compiler, to prevent buffer overflows. This is shown as a +% warning, i.e. when the \var{-vw} switch is used. +scan_e_endif_without_if=02021_E_ENDIF zonder IF(N)DEF +% Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced. +scan_f_user_defined=02022_F_Gebruiker definitie: $1 +% A user defined fatal error occurred. see also the \progref +scan_e_user_defined=02023_E_Gebruiker definitie: $1 +% A user defined error occurred. see also the \progref +scan_w_user_defined=02024_W_Gebruiker definitie: $1 +% A user defined warning occurred. see also the \progref +scan_n_user_defined=02025_N_Gebruiker definitie: $1 +% A user defined note was encountered. see also the \progref +scan_h_user_defined=02026_H_Gebruiker definitie: $1 +% A user defined hint was encountered. see also the \progref +scan_i_user_defined=02027_I_Gebruiker definitie: $1 +% User defined information was encountered. see also the \progref +scan_e_keyword_cant_be_a_macro=02028_E_Sleutelwoord herdefinieren als macro heeft geen effect +% You cannot redefine keywords with macros. +scan_f_macro_buffer_overflow=02029_F_Macro buffer overflow bij lezen of expansie van macro +% Your macro or it's result was too long for the compiler. +scan_w_macro_too_deep=02030_W_Uitwerken van macros heeft niveau 16 overschreden +% When expanding a macro, macros have been nested to a level of 16. +% The compiler will expand no further, since this may be a sign that +% recursion is used. +scan_w_wrong_styled_switch=02031_W_Compiler opties in delphi commentaar stijl zijn niet ondersteund +% Compiler switches should be in normal pascal style comments. +scan_d_handling_switch=02032_DL_Behandel schakelaar "$1" +% When you set debugging info on (\var{-vd}) the compiler tells you when it +% is evaluating conditional compile statements. +scan_c_endif_found=02033_CL_ENDIF $1 gevonden +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifdef_found=02034_CL_IFDEF $1 gevonden, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifopt_found=02035_CL_IFOPT $1 gevonden, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_if_found=02036_CL_IF $1 gevonden, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_ifndef_found=02037_CL_IFNDEF $1 gevonden, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_else_found=02038_CL_ELSE $1 gevonden, $2 +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements. +scan_c_skipping_until=02039_CL_Negeer tot... +% When you turn on conditional messages(\var{-vc}), the compiler tells you +% where it encounters conditional statements, and whether it is skipping or +% compiling parts. +scan_i_press_enter=02040_I_Druk <return> om verder te gaan +% When the \var{-vi} switch is used, the compiler stops compilation +% and waits for the \var{Enter} key to be pressed when it encounters +% a \var{\{\$STOP\}} directive. +scan_w_unsupported_switch=02041_W_Niet ondersteunde optie $1 +% When warings are turned on (\var{-vw}) the compiler warns you about +% unsupported switches. This means that the switch is used in Delphi or +% Turbo Pascal, but not in \fpc +scan_w_illegal_directive=02042_W_Ongeldige compiler optie $1 +% When warings are turned on (\var{-vw}) the compiler warns you about +% unrecognised switches. For a list of recognised switches, \progref +scan_t_back_in=02043_TL_Terug in $1 +% When you use (\var{-vt}) the compiler tells you when it has finished +% reading an include file. +% +% +% +scan_w_unsupported_app_type=02044_W_Niet ondersteund programmatype: $1 +% It is not possible to switch from one assembler reader to another +% inside an assmebler block. The new reader will be used for next +% assembler statement only. +scan_w_app_type_not_support=02045_W_$APPTYPE niet ondersteund op doelsysteem +% The \var{\{\$APPTYPE\}} directive is supported by win32 applications only. +scan_w_description_not_support=02046_W_DESCRIPTIION is niet ondersteund op het geselecteerde OS +% The \var{\{\$DESCRIPTION\}} directive is not supported on this target OS +scan_n_version_not_support=02047_N_VERSION is niet ondersteund door het doel OS. +% The \var{\{\$VERSION\}} directive is only supported by win32 target. +scan_n_only_exe_version=02048_N_VERSION kan alleen voor executables of bibliotheken +% The \var{\{\$VERSION\}} directive is only used for executable or DLL sources. +scan_w_wrong_version_ignored=02049_W_verkeerd formaat voor VERSION directive $1 +% The \var{\{\$VERSION\}} directive format is major_version.minor_version +% where major_version and minor_version are words. +scan_e_illegal_asmmode_specifier=02050_E_Ongeldige assembler-stijl opgegeven: "$1" +% When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}} +% the compiler didn't recognize the mode you specified. +scan_w_no_asm_reader_switch_inside_asm=02051_W_ASM lezer-optie is niet mogelijk in een asm instructie, $1 ingesteld voor volgende blok +% It is not possible to switch from one assembler reader to another +% inside an assmebler block. The new reader will be used for next +% assembler statement only. +scan_e_wrong_switch_toggle=02052_E_Verkeerde optiewaarde, gebruik ON/OFF of +/- +% You need to use ON or OFF or a + or - to toggle the switch +scan_e_resourcefiles_not_supported=02053_E_Resource bestanden worden niet ondersteund op doel OS +% The target you are compiling for doesn't support Resource files. The +% only target which can use resource files is Win32 +% +% \end{description} +# +# Parser +# +% \section{Parser messages} +% This section lists all parser messages. The parser takes care of the +% semantics of you language, i.e. it determines if your pascal constructs +% are correct. +% \begin{description} +scan_w_include_env_not_found=02054_W_Include omgevingsvariabele $1 niet gevonden in omgeving +% The included environment variable can't be found in the environment, it'll +% be replaced by an empty string instead. +scan_e_invalid_maxfpureg_value=02055_E_Ongeldige waarde voor FPU register limiet +% Valid values for this directive are 0..8 and NORMAL/DEFAULT +% \end{description} +# +# Parser +# +% \section{Parser messages} +% This section lists all parser messages. The parser takes care of the +% semantics of you language, i.e. it determines if your pascal constructs +% are correct. +% \begin{description} +scan_w_only_one_resourcefile_supported=02056_W_Slechts 1 resource bestand ondersteund voor dit operating systeem. +% The target you are compiling for supports only one resource file. This is the +% case of OS/2 (EMX) currently. The first resource file found is used, the +% others are discarded. +% \end{description} +# +# Parser +# +% \section{Parser messages} +% This section lists all parser messages. The parser takes care of the +% semantics of you language, i.e. it determines if your pascal constructs +% are correct. +% \begin{description} +scan_w_macro_support_turned_off=02057_W_Macro ondersteuning is uitgeschakeld +% A macro declaration has been found, but macro support is currently off, +% so the declaration will be ignored. To turn macro support on compile with +% -Sm on the commandline or add \{\$MACRO ON\} in the source +scan_e_invalid_interface_type=02058_E_Ongeldig interface type opgegeven. Geldige waarden zijn COM, CORBA of DEFAULT +% The interface type that was specified is not supported +scan_w_appid_not_support=02059_W_APPID is slechts ondersteund op PalmOS +% The \var{\{\$APPID\}} directive is only supported for the PalmOS target. +scan_w_appname_not_support=02060_W_APPNAME is slechts ondersteund op PalmOS +% The \var{\{\$APPNAME\}} directive is only supported for the PalmOS target. +scan_e_string_exceeds_255_chars=02061_E_Constante tekenreeksen (strings) kunnen niet langer dan 255 karakters zijn. +% A single string constant can contain at most 255 chars. Try splitting up the +% string in multiple smaller parts and concatenate them with a + operator. +scan_f_include_deep_ten=02062_F_Include bestanden kunnen maar tot op 16 niveaus genest worden +% When including include files the files have been nested to a level of 16. +% The compiler will expand no further, since this may be a sign that +% recursion is used. +scan_e_too_many_push=02063_F_Te veel PUSH niveaus +% A maximum of 20 levels is allowed. This error occur only in mode MacPas. +scan_e_too_many_pop=02064_E_POP instructie zonder voorafgaande PUSH instructie +% This error occur only in mode MacPas. +scan_e_error_macro_lacks_value=02065_E_Macro of compilatie-variabele "$1" heeft geen waarde +% Thus the conditional compile time expression cannot be evaluated. +scan_e_wrong_switch_toggle_default=02066_E_Verkeerde schakel-waarde. Gebruik ON/OFF/DEFAULT of +/-/* +% You need to use ON or OFF or DEFAULT or a + or - or * to toggle the switch +scan_e_mode_switch_not_allowed=02067_E_MODE schakel "$1" is niet toegestaan op deze plaats. +% A mode switch has already been encountered, or, in case of option -Mmacpas, +% a mode switch occur after UNIT. +scan_e_error_macro_undefined=02068_E_Macro of compilatie-variabele "$1" is niet gedefinieerd +% Thus the conditional compile time expression cannot be evaluated. Only in mode MacPas. +scan_e_utf8_bigger_than_65535=02069_E_UTF-8 code groter dan 65535 gevonden +% \fpc handles utf-8 strings internally as widestrings e.g. the char codes are limited to 65535 +scan_e_utf8_malformed=02070_E_Ongeldige UTF-8 tekenreeks +% The given string isn't a valid UTF-8 string +scan_c_switching_to_utf8=02071_C_UTF-8 handtekening gevonden, gebruik UTF-8 codering +% The compiler found an UTF-8 encoding signature (\$ef, \$bb, \$bf) at the beginning of a file, +% so it interprets it as an UTF-8 file +scan_e_compile_time_typeerror=02072_E_Compilatie-expressie: "$1" gevraagd, maar kreeg "$2" op "$3" +% Type check of a compile time expression failed. +% \end{description} +# +# Parser +# +# 03192 is the last used one +# +% \section{Parser messages} +% This section lists all parser messages. The parser takes care of the +% semantics of you language, i.e. it determines if your pascal constructs +% are correct. +% \begin{description} +parser_e_syntax_error=03000_E_Parser - Taalfout +% An error against the Turbo Pascal language was encountered. This happens +% typically when an illegal character is found in the sources file. +parser_e_dont_nest_interrupt=03004_E_INTERRUPT procedures kunnen niet genest worden +% An \VAR{INTERRUPT} procedure must be global. +parser_w_proc_directive_ignored=03005_W_Procedure type $1 ignored +% This is a warning. \var{REGISTER},\var{REINTRODUCE} is ignored by FPC programs for now. +% This is introduced first for Delphi compatibility. +parser_e_no_overload_for_all_procs=03006_E_Not all declarations of $1 are declared with OVERLOAD +% When you want to use overloading using the \var{OVERLOAD} directive, then +% all declarations need to have \var{OVERLOAD} specified. +parser_e_export_name_double=03008_E_Dubbel geexporteerde functienaam $1 +% Exported function names inside a specific DLL must all be different +parser_e_export_ordinal_double=03009_E_Dubbel geexporteerde functie index $1 +% Exported function names inside a specific DLL must all be different +parser_e_export_invalid_index=03010_E_Ongeldige index for geexporteerde functie +% DLL function index must be in the range \var{1..\$FFFF} +parser_w_parser_reloc_no_debug=03011_W_Relocatable bibliotheek of applicatie $1 debug informatie niet ondersteund. +parser_w_parser_win32_debug_needs_WN=03012_W_Om win32 code te debuggen moet relocatie afgezet worden door de -WN optie +% Stabs info is wrong for relocatable DLL or EXES use -WN +% if you want to debug win32 executables. +parser_e_constructorname_must_be_init=03013_E_Constructornaam moet INIT zijn +% You are declaring a constructor with a name which isn't \var{init}, and the +% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). +parser_e_destructorname_must_be_done=03014_E_Destructornaam moet DONE zijn +% You are declaring a constructor with a name which isn't \var{done}, and the +% \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}). +parser_e_proc_inline_not_supported=03016_E_Procedure type INLINE wordt niet ondersteund +% You tried to compile a program with C++ style inlining, and forgot to +% specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++ +% styled inlining by default. +parser_w_constructor_should_be_public=03018_W_Constructor mag niet private or protected zijn +% Constructors must be in the 'public' part of an object (class) declaration. +parser_w_destructor_should_be_public=03019_W_Destructor mag niet private or protected zijn +% Destructors must be in the 'public' part of an object (class) declaration. +parser_n_only_one_destructor=03020_N_Klasse heeft slechts 1 destructor +% You can declare only one destructor for a class. +parser_e_no_local_objects=03021_E_Lokale klassedefinities zijn niet toegestaan +% Classes must be defined globally. They cannot be defined inside a +% procedure or function +parser_f_no_anonym_objects=03022_F_Anonieme klassedefinities zijn niet toegestaan +% An invalid object (class) declaration was encountered, i.e. an +% object or class without methods that isn't derived from another object or +% class. For example: +% \begin{verbatim} +% Type o = object +% a : longint; +% end; +% \end{verbatim} +% will trigger this error. +parser_n_object_has_no_vmt=03023_N_Het object "$1Ã" heeft geen VMT +% This is a note indicating that the declared object has no +% virtual method table. +parser_e_illegal_parameter_list=03024_E_Foutieve parameterlijst +% You are calling a function with parameters that are of a different type than +% the declared parameters of the function. +parser_e_wrong_parameter_size=03026_E_Onjuist aantal parameters meegegeven +% There is an error in the parameter list of the function or procedure, +% the number of parameters is not correct. +parser_e_overloaded_no_procedure=03027_E_Overladen symbool "$1" is geen procedure of functie +% The compiler encountered a symbol with the same name as an overloaded +% function, but it isn't a function it can overload. +parser_e_overloaded_have_same_parameters=03028_E_Overroepen procedures hebben identieke parameterlijst +% You're declaring overloaded functions, but with the same parameter list. +% Overloaded function must have at least 1 different parameter in their +% declaration. +parser_e_header_dont_match_forward=03029_E_Declaratie komt niet overeen met eerdere declaratie: $1 +% You declared a function with same parameters but +% different result type or function specifiers. +parser_e_header_different_var_names=03030_E_Procedurehoofding $1 komt niet overeen met eerdere declaratie: variabelenaam veranderd $2 => $3 +% You declared the function in the \var{interface} part, or with the +% \var{forward} directive, but define it with a different parameter list. +parser_n_duplicate_enum=03031_N_Waarden in opsommingstypes moeten steeds stijgen +% \fpc allows enumeration constructions as in C. Given the following +% declaration two declarations: +% \begin{verbatim} +% type a = (A_A,A_B,A_E:=6,A_UAS:=200); +% type a = (A_A,A_B,A_E:=6,A_UAS:=4); +% \end{verbatim} +% The second declaration would produce an error. \var{A\_UAS} needs to have a +% value higher than \var{A\_E}, i.e. at least 7. +parser_e_no_with_for_variable_in_other_segments=03033_E_With kan niet gebruikt worden voor variabelen in verschillende segmenten +% With stores a variable locally on the stack, +% but this is not possible if the variable belongs to another segment. +parser_e_too_much_lexlevel=03034_E_Procedure meer dan 31 keer genest +% You can nest function definitions only 31 times. +parser_e_range_check_error=03035_E_Bereikfout bij evalueren constanten +% The constants are out of their allowed range. +parser_w_range_check_error=03036_W_Bereikscontrolefout bij evalueren constantes. +% The constants are out of their allowed range. +parser_e_double_caselabel=03037_E_Dubbel case-element +% You are specifying the same label 2 times in a \var{case} statement. +parser_e_case_lower_less_than_upper_bound=03038_E_Bovengrens van casebereik is lager dan ondergrens +% The upper bound of a \var{case} label is less than the lower bound and this +% is useless +parser_e_type_const_not_possible=03039_E_Getypeerde constanten van klassen zijn niet toegestaan +% You cannot declare a constant of type class or object. +parser_e_no_overloaded_procvars=03040_E_Procedurele variabelen van overroepen procedures zijn niet toegestaan +% You are trying to assign an overloaded function to a procedural variable. +% This isn't allowed. +parser_e_invalid_string_size=03041_E_Stringlengte moet tussen 1 en 255 liggen +% The length of a string in Pascal is limited to 255 characters. You are +% trying to declare a string with length lower than 1 or greater than 255 +% (This is not true for \var{Longstrings} and \var{AnsiStrings}. +parser_w_use_extended_syntax_for_objects=03042_W_Gebruik de uitgebreide syntax van DISPOSE en NEW om nieuwe instanties van klassen te genereren +% If you have a pointer \var{a} to a class type, then the statement +% \var{new(a)} will not initialize the class (i.e. the constructor isn't +% called), although space will be allocated. you should issue the +% \var{new(a,init)} statement. This will allocate space, and call the +% constructor of the class. +parser_w_no_new_dispose_on_void_pointers=03043_W_Het gebruik van NEW of DISPOSE voor pointers zonder type is zinloos +parser_e_no_new_dispose_on_void_pointers=03044_E_Het gebruik van NEW of DISPOSE is niet mogelijk voor pointers zonder type +% You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer +% because no size is associated to an untyped pointer. +% Accepted for compatibility in \var{tp} and \var{delphi} modes. +parser_e_class_id_expected=03045_E_Klasse verwacht +% This happens when the compiler scans a procedure declaration that contains +% a dot, +% i.e., a object or class method, but the type in front of the dot is not +% a known type. +parser_e_no_type_not_allowed_here=03046_E_Typesymbool is hier niet toegestaan +% You cannot use a type inside an expression. +parser_e_methode_id_expected=03047_E_Methode verwacht +% This identifier is not a method. +% This happens when the compiler scans a procedure declaration that contains +% a dot, i.e., a object or class method, but the procedure name is not a +% procedure of this type. +parser_e_header_dont_match_any_member=03048_E_Proceduredeclaratie komt niet overeen met een methode van deze klasse $1 +% This identifier is not a method. +% This happens when the compiler scans a procedure declaration that contains +% a dot, i.e., a object or class method, but the procedure name is not a +% procedure of this type. +parser_d_procedure_start=03049_DL_procedure/functie $1 +% When using the \var{-vd} switch, the compiler tells you when it starts +% processing a procedure or function implementation. +parser_e_error_in_real=03050_E_Foutieve vlottende-komma constante +% The compiler expects a floating point expression, and gets something else. +parser_e_fail_only_in_constructor=03051_E_FAIL mag alleen in constructors gebruikt worden +% You are using the \var{FAIL} instruction outside a constructor method. +parser_e_no_paras_for_destructor=03052_E_Destructors hebben geen parameters +% You are declaring a destructor with a parameter list. Destructor methods +% cannot have parameters. +parser_e_only_class_methods_via_class_ref=03053_E_Alleen klassemethoden kunnen gerefereerd worden via een klasse +% This error occurs in a situation like the following: +% \begin{verbatim} +% Type : +% Tclass = Class of Tobject; +% +% Var C : TClass; +% +% begin +% ... +% C.free +% \end{verbatim} +% \var{Free} is not a class method and hence cannot be called with a class +% reference. +parser_e_only_class_methods=03054_E_Alleen klassemethoden zijn toegankelijk in klassen +% This is related to the previous error. You cannot call a method of an object +% from a inside a class method. The following code would produce this error: +% \begin{verbatim} +% class procedure tobject.x; +% +% begin +% free +% \end{verbatim} +% Because free is a normal method of a class it cannot be called from a class +% method. +parser_e_case_mismatch=03055_E_Type van constante komt niet overeen met dat van de case uitrukking +% One of the labels is not of the same type as the case variable. +parser_e_illegal_symbol_exported=03056_E_Het symbool kan niet uitgevoerd worden uit een bibliotheek +% You can only export procedures and functions when you write a library. You +% cannot export variables or constants. +parser_w_should_use_override=03057_W_Een virtuele methode moet met OVERRIDE overroepen worden: $1 +% A method that is declared \var{virtual} in a parent class, should be +% overridden in the descendent class with the \var{override} directive. If you +% don't specify the \var{override} directive, you will hide the parent method; +% you will not override it. +parser_e_nothing_to_be_overridden=03058_E_Er is geen geerfde methode die overroepen kan worden: $1 +% You try to \var{override} a virtual method of a parent class that doesn't +% exist. +parser_e_no_procedure_to_access_property=03059_E_Er is geen lid om de eigenschap te bereiken +% You specified no \var{read} directive for a property. +parser_w_stored_not_implemented=03060_W_Stored prorperty directive is not yet implemented +% The \var{stored} directive is not yet implemented +parser_e_ill_property_access_sym=03061_E_Ongeldig symbool voor eigenschaptoegang +% There is an error in the \var{read} or \var{write} directives for an array +% property. When you declare an array property, you can only access it with +% procedures and functions. The following code woud cause such an error. +% \begin{verbatim} +% tmyobject = class +% i : integer; +% property x [i : integer]: integer read I write i; +% \end{verbatim} +% +parser_e_cant_access_protected_member=03062_E_Kan niet in beschermd veld van een object schrijven +% Fields that are declared in a \var{protected} section of an object or class +% declaration cannot be accessed outside the module wher the object is +% defined, or outside descendent object methods. +parser_e_cant_access_private_member=03063_E_Kan niet in prive-veld van een object schrijven +% Fields that are declared in a \var{private} section of an object or class +% declaration cannot be accessed outside the module where the class is +% defined. +parser_e_overridden_methods_not_same_ret=03066_E_Overridden methodes moeten dezelfde resultaat type hebben: "$2" wordt overridden door Ã"1$1" met een ander type +% If you declare overridden methods in a class definition, they must +% have the same return type. +parser_e_dont_nest_export=03067_E_Als EXPORT gedeclareerde procedures kunnen niet genest worden +% You cannot declare a function or procedure within a function or procedure +% that was declared as an export procedure. +parser_e_methods_dont_be_export=03068_E_Methoden kunnen niet geexporteerd worden. +% You cannot declare a procedure that is a method for an object as +% \var{export}ed. That is, your methods cannot be called from a C program. +parser_e_call_by_ref_without_typeconv=03069_E_Typen van referentieparameters moeten exact overeenkomen. "$1" gekregen, "$2" verwacht. +% When calling a function declared with \var{var} parameters, the variables in +% the function call must be of exactly the same type. There is no automatic +% type conversion. +parser_e_no_super_class=03070_E_Deze klasse is geen ouderklasse van de huidige klasse +% When calling inherited methods, you are trying to call a method of a strange +% class. You can only call an inherited method of a parent class. +parser_e_self_not_in_method=03071_E_SELF is alleen toegelaten in methoden. +% You are trying to use the \var{self} parameter outside an object's method. +% Only methods get passed the \var{self} parameters. +parser_e_generic_methods_only_in_methods=03072_E_Methoden kunnen alleen in andere methoden worden aangeroepen met type symbool +% A construction like \var{sometype.somemethod} is only allowed in a method. +parser_e_illegal_colon_qualifier=03073_E_Ongeldig gebruik van ':' +% You are using the format \var{:} (colon) 2 times on an expression that +% is not a real expression. +parser_e_illegal_set_expr=03074_E_Bereikfout in setconstructor of dubbel setelement +% The declaration of a set contains an error. Either one of the elements is +% outside the range of the set type, either two of the elements are in fact +% the same. +parser_e_pointer_to_class_expected=03075_E_Pointer naar klasse verwacht +% You specified an illegal type in a \var{New} statement. +% The extended synax of \var{New} needs an object as a parameter. +parser_e_expr_have_to_be_constructor_call=03076_E_Uitdrukking moet een constructoraanroep zijn. +% When using the extended syntax of \var{new}, you must specify the constructor +% method of the object you are trying to create. The procedure you specified +% is not a constructor. +parser_e_expr_have_to_be_destructor_call=03077_E_Uitdrukking moet een destructoraanroep zijn +% When using the extended syntax of \var{dispose}, you must specify the +% destructor method of the object you are trying to dispose of. +% The procedure you specified is not a destructor. +parser_e_invalid_record_const=03078_E_Ongeldige volgorde van record leden +% When declaring a constant record, you specified the fields in the wrong +% order. +parser_e_false_with_expr=03079_E_Type van uitdrukking moet class of record type zijn +% A \var{with} statement needs an argument that is of the type \var{record} +% or \var{class}. You are using \var{with} on an expression that is not of +% this type. +parser_e_void_function=03080_E_Procedures kunnen geen resultaat teruggeven +% In \fpc, you can specify a return value for a function when using +% the \var{exit} statement. This error occurs when you try to do this with a +% procedure. Procedures cannot return a value. +parser_e_constructors_always_objects=03081_E_Constructors en destructors moeten methoden zijn +% You're declaring a procedure as destructor or constructor, when the +% procedure isn't a class method. +parser_e_operator_not_overloaded=03082_E_Operator is niet hergedefineerd +% You're trying to use an overloaded operator when it isn't overloaded for +% this type. +parser_e_no_such_assignment=03083_E_Het is niet toegestaan de toewijzingsoperator te overroepen voor gelijke typen +% You can not overload assignment for types +% that the compiler considers as equal. +parser_e_overload_impossible=03084_E_Het overroepen van deze operator is onmogelijk +% The combination of operator, arguments and return type are +% incompatible. +parser_e_no_reraise_possible=03085_E_Re-raise is hier niet mogelijk +% You are trying to raise an exception where it isn't allowed. You can only +% raise exceptions in an \var{except} block. +parser_e_no_new_or_dispose_for_classes=03086_E_De uitgebreide syntax van NEW of DISPOSE is niet toegestaan voor klassen +% You cannot generate an instance of a class with the extended syntax of +% \var{new}. The constructor must be used for that. For the same reason, you +% cannot call \var{Dispose} to de-allocate an instance of a class, the +% destructor must be used for that. +parser_e_procedure_overloading_is_off=03088_E_Procedure overroepen is afgezet +% When using the \var{-So} switch, procedure overloading is switched off. +% Turbo Pascal does not support function overloading. +parser_e_overload_operator_failed=03089_E_Deze operator kan niet overroepen worden. +% You are trying to overload an operator which cannot be overloaded. +% The following operators can be overloaded : +% \begin{verbatim} +% +, -, *, /, =, >, <, <=, >=, is, as, in, **, := +% \end{verbatim} +parser_e_comparative_operator_return_boolean=03090_E_Vergelijkingsoperator moet een boolean type als resultaat hebben. +% When overloading the \var{=} operator, the function must return a boolean +% value. +parser_e_only_virtual_methods_abstract=03091_E_Enkel virtuele methoden kunnen abstract zijn +% You are declaring a method as abstract, when it isn't declared to be +% virtual. +parser_f_unsupported_feature=03092_F_Gebruik van niet ondersteunde functionaliteit! +% You're trying to force the compiler into doing something it cannot do yet. +parser_e_mix_of_classes_and_objects=03093_E_CLASSES and OBJECTS kunnen niet gemengd worden. +% You cannot derive \var{objects} and \var{classes} intertwined . That is, +% a class cannot have an object as parent and vice versa. +parser_w_unknown_proc_directive_ignored=03094_W_Onbekende proceduredirective is genegeerd: $1 +% The procedure direcive you secified is unknown. Recognised procedure +% directives are \var{cdecl}, \var{stdcall}, \var{popstack}, \var{pascal} +% \var{register}, \var{export}. +parser_e_absolute_only_one_var=03095_E_Absolute kan maar aan een variabele verbonden worden. +% You cannot specify more than one variable before the \var{absolute} directive. +% Thus, the following construct will provide this error: +% \begin{verbatim} +% Var Z : Longint; +% X,Y : Longint absolute Z; +% \end{verbatim} +% \item [ absolute can only be associated a var or const ] +% The address of a \var{absolute} directive can only point to a variable or +% constant. Therefore, the following code will produce this error: +% \begin{verbatim} +% Procedure X; +% +% var p : longint absolute x; +% \end{verbatim} +% +parser_e_absolute_only_to_var_or_const=03096_E_Absolute kan slechts aan variabelen of constanten verbonden worden. +% The address of a \var{absolute} directive can only point to a variable or +% constant. Therefore, the following code will produce this error: +% \begin{verbatim} +% Procedure X; +% +% var p : longint absolute x; +% \end{verbatim} +% +parser_e_initialized_only_one_var=03097_E_Slechts 1 variabele kan geinitialiseerd worden. +% You cannot specify more than one variable with a initial value +% in Delphi syntax. +parser_e_abstract_no_definition=03098_E_Abtracte methoden kunnen niet gedefineerd worden +% Abstract methods can only be declared, you cannot implement them. They +% should be overridden by a descendant class. +parser_e_overloaded_must_be_all_global=03099_E_Deze overroepen procedure kan niet lokaal zijn (moet geexporteerd worden) +% You are defining a overloaded function in the implementation part of a unit, +% but there is no corresponding declaration in the interface part of the unit. +parser_w_virtual_without_constructor=03100_W_Gebruik van virtuele methoden zonder constructor in "$1" +% If you declare objects or classes that contain virtual methods, you need +% to have a constructor and destructor to initialize them. The compiler +% encountered an object or class with virtual methods that doesn't have +% a constructor/destructor pair. +parser_c_macro_defined=03101_CL_Macro gedefinieerd: $1 +% When \var{-vc} is used, the compiler tells you when it defines macros. +parser_c_macro_undefined=03102_CL_Macro definitie verwijderd: $1 +% When \var{-vc} is used, the compiler tells you when it undefines macros. +parser_c_macro_set_to=03103_CL_Macro $1 heeft waarde $2 gekregen +% When \var{-vc} is used, the compiler tells you what values macros get. +parser_i_compiling=03104_I_Compilatie van $1 +% When you turn on information messages (\var{-vi}), the compiler tells you +% what units it is recompiling. +parser_u_parsing_interface=03105_UL_Parsen van de interface van unit $1 +% This tells you that the reading of the interface +% of the current unit starts +parser_u_parsing_implementation=03106_UL_Parsen van de implementatie van unit $1 +% This tells you that the code reading of the implementation +% of the current unit, library or program starts +parser_d_compiling_second_time=03107_DL_Compilatie van $1 voor de tweede keer. +% When you request debug messages (\var{-vd}) the compiler tells you what +% units it recompiles for the second time. +parser_e_no_property_found_to_override=03109_E_Geen eigenschap gevonden om te herdefinieren +% You want to overrride a property of a parent class, when there is, in fact, +% no such property in the parent class. +parser_e_only_one_default_property=03110_E_Slechts 1 standaardeigenschap is toegestaan, geerfde standaardeigenschap in kind gevonden. +% You specified a property as \var{Default}, but a parent class already has a +% default property, and a class can have only one default property. +parser_e_property_need_paras=03111_E_Standaardeigenschappen moeten van type array zijn. +% Only array properties of classes can be made \var{default} properties. +parser_e_constructor_cannot_be_not_virtual=03112_E_Virtuele constructors worden alleen ondersteunt in het klassemodel +% You cannot have virtual constructors in objects. You can only have them +% in classes. +parser_e_no_default_property_available=03113_E_Geen standaardeigenschap gevonden +% You try to access a default property of a class, but this class (or one of +% it's ancestors) doesn't have a default property. +parser_e_cant_have_published=03114_E_De klasse kan geen gepubliceerde sectie hebben, gebruik {$M+} +% If you want a \var{published} section in a class definition, you must +% use the \var{\{\$M+\}} switch, whch turns on generation of type +% information. +parser_e_forward_declaration_must_be_resolved=03115_E_Declaratie van klasse $1 moet worden opgelost om de klasse als ouder te gebruiken +% To be able to use an object as an ancestor object, it must be defined +% first. This error occurs in the following situation: +% \begin{verbatim} +% Type ParentClas = Class; +% ChildClass = Class(ParentClass) +% ... +% end; +% \end{verbatim} +% Where \var{ParentClass} is declared but not defined. +parser_e_no_local_operator=03116_E_Lokale operatoren worden niet ondersteund +% You cannot overload locally, i.e. inside procedures or function +% definitions. +parser_e_proc_dir_not_allowed_in_interface=03117_E_Procedure directive $1 niet toegestaan in interfacesectie +% This procedure directive is not allowed in the \var{interface} section of +% a unit. You can only use it in the \var{implementation} section. +parser_e_proc_dir_not_allowed_in_implementation=03118_E_Procedure directive $1 niet toegestaan in implementatiesectie +% This procedure directive is not defined in the \var{implementation} section of +% a unit. You can only use it in the \var{interface} section. +parser_e_proc_dir_not_allowed_in_procvar=03119_E_Procedure directive $1 niet toegestaan in procvar declaratie +% This procedure directive cannot be part of a procedural of function +% type declaration. +parser_e_function_already_declared_public_forward=03120_E_Functie is al publiek/forward gedeclareerd $1 +% You will get this error if a function is defined as \var{forward} twice. +% Or it is once in the \var{interface} section, and once as a \var{forward} +% declaration in the \var{implmentation} section. +parser_e_not_external_and_export=03121_E_Kan niet zowel EXPORT als EXTERNAL gebruiken +% These two procedure directives are mutually exclusive +parser_w_not_supported_for_inline=03123_W_$1 wordt niet ondersteund voor inline procedure/functie +% Inline procedures don't support this declaration. +parser_w_inlining_disabled=03124_W_Inlining uitgeschakeld +% Inlining of procedures is disabled. +parser_i_writing_browser_log=03125_I_Schrijven van browser logfile $1 +% When information messages are on, the compiler warns you when it +% writes the browser log (generated with the \var{\{\$Y+ \}} switch). +parser_h_maybe_deref_caret_missing=03126_H_misschien is het een pointer, ^ ontbreekt dan +% The compiler thinks that a pointer may need a dereference. +parser_f_assembler_reader_not_supported=03127_F_Geselecteerde assemblerlezer wordt niet ondersteund +% The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not +% supported. The compiler can be compiled with or without support for a +% particular assembler reader. +parser_e_proc_dir_conflict=03128_E_Procedure directive $1 geeft conflicten met andere directives +% You specified a procedure directive that conflicts with other directives. +% for instance \var{cdecl} and \var{pascal} are mutually exclusive. +parser_e_call_convention_dont_match_forward=03129_E_Aanroep conventie klopt niet met voorwaartse +% This error happens when you declare a function or procedure with +% e.g. \var{cdecl;} but omit this directive in the implementation, or vice +% versa. The calling convention is part of the function declaration, and +% must be repeated in the function definition. +parser_e_property_cant_have_a_default_value=03131_E_Eigenschap kan geen standaard waarde hebben +% Set properties or indexed properties cannot have a default value. +parser_e_property_default_value_must_const=03132_E_De standaard waarde van een eigenschap moet een constante zijn +% The value of a \var{default} declared property must be knwon at compile +% time. The value you specified is only known at run time. This happens +% .e.g. if you specify a variable name as a default value. +parser_e_cant_publish_that=03133_E_Symbool kan niet worden gepubliceerd, alleen mogelijk voor een klasse +% Only class type variables can be in a \var{published} section of a class +% if they are not declared as a property. +parser_e_cant_publish_that_property=03134_E_Dit soort eigenschappen kunnen niet worden gepubliceerd +% Properties in a \var{published} section cannot be array properties. +% they must be moved to public sections. Properties in a \var{published} +% section must be an ordinal type, a real type, strings or sets. +parser_e_empty_import_name=03136_E_Lege importnaam opgegeven +% Some targets need a name for the imported procedure or a cdecl specifier +parser_e_division_by_zero=03138_E_Deling door nul +% There is a divsion by zero encounted +parser_e_invalid_float_operation=03139_E_Ongeldige vlottende-komma bewerking. +% An operation on two real type values produced an overflow or a division +% by zero. +parser_e_array_lower_less_than_upper_bound=03140_E_Bovengrens van bereik is lager dan ondergrens +% The upper bound of a \var{case} label is less than the lower bound and this +% is not possible +parser_w_string_too_long=03141_W_string "$1" is langer dan $2 +% The size of the constant string is larger than the size you specified in +% string type definition +parser_e_string_larger_array=03142_E_Stringlengte moet tussen 1 en 255 liggen +% The size of the constant string is larger than the size you specified in +% the array[x..y] of char definition +parser_e_ill_msg_expr=03143_E_Ongeldige uitdrukking achter message optie +% \fpc supports only integer or string values as message constants +parser_e_ill_msg_param=03144_E_Message handlers aanvaarden slechts 1 variabele parameter +% A method declared with the \var{message}-directive as message handler +% can take only one parameter which must be declared as call by reference +% Parameters are declared as call by reference using the \var{var}-directive +parser_e_duplicate_message_label=03145_E_Dubbel message label: $1 +% A label for a message is used twice in one object/class +parser_e_self_in_non_message_handler=03146_E_Self kan alleen een explicite parameter zijn bij string message handlers +% The self parameter can be passed only explicit if it is a method which +% is declared as message method handler +parser_e_threadvars_only_sg=03147_E_Threadvariabelen kunnen alleen globaal of statisch zijn +% Threadvars must be static or global, you can't declare a thread +% local to a procedure. Local variables are always local to a thread, +% because every thread has it's own stack and local variables +% are stored on the stack +parser_f_direct_assembler_not_allowed=03148_F_Directe assemblercode wordt niet ondersteund door de interne assembler. +% You can't use direct assembler when using a binary writer, choose an +% other outputformat or use an other assembler reader +parser_w_no_objpas_use_mode=03149_W_Laad de OBJPAS unit niet manueel, gebruik {$mode objfpc} of {$mode delphi}. +% You're trying to load the ObjPas unit manual from a uses clause. This is +% not a good idea to do, you can better use the \var{\{\$mode objfpc\}} or +% \var{\{\$mode delphi\}} +% directives which load the unit automaticly +parser_e_no_object_override=03150_E_OVERRIDE kan niet gebruikt worden in objecten +% Override isn't support for objects, use VIRTUAL instead to override +% a method of an anchestor object +parser_e_cant_use_inittable_here=03151_E_Datatypen die initializatie/finalizatie vereisen zijn niet toegestaan in variabele records. +% Some data type (e.g. \var{ansistring}) needs initialization/finalization +% code which is implicitly generated by the compiler. Such data types +% can't be used in the variant part of a record. +% \end{description} +# +# Type Checking +# +% \section{Type checking errors} +% This section lists all errors that can occur when type checking is +% performed. +% \begin{description} +parser_e_resourcestring_only_sg=03152_E_Resourcestrings kunnen alleen statisch of globaal zijn. +% Resourcestring can not be declared local, only global or using the static +% directive. +parser_e_exit_with_argument_not__possible=03153_E_Exit met parameter is hier niet toegestaan +% an exit statement with an argument for the return value can't be used here, this +% can happen e.g. in \var{try..except} or \var{try..finally} blocks +parser_e_stored_property_must_be_boolean=03154_E_De stored directive verwacht een boolean argument. +% If you specify a storage symbol in a property declaration, it must be of +% the type boolean +parser_e_ill_property_storage_sym=03155_E_Dit symbool is niet toegestaan achter het stored sleutelwoord. +% You can't use this type of symbol as storage specifier in property +% declaration. You can use only methods with the result type boolean, +% boolean class fields or boolean constants +parser_e_only_publishable_classes_can__be_published=03156_E_Alleen klassen gecompileerd in $M+ modus kunnen een published sectie hebben. +% In the published section of a class can be only class as fields used which +% are compiled in $M+ or which are derived from such a class. Normally +% such a class should be derived from TPersitent +parser_e_proc_directive_expected=03157_E_Proceduredirective verwacht. +% When declaring a procedure in a const block you used a ; after the +% procedure declaration after which a procedure directive must follow. +% Correct declarations are: +% \begin{verbatim} +% const +% p : procedure;stdcall=nil; +% p : procedure stdcall=nil; +% \end{verbatim} +parser_e_invalid_property_index_value=03158_E_De waarde voor een eigenschapindex moet een ordinale waarde zijn. +% The value you use to index a property must be of an ordinal type, for +% example an integer or enumerated type. +parser_e_procname_to_short_for_export=03159_E_Procedurenaam te kort om te exporteren. +% The length of the procedure/function name must be at least 2 characters +% long. This is because of a bug in dlltool which doesn't parse the .def +% file correct with a name of length 1. +parser_e_dlltool_unit_var_problem=03160_E_Kan geen DEFFILE item genereren voor globale variabelen. +parser_e_dlltool_unit_var_problem2=03161_E_Compileer zonder -WD optie +% \end{description} +# +# Type Checking +# +% \section{Type checking errors} +% This section lists all errors that can occur when type checking is +% performed. +% \begin{description} +parser_f_need_objfpc_or_delphi_mode=03162_F_U moet OBJFPC (-S2) of DELPHI (-Sd) mode gebruiken om deze code te compileren +% You need to use \{\$mode objfpc\} or \{\$mode delphi\} to compile this file. +% Or use the equivalent commandline switches -S2 or -Sd. +parser_e_no_export_with_index_for_target=03163_E_Kan niet exporteren met indexen kleiner dan $1 +% Exporting of functions or procedures with a specified index is not +% supported on this target. +parser_e_no_export_of_variables_for_target=03164_E_Exporteren van variabelen is niet ondersteund op $1 +% Exporting of variables is not supported on this target. +parser_e_improper_guid_syntax=03165_E_Ongeldige GUID aanduiding +parser_w_interface_mapping_notfound=03168_W_PGeen procedure genaamd "$1Ã" om "$2.$3" te implementeren gevonden +parser_e_interface_id_expected=03169_E_Interface aanduiding verwacht +% This happens when the compiler scans a \var{class} declaration that contains +% \var{interface} function name mapping code like this: +% \begin{verbatim} +% type +% TMyObject = class(TObject, IDispatch) +% function IUnknown.QueryInterface=MyQueryInterface; +% .... +% \end{verbatim} +% and the \var{interface} before the dot not listed in the inheritance list. +parser_e_type_cant_be_used_in_array_index=03170_E_Type "$1" kan niet als array index type gebruikt worden +% Types like \var{qword} or \var{int64} aren't allowed as array index type +parser_e_no_con_des_in_interfaces=03171_E_Constructors and destructors zijn niet toegestaan in interfaces +% Constructor and destructor declarations aren't allowed in interface +% In the most cases the method \var{QueryInterface} of \var{IUnknown} can +% be used to create a new interface. +parser_e_no_access_specifier_in_interfaces=03172_E_Toegangsmethoden kunnen niet gebruikt worden in interfaces +% The access specifiers \var{public}, \var{private}, \var{protected} and +% \var{pusblished} can't be used in interfaces because all methods +% of an interfaces must be public. +parser_e_no_vars_in_interfaces=03173_E_Een interface definitie kan geen velden bevatten +% Declarations of fields aren't allowed in interfaces. An interface +% can contain only methods +parser_e_no_local_proc_external=03174_E_Can lokale procedure niet als EXTERNAL definieren +% Declaring local procedures as external is not possible. Local procedures +% get hidden parameters that will make the chance of errors very high +parser_w_skipped_fields_before=03175_W_Sommige velden voor "$1Ã" zijn niet geinitialiseerd +% In Delphi mode, not all fields of a typed constant record have to be +% initialized, but the compiler warns you when it detects such situations. +parser_e_skipped_fields_before=03176_E_Sommige velden voor "$1" zijn niet geinitialiseerd +% In all syntax modes but Delphi mode, you can't leave some fields uninitialized +% in the middle of a typed constant record +parser_w_skipped_fields_after=03177_W_Sommige velden na "$1" zijn niet geinitialiseerd +% You can leave some fields at the end of a type constant record uninitialized +% (the compiler will initialize them to zero automatically). This may be the cause +% of subtle problems. +parser_e_varargs_need_cdecl_and_external=03178_E_VARARGS aanduiding zonder CDECL of EXTERNAL +% The varargs directive can only be used with procedures or functions +% that are declared with \var{cdecl} and \var{external} directives. The varargs directive +% is only meant to provide a compatible interface to C functions like printf. +parser_e_self_call_by_value=03179_E_SELF moet een normale waarde parameter zijn +% You can't declare self as a const or var parameter, it must always be +% a call-by-value parameter +parser_e_interface_has_no_guid=03180_E_Interface "$1" heeft geen interface definitie +% When you want to assign an interface to a constant, then the interface +% must have a GUID value set. +parser_e_illegal_field_or_method=03181_E_Ongekend klasse-veld of methode aanduiding "$1Ã" +% Properties must refer to a field or method in the same class. +parser_w_proc_overriding_calling=03182_W_Aanroep-modus "$1Ã" vervangen door "$2" +% There are two directives in the procedure declaration that specify a calling +% convention. Only the last directive will be used +parser_e_no_procvarobj_const=03183_E_Getypeerde constanten van type "procedure of object" kunnen alleen met NIL geinitialiseerd worden +% You can't assign the address of a method to a typed constant which has a +% 'procedure of object' type, because such a constant requires two addresses: +% that of the method (which is known at compile time) and that of the object or +% class instance it operates on (which can not be known at compile time). +parser_e_default_value_only_one_para=03184_E_De default aanduiding kan maar bij 1 parameter horen. +parser_e_default_value_expected_for_para=03185_E_Default parameter vereist voor "$1" +parser_w_unsupported_feature=03186_W_Gebruik van niet-ondersteunde mogelijkheden +% You're trying to force the compiler into doing something it cannot do yet. +parser_h_c_arrays_are_references=03187_H_C arrays worden via referentie doorgegeven +% Any array passed to a C functions is passed +% by a pointer (i.e. by reference). +parser_e_C_array_of_const_must_be_last=03188_E_"C array of const" moet het laatste argument zijn +% You can not add any other argument after an \var{array of const} for +% \var{cdecl} functions, as the size pushed on stack for this argument is +% not known. +parser_h_type_redef=03189_H_Type "$1Ã" herdefinitie +% This is an indicator that a previously declared type is +% being redefined as something else. This may, or may not +% be, a cause for errors. +parser_w_cdecl_has_no_high=03190_W_CDECL functies hebben geen HIGH parameter +% Functions declared with cdecl modifier do not pass an extra implicit parameter. +parser_w_cdecl_no_openstring=03191_W_CDECL functies ondersteunen geen open strings +% Openstring is not supported for cdecl'ared functions. +parser_e_initialized_not_for_threadvar=03192_E_Kan THREADVAR variabelen niet initialiseren +% Variables declared as threadvar can not be initialized with a default value. +% The variables will always be filled with zero at the start of a new thread. +parser_e_msg_only_for_classes=03193_E_de MESSAGE aanduiding is alleen toegestaan in classes +% The message directive is only supported for Class types. +parser_e_procedure_or_function_expected=03194_E_Procedure of functie verwacht +% A class method can only be specified for procedures and functions. +parser_e_illegal_calling_convention=03195_W_Aanroep-specificatie genegeerd: "$1" +% Some calling conventions are supported only by certain CPUs. I.e. most non-i386 ports support +% only the standard ABI calling convention of the CPU. +parser_e_no_object_reintroduce=03196_E_REINTRODUCE kan niet in objecten worden gebruikt +% \var{reintroduce} is not supported for objects. +parser_e_paraloc_only_one_para=03197_E_Elk argument moet zijn eigen locatie hebben +% If locations for arguments are specified explicitly as it is required by +% some syscall conventions, each argument must have it's only location, things +% like \var{procedure p(i,j : longint 'r1');} aren't allowed +parser_e_paraloc_all_paras=03198_E_Elk argument moet een expliciete locatie hebben +% If one argument has an explicit argument location, all arguments of a procedure +% must have one. +parser_e_illegal_explicit_paraloc=03199_E_Ongekende argument locatie +% The location specified for an argument isn't recognized by the compiler +parser_e_32bitint_or_pointer_variable_expected=03200_E_32-bit integer of pointer variabele verwacht +% The libbase for MorphOS/AmigaOS can be give only as \var{longint}, \var{dword} or any pointer variable. +parser_e_goto_outside_proc=03201_E_GOTO opdrachten zijn niet toegestaan tussen verschillende procedures +% It isn't allowed to use the \var{goto} statements referencing labels outside the +% current procedure. The following example shows the problem: +% \begin{verbatim} +% ... +% procedure p1; +% label +% l1; +% +% procedure p2; +% begin +% goto l1; // This goto ISN'T allowed +% end; +% +% begin +% p2 +% l1: +% end; +% ... +% +% \end{verbatim} +parser_f_too_complex_proc=03202_F_Procedure te moeilijk, te veel registers vereist +% Your procedure body is too long for the compiler. You should split the +% procedure into multiple smaller procedures. +parser_e_illegal_expression=03203_E_Ongeldige uitdrukking +% This can occur under many circumstances. Mostly when trying to evaluate +% constant expressions. +parser_e_invalid_integer=03204_E_Ongeldige integer uitdrukking +% You made an expression which isn't an integer, and the compiler expects the +% result to be an integer. +parser_e_invalid_qualifier=03205_E_Ongeldige aanduiding +% One of the following is happening : +% \begin{itemize} +% \item You're trying to access a field of a variable that is not a record. +% \item You're indexing a variable that is not an array. +% \item You're dereferencing a variable that is not a pointer. +% \end{itemize} +parser_e_upper_lower_than_lower=03206_E_Bovengrens kleiner dan ondergrens +% You are declaring a subrange, and the lower limit is higher than the high +% limit of the range. +parser_e_macpas_exit_wrong_param=03207_E_Exit parameter moet de naam zijn van de procedure waarin het gebruikt wordt +% Non local exit is not allowed. This error occur only in mode MacPas. +parser_e_illegal_assignment_to_count_var=03208_E_Ongeldige toekenning aan lus-variabele "$1" +% The type of a \var{for} loop variable must be an ordinal type. +% Loop variables cannot be reals or strings. +parser_e_no_local_var_external=03209_E_Kan een locale variabele niet als EXTERNAL aanduiden +% Declaring local variables as external is not allowed. Only global variables can reference +% to external variables. +parser_e_proc_already_external=03210_E_De procedure is reeds als EXTERNAL aangeduid +% The procedure is already declared with the EXTERNAL directive in an interface or +% forward declaration. +parser_w_implicit_uses_of_variants_unit=03211_W_Impliciet gebruik van de VARIANTS unit +% The Variant type is used in the unit without any used unit using the Variants unit. The +% compiler has implicitly added the Variants unit to the uses list. To remove this warning +% the Variants unit needs to be added to the uses statement. +parser_e_no_static_method_in_interfaces=03212_E_Class en statische methoden kunnen niet gebruikt worden in interfaces +% The specifier \var{class} and directive \var{static} can't be used in interfaces +% because all methods of an interfaces must be public. +parser_e_arithmetic_operation_overflow=03213_E_Overflow in wiskundige berekening +% An operation on two integers values produced an overflow +parser_e_protected_or_private_expected=03214_E_Protected of Private verwacht +% \var{strict} can be only used together with \var{protected} or \var{private}. +% \end{description} +# +# Type Checking +# +# 04049 is the last used one +# +% \section{Type checking errors} +% This section lists all errors that can occur when type checking is +% performed. +% \begin{description} +type_e_mismatch=04000_E_Typen stemmen niet overeen +% This can happen in many cases: +% \begin{itemize} +% \item The variable you're assigning to is of a different type than the +% expression in the assignment. +% \item You are calling a function or procedure with parameters that are +% incompatible with the parameters in the function or procedure definition. +% \end{itemize} +type_e_incompatible_types=04001_E_Incompatibele typen: kreeg $1, verwachtte $2 +% There is no conversion possible between the two types +% Another possiblity is that they are declared in different +% declarations: +% \begin{verbatim} +% Var +% A1 : Array[1..10] Of Integer; +% A2 : Array[1..10] Of Integer; +% +% Begin +% A1:=A2; { This statement gives also this error, it +% is due the strict type checking of pascal } +% End. +% \end{verbatim} +type_e_not_equal_types=04002_E_Typen komen niet overeen $1 en $2 +% The types are not equal +type_e_type_id_expected=04003_E_Typesymbool verwacht +% The identifier is not a type, or you forgot to supply a type identifier. +type_e_variable_id_expected=04004_E_Variabelesymbool verwacht +% This happens when you pass a constant to a \var{Inc} var or \var{Dec} +% procedure. You can only pass variables as arguments to these functions. +type_e_integer_expr_expected=04005_E_Gehele uitdrukking verwacht, $1 gekregen +% The compiler expects an expression of type integer, but gets a different +% type. +type_e_boolean_expr_expected=04006_E_Boolean waarde verwacht, kreeg echter "$1" +% The expression must be a boolean type, it should be return true or +% false. +type_e_ordinal_expr_expected=04007_E_Ordinale expressie verwacht +% The expression must be of ordinal type, i.e., maximum a \var{Longint}. +% This happens, for instance, when you specify a second argument +% to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value. +type_e_pointer_type_expected=04008_E_Pointer type verwacht, "$1" gekregen +% The variable or expression isn't of the type \var{pointer}. This +% happens when you pass a variable that isn't a pointer to \var{New} +% or \var{Dispose}. +type_e_class_type_expected=04009_E_Klasse type verwacht, "$1" gekregen +% The variable of expression isn't of the type \var{class}. This happens +% typically when +% \begin{enumerate} +% \item The parent class in a class declaration isn't a class. +% \item An exception handler (\var{On}) contains a type identifier that +% isn't a class. +% \end{enumerate} +type_e_cant_eval_constant_expr=04011_E_Kan constante expressie niet evalueren +% No longer in use. +type_e_set_element_are_not_comp=04012_E_Elementen van set zijn niet compatible +% You are trying to make an operation on two sets, when the set element types +% are not the same. The base type of a set must be the same when taking the +% union +type_e_set_operation_unknown=04013_E_Bewerking niet ondersteund voor sets +% several binary operations are not defined for sets +% like div mod ** (also >= <= for now) +type_w_convert_real_2_comp=04014_W_Typeconversie van vlottende-komma type naar COMP, wat een integer type is. +% An implicit type conversion from a real type to a \var{comp} is +% encountered. Since \var{Comp} is a 64 bit integer type, this may indicate +% an error. +type_h_use_div_for_int=04015_H_Gebruik DIV voor gehele getallen om geheel resultaat te krijgen +% When hints are on, then an integer division with the '/' operator will +% procuce this message, because the result will then be of type real +type_e_strict_var_string_violation=04016_E_String typen stemmen niet overeen wegens de $V+ modus +% When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter +% should be of the exact same type as the declared parameter of the procedure. +type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_SUCC of PRED op enumeratietypen met toekenningen zijn niet mogelijk +% When you declared an enumeration type which has assignments in it, as in C, +% like in the following: +% \begin{verbatim} +% Tenum = (a,b,e:=5); +% \end{verbatim} +% you cannot use the \var{Succ} or \var{Pred} functions on them. +type_e_cant_read_write_type=04018_E_Kan dit type variabelen niet lezen of schrijven +% You are trying to \var{read} or \var{write} a variable from or to a +% file of type text, which doesn't support that. Only integer types, +% booleans, reals, pchars and strings can be read from/written to a text file. +type_e_no_readln_writeln_for_typed_file=04019_E_Kan geen readln of writeln op getypeerde bestanden doen. +% \var{readln} and \var{writeln} are only allowed for text files. +type_e_no_read_write_for_untyped_file=04020_E_Kan geen read of write doen op ongetypeerde bestanden. +% \var{read} and \var{write} are only allowed for text or typed files. +type_e_typeconflict_in_set=04021_E_Typeconflict tussen setelementen. +% There is at least one set element which is of the wrong type, i.e. not of +% the set type. +type_w_maybe_wrong_hi_lo=04022_W_lo/hi(longint/dword) geeft hoog/laag (ipv byte) woord terug. +% \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword} +% which returns the lower/upper word of the argument. TP always uses +% a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the +% bits 8..15 for \var{hi}. If you want the TP behavior you have +% to type case the argument to \var{word/integer} +type_e_integer_or_real_expr_expected=04023_E_Integer of vlottende-komma uitdrukking verwacht +% The first argument to \var{str} must a real or integer type. +type_e_wrong_type_in_array_constructor=04024_E_Verkeerd type "$1" in array constructor +% You are trying to use a type in an array constructor which is not +% allowed. +type_e_wrong_parameter_type=04025_E_Incompatibel type voor argument #$1: kreeg $2, verwachtte $3 +% You are trying to pass an invalid type for the specified parameter. +type_e_no_method_and_procedure_not_compatible=04026_E_Methode (variabele) en Procedure (variable) zijn niet compatible +% You can't assign a method to a procedure variable or a procedure to a +% method pointer. +type_e_wrong_math_argument=04027_E_Ongeldige constante opgegeven aan interne wiskundige functie +% The constant argument passed to a ln or sqrt function is out of +% the definition range of these functions. +type_e_no_addr_of_constant=04028_E_Een constante heeft geen adres +% It's not possible to get the address of a constant, because they +% aren't stored in memory, you can try making it a typed constant. +% \end{description} +# +# Symtable +# +% \section{Symbol handling} +% This section lists all the messages that concern the handling of symbols. +% This means all things that have to do with procedure and variable names. +% \begin{description} +type_e_argument_cant_be_assigned=04029_E_Kan geen waarde toekennen aan argument +% Only expressions which can be on the left side of an +% assignment can be passed as call by reference argument +% Remark: Properties can be only +% used on the left side of an assignment, but they can't be used as arguments +type_e_cannot_local_proc_to_procvar=04030_E_Kan geen lokale procedure toekennen aan procedure variabele +% It's not allowed to assign a local procedure/function to a +% procedure variable, because the calling of local procedure/function is +% different. You can only assign local procedure/function to a void pointer. +type_e_no_assign_to_addr=04031_E_Kan geen waarde toekennen aan een adres +% It's not allowed to assign a value to an address of a variable,constant, +% procedure or function. You can try compiling with -So if the identifier +% is a procedure variable. +type_e_no_assign_to_const=04032_E_Kan geen waarde toekennen aan constante +% It's not allowed to assign a value to a variable which is declared +% as a const. This is normally a parameter declared as const, to allow +% changing make the parameter value or var. +% \end{description} +# +# Symtable +# +% \section{Symbol handling} +% This section lists all the messages that concern the handling of symbols. +% This means all things that have to do with procedure and variable names. +% \begin{description} +type_e_array_required=04033_E_ARRAY type verwacht +% If you are accessing a variable using an index '[<x>]' then +% the type must be an array. In FPC mode also a pointer is allowed. +type_e_interface_type_expected=04034_E_Interface type verwacht, maar kreeg "$1" +type_w_mixed_signed_unsigned=04035_W_Mengen van mogelijk negatieve uitdrukkingen en longwords geeft een 64-bits resultaat +% If you divide (or calculate the modulus of) a signed expression by a longword (or vice versa), +% or if you have overflow and/or range checking turned on and use an arithmetic +% expression (+, -, *, div, mod) in which both signed numbers and longwords appear, +% then everything has to be evaluated in 64bit which is slower than normal +% 32bit arithmetic. You can avoid this by typecasting one operand so it +% matches the resulttype of the other one. +type_w_mixed_signed_unsigned2=04036_W_Mengen van mogelijk negatieve uitdrukkingen en cardinals kan tot range check fouten leiden +% If you use a binary operator (and, or, xor) and one of +% the operands is a longword while the other one is a signed expression, then, +% if range checking is turned on, you may get a range check error because in +% such a case both operands are converted to longword before the operation is +% carried out. You can avoid this by typecasting one operand so it +% matches the resulttype of the other one. +type_e_typecast_wrong_size_for_assignment=04037_E_Typecast heeft een verschillende grootte ($1 -> $2) in toekenning +% Type casting to a type with a different size is not allowed when the variable is +% used for assigning. +type_e_array_index_enums_with_assign_not_possible=04038_E_enumeratie typen met vaste waarden kunnen niet als array index gebruikt worden +% When you declared an enumeration type which has assignments in it, as in C, +% like in the following: +% \begin{verbatim} +% Tenum = (a,b,e:=5); +% \end{verbatim} +% you cannot use it as index of an array. +type_e_classes_not_related=04039_E_Klasse of object types "$1Ã" en "$2" zijn niet verwant +% There is a typecast from one class or object to another while the class/object +% are not related. This will probably lead to errors +type_w_classes_not_related=04040_W_Klasse types "$1" en "$2" zijn niet verwant +% There is a typecast from one class or object to another while the class/object +% are not related. This will probably lead to errors +type_e_class_or_interface_type_expected=04041_E_Klasse of interface type verwacht, maar kreeg Ã"$1Ã" +type_e_type_is_not_completly_defined=04042_E_Type "$1Ã" is niet volledig gedefinieerd +type_w_string_too_long=04043_W_String constante heeft meer karakters dan de lengte van een shortstring +% The size of the constant string, which is assigned to a shortstring, +% is longer than the maximum size of the shortstring +type_w_signed_unsigned_always_false=04044_W_De vergelijking is steeds onwaar omwille van de interval waarden +% There is a comparison between an unsigned value and a signed constant which is +% less than zero. Because of type promotion, the statement will always evaluate to +% false. Exlicitly typecast the constant to the correct range to avoid this problem. +type_w_signed_unsigned_always_true=04045_W_e vergelijking is steeds waar omwille van de interval waarden +% There is a comparison between an unsigned value and a signed constant which is +% less than zero. Because of type promotion, the statement will always evaluate to +% true. Exlicitly typecast the constant to the correct range to avoid this problem. +type_w_instance_with_abstract=04046_W_Constructie van een klasse "$1" met abstracte methoden +% An instance of a class is created which contains non-implemented abstract +% methods. This will probably lead to a runtime error 211 in the code if that +% routine is ever called. All abstract methods should be overriden. +type_h_in_range_check=04047_H_De linker operand van de IN operator moet de grootte van een byte hebben +% The left operand of the \var{in} operator is not an ordinal or enumeration which fits +% within 8-bits, this may lead to range check errors. The \var{in} operator +% currently only supports a left operand which fits within a byte. In the case of +% enumerations, the size of an element of an enumeration can be controlled with +% the \var{\{\$PACKENUM\}} or \var{\{\$Zn\}} switches. +type_w_smaller_possible_range_check=04048_W_Grootte-fout voor type, mogelijk verlies van gegevens/interval-check fout +% There is an assignment to a smaller type than the source type. This means that +% this may cause a range-check error, or may lead to possible loss of data. +type_h_smaller_possible_range_check=04049_H_Grootte-fout voor type, mogelijk verlies van gegevens/interval-check fout +% There is an assignment to a smaller type than the source type. This means that +% this may cause a range-check error, or may lead to possible loss of data. +type_e_cant_take_address_of_abstract_method=04050_E_Het adres van een abstracte methode kan niet opgevraagd worden +% An abstract method has no body, so the address of an abstract method can't be taken. +type_e_operator_not_allowed=04051_E_De operator kan niet gebruikt worden op dit type operand +% You are trying an operator that is not available for the type of the +% operands +type_e_constant_expr_expected=04052_E_Constante uitdrukking verwacht +% The compiler expects an constant expression, but gets a variable expression. +type_e_operator_not_supported_for_types=04053_E_Operatie "$1" niet ondersteund voor types "$2" en "$3" +% The operation is not allowed for the supplied types +type_e_illegal_type_conversion=04054_E_Ongeldige type-conversie: "$1" naar "$2" +% When doing a type-cast, you must take care that the sizes of the variable and +% the destination type are the same. +type_h_pointer_to_longint_conv_not_portable=04055_H_Conversies tussen ordinalen en pointers is niet overzetbaar naar andere platformen +% If you typecast a pointer to a longint (or vice-versa), this code will not compile +% on a machine using 64-bit for pointer storage. +type_w_pointer_to_longint_conv_not_portable=04056_W_Conversies tussen ordinalen en pointers is niet overzetbaar naar andere platformen +% If you typecast a pointer to a ordinal type of a different size (or vice-versa), this can +% cause problems. This is a warning to help finding the 32bit specific code where cardinal/longint is used +% to typecast pointers to ordinals. A solution is to use the ptrint/ptruint types instead. +type_e_cant_choose_overload_function=04057_E_Kan niet beslissen welke overladen functie te kiezen +% You're calling overloaded functions with a parameter that doesn't correspond +% to any of the declared function parameter lists. e.g. when you have declared +% a function with parameters \var{word} and \var{longint}, and then you call +% it with a parameter which is of type \var{integer}. +type_e_illegal_count_var=04058_E_Ongeldige lus variabele +% The type of a \var{for} loop variable must be an ordinal type. +% Loop variables cannot be reals or strings. +% \end{description} +# +# Symtable +# +# 05055 is the last used one +# +% \section{Symbol handling} +% This section lists all the messages that concern the handling of symbols. +% This means all things that have to do with procedure and variable names. +% \begin{description} +sym_e_id_not_found=05000_E_Symbool niet gevonden $1 +% The compiler doesn't know this symbol. Usually happens when you misspel +% the name of a variable or procedure, or when you forgot to declare a +% variable. +sym_f_internal_error_in_symtablestack=05001_F_Interne fout in SymTableStack() +% An internal error occurred in the compiler; If you encounter such an error, +% please contact the developers and try to provide an exact description of +% the circumstances in which the error occurs. +sym_e_duplicate_id=05002_E_Dubbel symbool $1 +% The identifier was already declared in the current scope. +sym_h_duplicate_id_where=05003_H_Symbool reeds gedefinieerd in $1 op lijn $2 +% The identifier was already declared in a previous scope. +sym_e_unknown_id=05004_E_Onbekende symbool $1 +% The identifier encountered hasn't been declared, or is used outside the +% scope where it's defined. +sym_e_forward_not_resolved=05005_E_Voorwaartse declaratie niet opgelost $1 +% This can happen in two cases: +% \begin{itemize} +% \item This happens when you declare a function (in the \var{interface} part, or +% with a \var{forward} directive, but do not implement it. +% \item You reference a type which isn't declared in the current \var{type} +% block. +% \end{itemize} +sym_e_error_in_type_def=05007_E_Fout in type definitie +% There is an error in your definition of a new array type: +% \item One of the range delimiters in an array declaration is erroneous. +% For example, \var{Array [1..1.25]} will trigger this error. +sym_e_forward_type_not_resolved=05009_E_Forward declaratie niet opgelost $1 +% The compiler encountered an unknown type. +sym_e_only_static_in_static=05010_E_Alleen statische variabelen kunnen gebruikt worden in statische methoden +% A static method of an object can only access static variables. +sym_f_type_must_be_rec_or_class=05012_F_Record- of klassetype verwacht +% The variable or expression isn't of the type \var{record} or \var{class}. +sym_e_no_instance_of_abstract_object=05013_E_U kunt geen vertegenwoordiger van een klasse met abstracte methoden instantieren +% You are trying to generate an instance of a class which has an abstract +% method that wasn't overridden. +sym_w_label_not_defined=05014_W_Label niet gedefineerd $1 +% A label was declared, but not defined. +sym_e_label_used_and_not_defined=05015_E_Label "$1" gebruikt maar niet gedefinieerd +% A label was declared and used, but not defined. +sym_e_ill_label_decl=05016_E_Label foutief gedefineerd +% This error should never happen; it occurs if a label is defined outside a +% procedure or function. +sym_e_goto_and_label_not_supported=05017_E_GOTO en LABEL zijn afgezet (gebruik -Sg) +% You must compile a program which has \var{label}s and \var{goto} statements +% with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't +% supported. +sym_e_label_not_found=05018_E_Label niet gevonden +% A \var{goto label} was encountered, but the label isn't declared. +sym_e_id_is_no_label_id=05019_E_Symbool is geen label +% The identifier specified after the \var{goto} isn't of type label. +sym_e_label_already_defined=05020_E_Label is al gedefineerd +% You are defining a label twice. You can define a label only once. +sym_e_ill_type_decl_set=05021_E_Type declaratie van set elementen is foutief +% The declaration of a set contains an invalid type definition. +sym_e_class_forward_not_resolved=05022_E_Voorwaartse definitie van klasse niet opgelost $1 +% You declared a class, but you didn't implement it. +sym_n_unit_not_used=05023_H_Unit $1 wordt niet gebruikt in $2 +% The unit referenced in the \var{uses} clause is not used. +sym_h_para_identifier_not_used=05024_H_Parameter niet gebruikt $1 +% This is a warning. The identifier was declared (locally or globally) but +% wasn't used (locally or globally). +sym_n_local_identifier_not_used=05025_N_Lokale variabele niet gebruikt $1 +% You have declared, but not used a variable in a procedure or function +% implementation. +sym_h_para_identifier_only_set=05026_H_Waarde parameter $1 is gedeclareerd maar niet gebruikt. +% This is a warning. The identifier was declared (locally or globally) +% set but not used (locally or globally). +sym_n_local_identifier_only_set=05027_N_Lokale variabele $1 gedeclareerd maar niet gebruikt. +% The variable in a procedure or function +% implementation is declared, set but never used. +sym_h_local_symbol_not_used=05028_H_Lokaal $1 $2 is niet gebruikt +% A local symbol is never used. +sym_n_private_identifier_not_used=05029_N_Privaat veld $1.$2 wordt niet gebruikt +sym_n_private_identifier_only_set=05030_N_Privaat veld $1.$2 gedeclareerd maar niet gebruikt. +sym_n_private_method_not_used=05031_N_Private methode $1.$2 wordt nooit gebruikt. + + +sym_e_set_expected=05032_E_Set type verwacht +% The variable or expression isn't of type \var{set}. This happens in an +% \var{in} statement. +sym_w_function_result_not_set=05033_W_Resultaat van functie lijkt niet te zijn toegekend +% You can get this warning if the compiler thinks that a function return +% value is not set. This will not be displayed for assembler procedures, +% or procedures that contain assembler blocks. +sym_w_wrong_C_pack=05034_W_Type $1 is not aligned correctly in current record for C +% Arrays with sizes not multiples of 4 will be wrongly aligned +% for C structures. +sym_e_illegal_field=05035_E_Onbekend record lid $1 +% The field doesn't exist in the record definition. +sym_w_uninitialized_local_variable=05036_W_Lokale variabele "$1" lijkt niet geinitialiseerd +% This message is displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% was not initialized first (i.e. appeared in the left-hand side of an +% assigment) +sym_w_uninitialized_variable=05037_W_okale variabele "$1" lijkt niet geinitialiseerd +% This message is displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% was not initialized first (i.e. appeared in the left-hand side of an +% assigment) +sym_e_id_no_member=05038_E_Geen lid met de naam $1 +% When using the extended syntax of \var{new}, you must specify the constructor +% method of the class you are trying to create. The procedure you specified +% does not exist. +sym_h_param_list=05039_H_NDeclaratie "$1" gevonden +% You get this when you use the \var{-vh} switch. In case an overloaded +% procedure is not found, then all candidate overloaded procedures are +% listed, with their parameter lists. +sym_e_segment_too_large=05040_E_Data segment te groot (max. 2GB) +% You get this when you declare an array whose size exceeds the 2GB limit. +% \end{description} +# +# Codegenerator +# +% \section{Code generator messages} +% This section lists all messages that can be displayed if the code +% generator encounters an error condition. +% \begin{description} +sym_e_no_matching_implementation_found=05042_E_Geen overeenstemmende implementatie voor interface methode "$1" gevonden +% There was no matching method found which could implement the interface +% method. Check argument types and result type of the methods. +sym_w_deprecated_symbol=05043_W_Symbool "$1Ã" is afgeraden +% This means that a symbol (a variable, routine, etc...) which is +% declared as \var{deprecated} is used. Deprecated symbols may no longer +% be available in newer versions of the unit / library. Usage of this symbol +% should be avoided as much as possible. +sym_w_non_portable_symbol=05044_W_Symbool "$1" is niet overzetbaar naar andere platformen +% This means that a symbol (a variable, routine, etc...) which is +% declared as \var{platform} is used. This symbol's value, usage +% and availability is platform specific and should not be used +% if the source code must be portable. +sym_w_non_implemented_symbol=05055_W_Symbool "$1" is niet geimplementeerd +% This means that a symbol (a variable, routine, etc...) which is +% declared as \var{unimplemented} is used. This symbol is defined, +% but is not yet implemented on this specific platform. +sym_e_cant_create_unique_type=05056_E_Kan geen uniek type aanmaken van dit type +% Only simple types like ordinal, float and string types are supported when +% redefining a type with \var{type newtype = type oldtype;}. +sym_h_uninitialized_local_variable=05057_H_ Lokale variabele "$1" lijkt niet geinitialiseerd +% This message is displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% was not initialized first (i.e. appeared in the left-hand side of an +% assigment) +sym_h_uninitialized_variable=05058_H_Lokale variabele "$1" lijkt niet geinitialiseerd +% This message is displayed if the compiler thinks that a variable will +% be used (i.e. appears in the right-hand-side of an expression) when it +% was not initialized first (i.e. appeared in the left-hand side of an +% assigment) +% \end{description} +# +# Codegenerator +# +# 06040 is the last used one +# +% \section{Code generator messages} +% This section lists all messages that can be displayed if the code +% generator encounters an error condition. +% \begin{description} +cg_e_parasize_too_big=06009_E_Parameters gebruiken meer dan 64 kilobyte +% The I386 processor limits the parameter list to 65535 bytes (the \var{RET} +% instruction causes this) +cg_e_file_must_call_by_reference=06012_E_File variabelen moeten altijd var parameters zijn +% You cannot specify files as value parameters, i.e. they must always be +% declared \var{var} parameters. +cg_e_cant_use_far_pointer_there=06013_E_U kunt daar geen far pointer gebruiken +% Free Pascal doesn't support far pointers, so you cannot take the address of +% an expression which has a far reference as a result. The \var{mem} construct +% has a far reference as a result, so the following code will produce this +% error: +% \begin{verbatim} +% var p : pointer; +% ... +% p:=@mem[a000:000]; +% \end{verbatim} +cg_e_dont_call_exported_direct=06015_E_Procedures die als EXPORT gedeclareerd staan kunnen niet aangeroepen worden +% No longer in use. +cg_w_member_cd_call_from_method=06016_W_Mogelijke ongeldige aanroep van constructor of destructor +% No longer in use. +cg_n_inefficient_code=06017_N_Inefficiente code +% You construction seems dubious to the compiler. +cg_w_unreachable_code=06018_W_Deze code wordt nooit uitgevoerd +% You specified a loop which will never be executed. Example: +% \begin{verbatim} +% while false do +% begin +% {.. code ...} +% end; +% \end{verbatim} +cg_e_cant_call_abstract_method=06020_E_Abstracte methoden kunnen niet direct aangeroepen worden +% You cannot call an abstract method directy, instead you must call a +% overriding child method, because an abstract method isn't implemented. +cg_d_register_weight=06027_DL_Register $1 gewicht $2 $3 +% Debugging message. Shown when the compiler considers a variable for +% keeping in the registers. +cg_d_stackframe_omited=06029_DL_Stackframe wordt niet gemaakt +% Some procedure/functions do not need a complete stack-frame, so it is omitted. +% This message will be displayed when the {-vd} switch is used. +cg_e_unable_inline_object_methods=06031_E_Kan inline niet gebruiken voor object methoden +% You cannot have inlined object methods. +cg_e_unable_inline_procvar=06032_E_Kan inline niet gebruiken voor procvar aanroepen +% A procedure with a procedural variable call cannot be inlined. +cg_e_no_code_for_inline_stored=06033_E_Geen code voor inline procedure opgeslagen +% The compiler couldn't store code for the inline procedure. +cg_e_can_access_element_zero=06035_E_Element nul van een ansi/wide- of longstring is niet toegankelijk, gebruik (set)length. +% You should use \var{setlength} to set the length of an ansi/wide/longstring +% and \var{length} to get the length of such kinf of string +cg_e_cannot_call_cons_dest_inside_with=06037_E_Constructors of destructors kunnen niet aangeroepen worden binnen een 'with' clausule +% Inside a \var{With} clause you cannot call a constructor or destructor for the +% object you have in the \var{with} clause. +cg_e_cannot_call_message_direct=06038_E_Een message handler methode kan niet direct aangeroepen worden. +% A message method handler method can't be called directly if it contains an +% explicit self argument +% \end{description} +# EndOfTeX +# +# Assembler reader +# +cg_e_goto_inout_of_exception_block=06039_E_Sprong in of uit een exception blok +% It isn't allowed to jump in or outside of an exception block like \var{try..finally..end;}: +% \begin{verbatim} +% label 1; +% +% ... +% +% try +% if not(final) then +% goto 1; // this line will cause an error +% finally +% ... +% end; +% 1: +% ... +% \end{verbatim} +% \end{description} +cg_e_control_flow_outside_finally=06040_E_Control flow statements niet toegestaan in een finally blok +% It isn't allowed to use the control flow statements \var{break}, +% \var{continue} and \var{exit} +% inside a finally statement. The following example shows the problem: +% \begin{verbatim} +% ... +% try +% p; +% finally +% ... +% exit; // This exit ISN'T allowed +% end; +% ... +% +% \end{verbatim} +% If the procedure \var{p} raises an exception the finally block is +% executed. If the execution reaches the exit, it's unclear what to do: +% exiting the procedure or searching for another exception handler +# EndOfTeX +cg_w_parasize_too_big=06041_W_Grootte van de parameters is te groot voor bepaalde CPUs +% This indicates that you are declaring more than 64K of parameters, which +% might not be supported on other processor targets. +cg_w_localsize_too_big=06042_W_Grootte van lokale variabelen is te groot voor sommige CPUs +% This indicates that you are declaring more than 32K of local variables, which +% might not be supported on other processor targets. +cg_e_localsize_too_big=06043_E_Lokale variabelen te groot +% This indicates that you are declaring more than 32K of local variables, which +% is not supported by this processor. +cg_e_break_not_allowed=06044_E_BREAK niet toegelaten +% You're trying to use \var{break} outside a loop construction. +cg_e_continue_not_allowed=06045_E_CONTINUE niet toegelaten +% You're trying to use \var{continue} outside a loop construction. +cg_f_unknown_compilerproc=06046_F_Ongekende schakel-aanduiding "$1". Kijk na of u de correcte looptijd bibliotheek gebruikt +% The compiler expects that the runtime library contains some subrountines. If you see this error +% and you didn't mess with the runtime library, it's very likely that the runtime library +% you're using doesn't match the used compiler. If you changed the runtime library this error means +% that you removed a subroutine which the compiler needs for internal use. +% \end{description} +# EndOfTeX + +# +# Assembler reader +# +# 07097 is the last used one +# +asmr_d_start_reading=07000_DL_Begonnen met verwerken van $1 assembler +% This informs you that an assembler block is being parsed +asmr_d_finish_reading=07001_DL_Gedaan met verwerken van $1 assembler +% This informs you that an assembler block has finished. +asmr_e_none_label_contain_at=07002_E_Symbool dat geen label is bevat "@" +% A identifier which isn't a label can't contain a @. +asmr_e_building_record_offset=07004_E_Fout bij berekenen offset in record +% There has an error occured while building the offset of a record/object +% structure, this can happend when there is no field specified at all or +% an unknown field identifier is used. +asmr_e_offset_without_identifier=07005_E_OFFSET gebruikt zonder symbool +% You can only use OFFSET with an identifier. Other syntaxes aren't +% supported +asmr_e_type_without_identifier=07006_E_TYPE gebruikt zonder symbool +% You can only use TYPE with an identifier. Other syntaxes aren't +% supported +asmr_e_no_local_or_para_allowed=07007_E_Kan hier geen lokale variabele of parameter gebruiken +% You can't use a local variable or parameter here, mostly because the +% addressing of locals and parameters is done using the %ebp register so the +% address can't be get directly. +asmr_e_need_offset=07008_E_OFFSET moet hier gebruikt worden +% You need to use OFFSET <id> here to get the address of the identifier. +asmr_e_need_dollar=07009_E_Gebruik van $ is hier verplicht +% You need to use $<id> here to get the address of the identifier. +asmr_e_cant_have_multiple_relocatable_symbols=07010_E_Kan niet meerdere verplaatsbare symbolen gebruiken +% You can't have more than one relocatable symbol (variable/typed constant) +% in one argument. +asmr_e_only_add_relocatable_symbol=07011_E_Een verplaatsbaar symbool kan enkel toegevoegd worden +% Relocatable symbols (variable/typed constant) can't be used with other +% operators. Only addition is allowed. +asmr_e_invalid_constant_expression=07012_E_Ongeldige constante uitdrukking +% There is an error in the constant expression. +asmr_e_relocatable_symbol_not_allowed=07013_E_Verplaatsbaar symbool niet toegelaten +% You can't use a relocatable symbol (variable/typed constant) here. +asmr_e_invalid_reference_syntax=07014_E_Ongeldige geheugenlocatie schrijfwijze +% There is an error in the reference. +asmr_e_local_para_unreachable=07015_E_$1 niet bereikbaar vanuit deze code +% You can not read directly the value of local or para +% of a higher level in assembler code (except for +% local assembler code without parameter nor locals). +asmr_e_local_label_not_allowed_as_ref=07016_E_Lokale symbolen/labels niet toegestaan als referenties +% You can't use local symbols/labels as references +asmr_e_wrong_base_index=07017_E_Ongeldig gebruik van basis en index register +% There is an error with the base and index register +asmr_w_possible_object_field_bug=07018_W_Mogelijke fout in behandeling velden van object. +% Fields of objects or classes can be reached directly in normal or objfpc +% modes but TP and Delphi modes treat the field name as a simple offset. +asmr_e_wrong_scale_factor=07019_E_Ongeldige schaalfactor +% The scale factor given is wrong, only 1,2,4 and 8 are allowed +asmr_e_multiple_index=07020_E_Meervoudig indexregister gebruik +% You are trying to use more than one index register +asmr_e_invalid_operand_type=07021_E_Ongeldig operandus type +% The operand type doesn't match with the opcode used +asmr_e_invalid_string_as_opcode_operand=07022_E_Ongeldige tekenreeks als instructie operandus: $1 +% The string specified as operand is not correct with this opcode +asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE en @DATA worden niet ondersteund +% @CODE and @DATA are unsupported and are ignored. +asmr_e_null_label_ref_not_allowed=07024_E_Null label verwijzingen zijn niet toegelaten +asmr_e_expr_zero_divide=07025_E_Deling door nul +% There is a division by zero in a constant expression +asmr_e_expr_illegal=07026_E_Ongeldige uitdrukking +% There is an illegal expression in a constant expression +asmr_e_escape_seq_ignored=07027_E_Expliciete reeks genegeerd: $1 +% There is a C-styled string, but the escape sequence in the string +% is unknown, and is therefore ignored +asmr_e_invalid_symbol_ref=07028_E_Ongeldige symboolverwijzing +asmr_w_fwait_emu_prob=07029_W_Fwait kan emulatieproblemen met emu387 veroorzaken +asmr_w_fadd_to_faddp=07030_W_$1 zonder operand vertaald naar $1P +asmr_w_enter_not_supported_by_linux=07031_W_De ENTER instructie wordt niet ondersteund door de Linux kernel +% ENTER instruction can generate a stack page fault that is not +% caught correctly by the i386 Linux page handler. +asmr_w_calling_overload_func=07032_W_Een overroepen functie wordt aangeroepen vanuit assemblercode +% There is a call to an overloaded method in the assembler block, +% this might be the sign there is a problem +asmr_e_unsupported_symbol_type=07033_E_Niet ondersteund symbool type voor operandus +asmr_e_constant_out_of_bounds=07034_E_Constante waarde valt buiten bereik +asmr_e_error_converting_decimal=07035_E_Fout bij omzetten van decimaal getal $1 +% A constant decimal value does not have the correct syntax +asmr_e_error_converting_octal=07036_E_Fout bij omzetten van octaal getal $1 +% A constant octal value does not have the correct syntax +asmr_e_error_converting_binary=07037_E_Fout bij omzetten van binair getal $1 +% A constant binary value does not have the correct syntax +asmr_e_error_converting_hexadecimal=07038_E_Fout bij omzetten van hexadecimaal getal $1 +% A constant hexadecimal value does not have the correct syntax +asmr_h_direct_global_to_mangled=07039_H_$1 vertaald naar $2 +asmr_w_direct_global_is_overloaded_func=07040_W_$1 is geassocieerd met een overroepen functie +asmr_e_cannot_use_SELF_outside_a_method=07041_E_Kan SELF niet buiten een methode gebruiken +% There is a reference to the \var{self} symbol while it is not +% allowed. \var{self} can only be referenced inside methods +asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_Kan OLDEBP niet buiten een genestelde procedure gebruiken +% There is a reference to the \var{oldebp} symbol while it is not +% allowed. \var{oldebp} can only be referenced inside nested routines +asmr_e_void_function=07043_W_Functies met een ongedefinieerde teruggeefwaarde kunnen geen waarde teruggeven +% Trying to return a value while in a procedure. A procedure +% does not have any return value +asmr_e_SEG_not_supported=07044_E_SEG niet ondersteund +asmr_e_size_suffix_and_dest_dont_match=07045_E_Grootte-achtervoegsel en doel- of brongrootte komen niet overeen +% The register size and the opcode size suffix don't match. This is +% probably an error in the assembler statement +asmr_w_size_suffix_and_dest_dont_match=07046_W_Grootte-achtervoegsel en doel- of brongrootte komen niet overeen +% The register size and the opcode size suffix don't match. This is +% probably an error in the assembler statement +asmr_e_syntax_error=07047_E_Assembler taalfout +% There is an assembler syntax error +asmr_e_invalid_opcode_and_operand=07048_E_Ongeldige combinatie van instructie en operandi +% The opcode cannot be used with this type of operand +asmr_e_syn_operand=07049_E_Assembler taalfout in operandum +asmr_e_syn_constant=07050_E_Assembler taalfout in constante +asmr_e_invalid_string_expression=07051_E_Ongeldige String uitdrukking +asmr_w_const32bit_for_address=07052_W_ Constante met symbool $1 voor adres dat zich niet op een pointer bevindt +% A constant expression represents an address which does not fit +% into a pointer. The address is probably incorrect +asmr_e_unknown_opcode=07053_E_Ongekende opcode $1 +% This opcode is not known +asmr_e_invalid_or_missing_opcode=07054_E_Ongeldige of ontbrekende instructie +asmr_e_invalid_prefix_and_opcode=07055_E_Ongeldige combinatie van voorvoegsel en instructie: $1 +asmr_e_invalid_override_and_opcode=07056_E_Ongeldige combinatie van segment overroeping en instructie: $1 +asmr_e_too_many_operands=07057_E_Te veel operandi op een lijn +% There are too many operands for this opcode. Check your +% assembler syntax +asmr_w_near_ignored=07058_W_NEAR genegeerd +asmr_w_far_ignored=07059_W_FAR genegeerd +asmr_e_dup_local_sym=07060_E_Dubbel lokaal symbool $1 +asmr_e_unknown_local_sym=07061_E_Niet gedefinieerd lokaal symbool $1 +asmr_e_unknown_label_identifier=07062_E_Onbekende labelnaam $1 +asmr_e_invalid_register=07063_E_Ongeldige register naam +% There is an unknown register name used as operand. +asmr_e_invalid_fpu_register=07064_E_Ongeldig vlottende-komma registernaam +% There is an unknown register name used as operand. +asmr_w_modulo_not_supported=07066_W_Modulo wordt niet ondersteund +asmr_e_invalid_float_const=07067_E_Ongeldige vlottende-komma constante $1 +% The floating point constant declared in an assembler block is +% invalid. +asmr_e_invalid_float_expr=07068_E_Ongeldige vlottende-komma uitdrukking +% The floating point expression declared in an assembler block is +% invalid. +asmr_e_wrong_sym_type=07069_E_Verkeerd symbool type +asmr_e_cannot_index_relative_var=07070_E_Een lokale variabele of parameter kan niet geindedxeerd worden met een register +% Trying to index using a base register a symbol which is already relative +% to a register. This is not possible, and will probably lead to crashes. +asmr_e_invalid_seg_override=07071_E_Ongeldige segment overroeping +asmr_w_id_supposed_external=07072_W_Symbool $1 wordt verondersteld extern te zijn +% There is a reference to an undefined symbol. This will not result +% in an error, since the symbol might be external, but may cause +% problems at link time if the symbol is not defined anywhere. +asmr_e_string_not_allowed_as_const=07073_E_Strings zijn niet toegelaten als constante +% Character strings are not allowed as constants. +asmr_e_no_var_type_specified=07074_Geen type van de variabele gegeven +% The syntax expects a type idenfitifer after the dot, but +% none was found. +asmr_w_assembler_code_not_returned_to_text=07075_E_De assembler code stopt niet in een '.text' gedeelte +% There was a directive in the assembler block to change sections, +% but there is a missing return to the text section at the end +% of the assembler block. This might cause errors during link time. +asmr_e_not_directive_or_local_symbol=07076_E_Geen aanwijzing of lokaal symbool $1 +% This symbol is unknown. +asmr_w_using_defined_as_local=07077_E_Een gedfinieerde naam wordt gebruikt als assembler label + +# +# Assembler/binary writers +# +asmr_e_dollar_without_identifier=07078_E_Dollar teken gebruikt zonder identifier +% A constant expression has an identifier which does not start with +% the $ symbol. +asmr_w_32bit_const_for_address=07079_W_32bit constante aangemaakt voor adres +% A constant was used as an address. This is probably an error, +% since using absolute addresses will probably not work. +asmr_n_align_is_target_specific=07080_N_.align is doel specifiek, gebruik .balign of .p2align +% Using the .align directive is platform specific, and its meaning will vary +% from one platform to another. +asmr_e_cannot_access_field_directly_for_parameters=07081_E_Kan velden niet direct gebruiken voor parameters. +% You should load the parameter first into a register and then access the +% fields using that register. +asmr_e_cannot_access_object_field_directly=07082_E_Kan velden van objecten/klassen niet direct aanspreken +% You should load the self pointer first into a register and then access the +% fields using the register as base. By default the self pointer is available +% in the esi register on i386. +# +# Assembler/binary writers +# +asmr_e_unable_to_determine_reference_size=07083_E_Geen grootte aangegegeven en kan de grootte van de operanden niet bepalen +% You should specify explicitly a size for the reference, because +% the compiler is unable to determine what size (byte,word,dword,etc.) it +% should use for the reference. +asmr_e_cannot_use_RESULT_here=07084_E_Kan RESULT aanduiding niet gebruiken in deze functie +% Some functions which return complex types cannot use the \var{result} +% keyword. +asmr_w_adding_explicit_args_fXX=07086_W_"$1Ã" zonder operand vertaald naar "$1 %st,%st(1)" +asmr_w_adding_explicit_first_arg_fXX=07087_W_"$1 %st(n)" vertaald naar "$1 %st,%st(n)" +asmr_w_adding_explicit_second_arg_fXX=07088_W_"$1 %st(n)" vertaald naar "$1 %st(n),%st" +asmr_e_invalid_char_smaller=07089_E_Karakter < hier niet toegestaan +% The shift operator requires the << characters. Only one +% of those characters was found. +asmr_e_invalid_char_greater=07090_E_Karakter > hier niet toegestaan +% The shift operator requires the >> characters. Only one +% of those characters was found. +asmr_w_align_not_supported=07093_W_ALIGN niet ondersteund +asmr_e_no_inc_and_dec_together=07094_E_INC en DEC kunnen niet samengaan +% Trying to use an increment and a decrement within the same +% opcode on the 680x0. This is impossible. +asmr_e_invalid_reg_list_in_movem=07095_E_Ongeldige register lijst voor movem +% Trying to use the \var{movem} opcode with invalid registers +% to save or restore. +asmr_e_invalid_reg_list_for_opcode=07096_E_Ongeldige register lijst voor opcode +asmr_e_higher_cpu_mode_required=07097_E_hogere CPU mode vereist ($1) +% Trying to use an instruction which is not supported in the current +% cpu mode. Use a higher cpu generation to be able to use this +% opcode in your assembler block +asmr_w_unable_to_determine_reference_size_using_dword=07098_W_Grootte niet opgegeven en kan de grootte van de operanden niet bepalen. De standaard DWORD wordt gebruikt +% You should specify explicitly a size for the reference, because +% the compiler is unable to determine what size (byte,word,dword,etc.) it +% should use for the reference. This warning is only used in Delphi mode where +% it falls back to use DWORD as default. +asmr_e_illegal_shifterop_syntax=07099_E_Syntax fout bij het bepalen van een shift operand +% ARM only; ARM assembler supports a so called shifter operand. The used syntax isn't +% a valid shifter operand. Example for an operation with shifter operand: +% \begin{verbatim} +% asm +% orr r2,r2,r2,lsl #8 +% end; +% \end{verbatim} +# +# Assembler/binary writers +# +# 08018 is the last used one +# +asmw_f_too_many_asm_files=08000_F_Te veel assemblerbestanden +% With smartlinking enabled, there are too many assembler +% files generated. Disable smartlinking. +asmw_f_assembler_output_not_supported=08001_F_De geselecteerde assembler modus wordt hier niet ondersteund +asmw_f_comp_not_supported=08002_F_Het COMP type wordt hier niet ondersteund +asmw_f_direct_not_supported=08003_F_Directe assembler modus wordt niet ondersteund door de binaire assemblerschrijver +% Direct assembler mode is not supported for binary writers. +asmw_e_alloc_data_only_in_bss=08004_E_Ruimte voor gegevens reserveren mag enkel in een bss gedeelte +asmw_f_no_binary_writer_selected=08005_F_Binaire assemblerschrijver geselecteerd +asmw_e_opcode_not_in_table=08006_E_Asm: Opcode $1 not gevonden in interne tabel +asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 Ongeldige combinatie van instructie en operandi +asmw_e_16bit_not_supported=08008_E_Asm: 16 Bit geheugenlocaties worden niet ondersteund +asmw_e_invalid_effective_address=08009_E_Asm: Ongeldig direct adres +asmw_e_immediate_or_reference_expected=08010_E_Asm: Constante of geheugenadres verwacht +asmw_e_value_exceeds_bounds=08011_E_Asm: $1 waarde overschrijdt grenzen van $2 +asmw_e_short_jmp_out_of_range=08012_E_Asm: Korte spronginstructie gaat te ver $1 + +# +# Executing linker/assembler +# +asmw_e_undefined_label=08013_E_Asm: Ongedefinieerd label $1 + + +# +# Executing linker/assembler +# +# BeginOfTeX +% +% \section{Errors of assembling/linking stage} +% This section lists errors that occur when the compiler is processing the +% command line or handling the configuration files. +% \begin{description} +asmw_e_comp_not_supported=08014_E_Asm: COMP type niet ondersteund voor dit platfirl +asmw_e_extended_not_supported=08015_E_Asm: EXTENDED type niet ondersteund voor dit platform +asmw_e_duplicate_label=08016_E_Asm: Label dubbel gebruikt: $1 +asmw_e_redefined_label=08017_E_Asm: Label opnieuw gedefinieerd: $1 +asmw_e_first_defined_label=08018_E_Asm: eerste definitie hier +asmw_e_invalid_register=08019_E_Asm: ongeldig register $1 + +# +# Executing linker/assembler +# +# 09034 is the last used one +# +# BeginOfTeX +% +% \section{Errors of assembling/linking stage} +% This section lists errors that occur when the compiler is processing the +% command line or handling the configuration files. +% \begin{description} +exec_w_source_os_redefined=09000_W_Bronbesturingssysteem geherdefinieerd +exec_i_assembling_pipe=09001_I_Assembleren (pijp) van $1 +exec_d_cant_create_asmfile=09002_E_Kan geen assembler bestand $1 niet maken +% The mentioned file can't be create. Check if you've +% permission to create this file +exec_e_cant_create_objectfile=09003_E_Kan geen object bestand openen: $1 +% The mentioned file can't be create. Check if you've +% permission to create this file +exec_e_cant_create_archivefile=09004_E_kan geen archief bestand openen: $1 +% The mentioned file can't be create. Check if you've +% permission to create this file +exec_e_assembler_not_found=09005_E_Assembler $1 niet gevonden. Schakel over op externe assemblage +exec_t_using_assembler=09006_T_Gebruikte assembler: $1 +exec_e_error_while_assembling=09007_E_Fout bij het assembleren, exit code $1 +% There was an error while assembling the file using an external assembler. +% Consult the documentation of the assembler tool to find out more information +% on this error. +exec_e_cant_call_assembler=09008_E_Kan de assembler niet oproepen, fout $1. Schakel over op externe assemblage +exec_i_assembling=09009_I_Assembleren van $1 +exec_i_assembling_smart=09010_I_Assembleren slim-link $1 +exec_w_objfile_not_found=09011_W_Bestand $1 niet gevonden, linken kan foutlopen ! +% One of the object file is missing, and linking will probably fail. +% Check your paths. +exec_w_libfile_not_found=09012_W_Bibliotheek $1 niet gevonden, linken kan foutlopen ! +% One of the library file is missing, and linking will probably fail. +% Check your paths. +exec_e_error_while_linking=09013_E_Fout bij het linken +% Generic error while linking. +exec_e_cant_call_linker=09014_E_Kan de linker niet oproepen, schakel over op extern linken +exec_i_linking=09015_I_Linken van $1 +exec_e_util_not_found=09016_E_Gereedschap $1 niet gevonden, schakel over op extern linken +exec_t_using_util=09017_T_Gebruik tool $1 +exec_e_exe_not_supported=09018_E_Creatie van executable bestanden niet ondersteund. +exec_e_dll_not_supported=09019_E_Dynamische bibliotheken niet ondersteund +exec_i_closing_script=09020_I_Afsluiten batch $1 +exec_e_res_not_found=09021_E_Resource compiler niet gevonde, schakel over op externe modus +exec_i_compilingresource=09022_I_Compileer resource $1 +# +# Executable information +# +exec_t_unit_not_static_linkable_switch_to_smart=09023_T_Unit $1 kan niet statisch gelinkt worden. Schakel over op slim linken +exec_t_unit_not_smart_linkable_switch_to_static=09024_T_Unit $1 kan niet slim gelinkt worden. Schakel over op statisch linken +exec_t_unit_not_shared_linkable_switch_to_static=09025_T_Unit $1 kan niet gedeeld gelinkt worden, Schakel over op statisch linken +exec_e_unit_not_smart_or_static_linkable=09026_E_Unit $1 kan niet slim of statisch gelinkt worden +exec_e_unit_not_shared_or_static_linkable=09027_E_Unit $1 kan niet gedeeld of statisch gelinkt worden +exec_d_resbin_params=09028_D_Oproep resource compiler "$1" met "$2" als commando-lijn opties +%\end{description} +# EndOfTeX + +# +# Executable information +# +execinfo_f_cant_process_executable=09128_F_Kan applicatie niet nabehandelen $1 +execinfo_f_cant_open_executable=09129_F_Kan applicatie niet openen $1 +execinfo_x_codesize=09130_X_Grootte van de code: $1 bytes +execinfo_x_initdatasize=09131_X_Grootte van geinitialiseerde data: $1 bytes +execinfo_x_uninitdatasize=09132_X_Grootte van niet-geinitialiseerde data: $1 bytes +execinfo_x_stackreserve=09133_X_Gereserveerde stackruimte: $1 bytes +execinfo_x_stackcommit=09134_X_Toegewezen stackruimte: $1 bytes +# Unit loading +# +# BeginOfTeX +% \section{Unit loading messages.} +% This section lists all messages that can occur when the compiler is +% loading a unit from disk into memory. Many of these mesages are +% informational messages. +% \begin{description} +unit_t_unitsearch=10000_T_Unit zoeken: $1 +% When you use the \var{-vt}, the compiler tells you where it tries to find +% unit files. +unit_t_ppu_loading=10001_T_PPU Laden $1 +% When the \var{-vt} switch is used, the compiler tells you +% what units it loads. +unit_u_ppu_name=10002_U_PPU Naam: $1 +% When you use the \var{-vu} flag, the unit name is shown. +unit_u_ppu_flags=10003_U_PPU Vlaggen: $1 +% When you use the \var{-vu} flag, the unit flags are shown. +unit_u_ppu_crc=10004_U_PPU CRC: $1 +% When you use the \var{-vu} flag, the unit CRC check is shown. +unit_u_ppu_time=10005_U_PPU Tijd: $1 +% When you use the \var{-vu} flag, the unit time is shown. +unit_u_ppu_file_too_short=10006_U_PPU bestand te kort +% When you use the \var{-vu} flag, the unit time is shown. +unit_u_ppu_invalid_header=10007_U_PPU Ongeldige kop (geen PPU aan het begin) +% A unit file contains as the first three bytes the ascii codes of \var{PPU} +unit_u_ppu_invalid_version=10008_U_PPU Ongeldige versie $1 +% This unit file was compiled with a different version of the compiler, and +% cannot be read. +unit_u_ppu_invalid_processor=10009_U_PPU is gecompileerd voor een andere processor +% This unit file was compiled for a different processor type, and +% cannot be read +unit_u_ppu_invalid_target=10010_U_PPU is gecompileerd voor een ander doelsysteem +% This unit file was compiled for a different processor type, and +% cannot be read +unit_u_ppu_source=10011_U_PPU bron: $1 +% When you use the \var{-vu} flag, the unit CRC check is shown. +unit_u_ppu_write=10012_U_Schrijven van $1 +% When you specify the \var{-vu} switch, the compiler will tell you where it +% writes the unit file. +unit_f_ppu_cannot_write=10013_F_Kan PPU bestand niet schrijven +% An err +unit_f_ppu_read_error=10014_F_Lezen van PPU bestand +% Unexpected end of file +unit_f_ppu_read_unexpected_end=10015_F_Onverwacht einde van PPU-bestand +% This means that the unit file was corrupted, and contains invalid +% information. Recompilation will be necessary. +unit_f_ppu_invalid_entry=10016_F_Ongeldig PPU bestand post: $1 +% The unit the compiler is trying to read is corrupted, or generated with a +% newer version of the compiler. +unit_f_ppu_dbx_count_problem=10017_F_PPU Dbx aantal probleem +% There is an inconsistency in the debugging information of the unit. +unit_e_illegal_unit_name=10018_E_Ongeldige unitnaam: $1 +% The name of the unit doesn't match the file name. +unit_f_too_much_units=10019_F_Te veel units +% \fpc has a limit of 1024 units in a program. You can change this behavior +% by changing the \var{maxunits} constant in the \file{files.pas} file of the +% compiler, and recompiling the compiler. +unit_f_circular_unit_reference=10020_F_Uses statement veroorzaakt vicieuze cirkel tussen $1 en $2 +% Two units are using each other in the interface part. This is only allowed +% in the \var{implementation} part. At least one unit must contain the other one +% in the \var{implementation} section. +unit_f_cant_compile_unit=10021_F_Kan unit $1 niet compileren, geen broncode beschikbaar +% A unit was found that needs to be recompiled, but no sources are +% available. +unit_f_cant_find_ppu=10022_F_Kan unit $1 niet vinden +% You tried to use a unit of which the PPU file isn't found by the +% compiler. Check your config files for the unit pathes +unit_w_unit_name_error=10023_W_Unit $1 niet gevonden maar $2 bestaat +unit_f_unit_name_error=10024_F_Unit $1 gezocht maar $2 gevonden +% Dos truncation of 8 letters for unit PPU files +% may lead to problems when unit name is longer than 8 letters. +unit_w_switch_us_missed=10025_W_De systeemunit compileren vereist de -Us schakelaar +% When recompiling the system unit (it needs special treatment), the +% \var{-Us} must be specified. +unit_f_errors_in_unit=10026_F_Er waren fouten $1 bij het compileren van een module, compilatie gestopt. +% When the compiler encounters a fatal error or too many errors in a module +% then it stops with this message. +unit_u_load_unit=10027_U_Laden van $1 ($2) unit $3 +% When you use the \var{-vu} flag, which unit is loaded from which unit is +% shown. +unit_u_recompile_crc_change=10028_U_Hercompileer $1, checksum voor $2 veranderd +unit_u_recompile_source_found_alone=10029_U_herkompileer $1, alleen bron gevonden +% When you use the \var{-vu} flag, these messages tell you why the current +% unit is recompiled. +unit_u_recompile_staticlib_is_older=10030_U_Hercompileer unit, statische bibliotheek ouder dan ppu-bestand +% When you use the \var{-vu} flag, the compiler warns if the static library +% of the unit are older than the unit file itself. +unit_u_recompile_sharedlib_is_older=10031_U_Hercompileer unit, dynamische bibliotheek ouder dan ppu-bestand +% When you use the \var{-vu} flag, the compiler warns if the shared library +% of the unit are older than the unit file itself. +unit_u_recompile_obj_and_asm_older=10032_U_Hercompileer unit, object en asm zijn ouder dan ppu-bestand +% When you use the \var{-vu} flag, the compiler warns if the assembler of +% object file of the unit are older than the unit file itself. +unit_u_recompile_obj_older_than_asm=10033_U_Hercompileer unit, object is ouder dan assembler +% When you use the \var{-vu} flag, the compiler warns if the assembler +% file of the unit is older than the object file of the unit. +unit_u_parsing_interface=10034_U_Interface van $1 wordt geparsed +% When you use the \var{-vu} flag, the compiler warns that it starts +% parsing the interface part of the unit +unit_u_parsing_implementation=10035_U_Implementatie van $1 wordt geparsed +% When you use the \var{-vu} flag, the compiler warns that it starts +% parsing the implementation part of the unit +unit_u_second_load_unit=10036_U_Tweede maal unit $1 laden +% When you use the \var{-vu} flag, the compiler warns that it starts +% recompiling a unit for the second time. This can happend with interdepend +% units. +unit_u_check_time=10037_U_PPU Controleren van bestand $1 tijd $2 +% When you use the \var{-vu} flag, the compiler show the filename and +% date and time of the file which a recompile depends on +% \end{description} +# EndOfTeX +# +# Options +# +unit_w_cant_compile_unit_with_changed_incfile=10040_W_Kan unit $1 niet hercompileren, maar vond gewijzigde include bestanden +% A unit was found to have modified include files, but +% some source files were not found, so recompilation is impossible. +unit_h_source_modified=10041_H_Bestand $1 is nieuwer dan release PPU bestand $2 +% A modified source file for a unit was found that was compiled with the +% release flag (-Ur). The unit will not implicitly be recompiled because +% this release flag is set. +unit_u_ppu_invalid_fpumode=10042_U_Er wordt een unit gebruikt die niet met de correcte FPU modus is gecompileerd +% Trying to compile code while using units which were not compiled with +% the same floating point format mode. Either all code should be compiled +% with FPU emulation on, or with FPU emulation off. +unit_u_loading_interface_units=10043_U_Laden van interface units voor unit $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% loading the units defined in the interface part of the unit. +unit_u_loading_implementation_units=10044_U_Laden van implementatie units voor unit $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% loading the units defined in the implementation part of the unit. +unit_u_interface_crc_changed=10045_U_Interface CRC voor unit $1 is gewijzigd +% When you use the \var{-vu} flag, the compiler warns that it the +% CRC calculated for the interface has been changed after the implementation +% has been parsed. +unit_u_implementation_crc_changed=10046_U_Implementatie CRC voor unit $1 is gewijzigd +% When you use the \var{-vu} flag, the compiler warns that it the +% CRC calculated has been changed after the implementation +% has been parsed. +unit_u_finished_compiling=10047_U_Klaar met compileren van unit Â$1 +% When you use the \var{-vu} flag, the compiler warns that it +% has finished compiling the unit. +unit_u_add_depend_to=10048_U_Afhankelijkheid van $1 toegevoegd aan $2 +% When you use the \var{-vu} flag, the compiler warns that it +% has added a dependency between the two units. +unit_u_no_reload_is_caller=10049_U_Niet herladen, oproeper is: $1 +% When you use the \var{-vu} flag, the compiler warns that it +% has will not reload the unit because it is the unit that wants +% to load this unit +unit_u_no_reload_in_second_compile=10050_U_Niet herladen, reads in tweede compilatie: $1 +% When you use the \var{-vu} flag, the compiler warns that it +% has will not reload the unit because it is already in a second recompile +unit_u_flag_for_reload=10051_U_Vlaggen voor herladen: $1 +% When you use the \var{-vu} flag, the compiler warns that it +% has to reload the unit +unit_u_forced_reload=10052_U_Verplicht herladen +% When you use the \var{-vu} flag, the compiler warns that it +% has is reloading the unit because it was required +unit_u_previous_state=10053_U_Vorige toestand van $1: $2 +% When you use the \var{-vu} flag, the compiler shows the +% previous state of the unit +unit_u_second_compile_unit=10054_U_$1 wordt reeds gecompileerd, tweede compile wordt gezet +% When you use the \var{-vu} flag, the compiler warns that it starts +% recompiling a unit for the second time. This can happend with interdepend +% units. +unit_u_loading_unit=10055_U_Laden unit $1 +% When you use the \var{-vu} flag, the compiler warns that it starts +% loading the unit. +unit_u_finished_loading_unit=10056_U_Klaar met laden van unit $1 +% When you use the \var{-vu} flag, the compiler warns that it finished +% loading the unit. +unit_u_registering_new_unit=10057_U_Nieuwe unit $1 wordt geregistreerd +% When you use the \var{-vu} flag, the compiler warns that it has +% found a new unit and registers it in the internal lists. +unit_u_reresolving_unit=10058_U_Opnieuw oplossen van unit $1 +% When you use the \var{-vu} flag, the compiler warns that it +% has to recalculate the internal data of the unit +unit_u_skipping_reresolving_unit=10059_U_Oplossen van unit $1 wordt overgeslagen, gebruikte units worden nog geladen +% When you use the \var{-vu} flag, the compiler warns that it +% skips to recalculate the internal data of the unit because there +% is no data to recalculate +% \end{description} +# EndOfTeX + +# +# Options +# +# 11039 is the last used one +# +option_usage=11000_$1 [opties] <bestand> [opties] +# BeginOfTeX +% +% \section{Command-line handling errors} +% This section lists errors that occur when the compiler is processing the +% command line or handling the configuration files. +% \begin{description} +option_only_one_source_support=11001_W_Maar een (1) bronbestand wordt ondersteunt +% You can specify only one source file on the command line. The first +% one will be compiled, others will be ignored. This may indicate that +% you forgot a \var{'-'} sign. +option_def_only_for_os2=11002_W_Een DEF file kan alleen worden gemaakt voor OS/2 +% This option can only be specified when you're compiling for OS/2 +option_no_nested_response_file=11003_E_Geneste optie bestanden niet ondersteund +% you cannot nest response files with the \var{@file} command-line option. +option_no_source_found=11004_F_Geen bronbestand op de commando-lijn +% The compiler expects a source file name on the command line. +option_no_option_found=11005_N_geen opties in configuratie bestand $1 +% The compiler didn't find any option in that config file. +option_illegal_para=11006_E_Ongeldige parameter: $1 +% You specified an unknown option. +option_help_pages_para=11007_H_-? druk hulp af +% When an unknown option is given, this message is diplayed. +option_too_many_cfg_files=11008_F_Te veel geneste instellingsbestanden +% You can only nest up to 16 config files. +option_unable_open_file=11009_F_Kan bestand $1 niet openen +% The option file cannot be found. +option_reading_further_from=11010_D_Meer instellingen worden gelezen van $1 +% Displayed when you have notes turned on, and the compiler switches +% to another options file. +option_target_is_already_set=11011_W_Doel is reeds ingesteld op: $1 +% Displayed if more than one \var{-T} option is specified. +option_no_shared_lib_under_dos=11012_W_Shared bibliotheken niet onderteund onder DOS, val terug op statisch +% If you specify \var{-CD} for the \dos platform, this message is displayed. +% The compiler supports only static libraries under \dos +option_too_many_ifdef=11013_F_Te veel IF(N)DEFs +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_too_many_endif=11014_F_Te veel ENDIFs +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_too_less_endif=11015_F_Open voorwaardelijke aan eind van bestand +% the \var{\#IF(N)DEF} statements in the options file are not balanced with +% the \var{\#ENDIF} statements. +option_no_debug_support=11016_W_Debug informatie generatie wordt niet ondersteund door deze applicatie +% It is possible to have a compiler executable that doesn't support +% the generation of debugging info. If you use such an executable with the +% \var{-g} switch, this warning will be displayed. +option_no_debug_support_recompile_fpc=11017_H_Hercompileer de compiler-applicatie met -dGDB +% It is possible to have a compiler executable that doesn't support +% the generation of debugging info. If you use such an executable with the +% \var{-g} switch, this warning will be displayed. +option_obsolete_switch=11018_E_U gebruikt een in onbruik geraakte schakeloptie $1 +% this warns you when you use a switch that is not needed/supported anymore. +% It is recommended that you remove the switch to overcome problems in the +% future, when the switch meaning may change. +option_obsolete_switch_use_new=11019_E_U gebruikt een in onbruik geraakte schakeloptie $1, gebruik $2 a.u.b. +% this warns you when you use a switch that is not supported anymore. You +% must now use the second switch instead. +% It is recommended that you change the switch to overcome problems in the +% future, when the switch meaning may change. +option_switch_bin_to_src_assembler=11020_N_De assembler wordt veranderd in de standaard assemblerschrijver +% this notifies you that the assembler has been changed because you used the +% -a switch which can't be used with a binary assembler writer. +option_incompatible_asm=11021_W_Geselecteerde assembler "$1" is niet verenigbaar met "$2" +option_asm_forced=11022_W_Gebruik van "$1" assembler opgelegd +% The assembler output selected can not generate +% object files with the correct format. Therefore, the +% default assembler for this target is used instead. +%\end{description} +# EndOfTeX + +# +# Logo (option -l) +# +option_using_file=11026_T_Opties worden gelezen van bestand $1 +% Options are also read from this file +option_using_env=11027_T_Opties worden gelezen van omgevingsvariabelen $1 +% Options are also read from this environment string +option_handling_option=11028_D_Behandelen van optie "$1" +% Debug info that an option is found and will be handled +option_help_press_enter=11029__***Druk op de ENTER toets*** +option_start_reading_configfile=11030_H_Start lezen van configuratie bestand $1 +% Starting of config file parsing. +option_end_reading_configfile=11031_H_Einde van lezen van configuratie bestand $1 +% End of config file parsing. +option_interpreting_option=11032_D_Optie $1 wordt behandeld +option_interpreting_firstpass_option=11036_D_Behandel prioritaire optie "$1" +option_interpreting_file_option=11033_D_Behandel bestandsoptie "$1" +option_read_config_file=11034_D_Lezen configuratie bestand "$1" +option_found_file=11035_D_Bronbestand "$1" gevonden +% Additional infos about options, displayed +% when you have debug option turned on. +option_code_page_not_available=11039_E_Ongekende coderingspagina +%\end{description} +# EndOfTeX + +# +# Logo (option -l) +# +option_logo=11023_[ +Free Pascal Compiler versie $FPCVER [$FPCDATE] voor $FPCTARGET +Copyright (c) 1998-2004 door Florian Klaempfl en anderen +] + +# +# Info (option -i) +# +option_info=11024_[ +Free Pascal Compiler versie $FPCVER + +Compiler datum: $FPCDATE +Compiler doelsysteem: $FPCTARGET + +Dit programma wordt verspreid onder de GNU General Public Licence +Voor meer informatie, lees COPYING.FPC. Hiervan is helaas geen +Nederlandse vertaling beschikbaar. + + bugrep@freepascal.org +] + +# +# Help pages (option -? and -h) +# +option_help_pages=11025_[ +**0*_+ schakelt optie aan, - af +**1a_De compiler verwijdert gegenereerd assemblerbestand niet +**2al_Toon broncode in assemblerbestand +**2ar_Toon register allocatie/release informatie in assemblerbestand +**2at_Toon tijdelijke allocatie/release informatie in assemblerbestand +**1b_genereer browser info +**2bl_genereer info voor lokale symbolen info +**1B_Bouw alle modules +**1C_Codegeneratie opties +3*2CD_Creeer dynamische bibliotheek +**2Ch<n>_<n> bytes heap (tussen 1023 en 67107840) +**2Ci_IO-checking +**2Cn_Laat linken achterwege +**2Co_Controleer overflow van integeroperaties +**2Cr_Bereikcontrole (range check) +**2Cs<n>_Stel stack grootte in op <n> +**2Ct_Stack controle +3*2CS_Cre‰er dynamische bibliotheek +3*2Cx_Gebruik slim linken +**1d<x>_definieer het symbool <x> +*O1D_genereer een DEF bestand +*O2Dd<x>_Zet beschrijving op <x> +*O2Dw_PM applicatie +**1e<x>_Zet pad naar applicaties +**1E_Zelfde als -Cn +**1F_Zet bestandsnamen en paden +**2Fe<x>_Zend foutboodschappen naar bestand <x> +*L2Fg<x>_Zelfde als -Fl +**2Fi<x>_Voegt <x> toe aan invoegpad +**2Fl<x>_Voegt <x> toe aan bibliotheek-pad +*L2FL<x>_Gebruik <x> als dynamische linker +**2Fo<x>_Voeg <x> toe aan object-pad +**2Fr<x>_Lees foutmeldingen uit bestand <x> +**2Fu<x>_Voeg <x> toe aan unit pad +**2FU<x>_Schrijf units in folder <x>, (primeert op -FE) +*g1g_genereer debuginformatie +*g2gg_gebruik gsym +*g2gd_gebruik dbx +*g2gh_laad heaptrc unit automatisch +*g2gl_Gebruik regelinformatie unit voor meer informatie in backtraces +*g2gc_genereer controles voor pointers +**1i_informatie +**2iD_Toon compilerdatum +**2iV_Toon compilerversie +**2iSO_Toon compiler-OS +**2iSP_Toon compilerprocessor +**2iTO_Toon doel-OS +**2iTP_Toon doelprocessor +**1I<x>_Voeg <x> toe aan invoegpad +**1k<x>_Geef <x> door aan de linker +**1l_Druk logo af +**1n_Standaard configuratie bestand niet lezen +**1o<x>_Stel de naam van het applicatiebestand in op <x> +**1pg_genereer profile code voor gprof +*L1P_Gebruik pipes in plaats van tijdelijke assembler bestanden +**1S_Syntax instellingen +**2S2_Stel Delphi 2 uitbreidingen in +**2Sc_Ondersteun operatoren als in C (*=,+=,/= en -=) +**2sa_Voeg assertion code toe +**2S2_Tracht Delphi compatibel te zijn +**2Se<x>_Compiler stopt na <x> fouten (standaard 1) +**2Sg_Laat LABEL en GOTO toe +**2Sh_Gebruik ansistrings +**2Si_Ondersteun INLINE +**2Sm_Ondersteun macros zoals in C (globaal) +**2So_Probeer TP/BP 7.0 compatibel te zijn +**2Sp_Probeer GNU Pascal compatibel te zijn +**2Ss_Constructor naam moet init zijn (destructor moet done zijn) +**2St_Sta static sleutelwoord toe in objecten +**1s_Roep assembler en linker niet op (slechts met -a) +**1sh_Genereer een script om op het hostplatform te linken +**1sr_Voer geen registertoewijzing uit (optimalizaties worden uitgeschakeld) +**1st_Genereer een script om op het doelplatform te linken +**1u<x>_Verwijdert symbooldefinitie <x> +**1U_unit opties +**2Un_Unit naam niet nagaan +**2Us_Compileer een systeemunit +**1v<x>_Wees uitvoerig. <x> is een combinatie van volgende letters: +**2*_e : Toon fouten (standaard) d : Toon debug informatie +**2*_w : Toon waarschuwingen u : Toon gebruikte bestanden +**2*_n : Toon notas t : Toon geteste bestanden +**2*_h : Toon hints m : Toon gedefinieerde macros +**2*_i : Toon algemene informatie p : Toon gecompileerde routines +**2*_l : Toon regelnummers c : Toon voorwaardelijken +**2*_a : Toon alles 0 : Toon alleen fouten +**2*_b : Toon alle procedures r : Rhide/GCC compatibiliteit modus +**2*_ declaraties indien een x : Executable informatie (alleen Win32) +**2*_ fout optreedt +**1X_applicatie instellingen +*L2Xc_link met de C bibliotheek +**2Xs_verwijder alle symbolen uit applicatie +**2XD_link met dynamische bibliotheken (definieert FPC_LINK_DYNAMIC) +**2XS_link met statische bibliotheken (definieert FPC_LINK_STATIC) +**2XS_link slim (definieert FPC_LINK_STATIC_SMART) +**0*_Processor specifieke instellingen: +3*1A_Output formaat +3*2Aas_assembleer met GNU AS +3*2Aasaout_assembleer met GNU AS voor aout (Go32v1) +3*2Anasmcoff_Coff (Go32v2) bestand met Nasm +3*2Anasmelf_elf32 (linux) bestand met Nasm +3*2Anasmobj_obj bestand met Nasm +3*2Amasm_obj bestand met Masm (Microsoft) +3*2Atasm_obj bestand met Tasm (Borland) +3*2Acoff_coff (Go32v2) met interne assembler +3*2Apecoff_pecoff (Win32) met interne assembler +3*1R<x>_Geef de grammatica voor de assemblerlezer op: +3*2Ratt_Lees assembler in AT&T stijl +3*2Rintel_Lees assembler in Intel stijl +3*2Rdirect_Kopieer assemblercode rechtstreeks naar assemblerbestand +3*1O<x>_optimalizaties +3*2Og_Genereer kleinere code +3*2OG_Genereerd snellere code (standaard) +3*2Or_Houdt zekere variabelen in registers (Nog steeds BUGGY!!!) +3*2Ou_Probeer onzekere optimalizaties (zie documentatie) +3*2O1_Niveau 1 optimalizaties (snelle optimizaties) +3*2O2_Niveau 2 optimalizaties (-O1 + tragere optimizaties) +3*2O3_Niveau 3 optimalizaties (Zelfde als -O2u) +3*2Op_Doelprocessor +3*3Op1_Stel doelprocessor in op 386/486 +3*3Op2_Stel doelprocessor in op Pentium/PentiumMMX (tm) +3*3Op3_Stel doelprocessor in op PPro/PII/c6x86/K6 (tm) +6*1T<x>_Doel besturingssysteem: +3*2TGO32V2_version 2 of DJ Delorie DOS extender +3*2TLINUX_Linux +3*2TOS2_OS/2 / eComStation +3*2TWIN32_Windows 32 Bit +3*1W<x>_Win32 Doel opties +3*2WB<x>_Stel Image base in op (hexadecimale) waarde <x> +3*2WC_Maak een console applicatie +3*2WD_Gebruik DEFFILE om functies van bibliotheek of applicatie te exporteren +3*2WG_Maak een grafische applicatie +3*2WN_Genereer geen relocatie code (nodig voor debuggen) +3*2WR_Genereer relocatie code +6*1A_output formaat +6*2Aas_Unix o-bestand met GNU AS +6*2Agas_GNU Motorola assembler +6*2Amit_MIT Syntax (oude GAS) +6*2Amot_Standaard Motorola assembler +6*1O_optimizaties +6*2Oa_Gebruik de optimizaties +6*2Og_Genereer kleinere code +6*2OG_Genereer snellere code (standaard) +6*2Ox_Optimizeer maximaal (nog steeds BUGGY!!!) +6*2O2_Stel doelprocessor in op MC68020+ +6*1R<x>_assembler reading style: +6*2RMOT_read motorola style assembler +6*1T<x>_Target operating system: +6*2TAMIGA_Commodore Amiga +6*2TATARI_Atari ST/STe/TT +6*2TMACOS_Macintosh m68k +6*2TLINUX_Linux-68k +**1*_ +**1?_Toont deze hulp +**1h_Toont deze hulp zonder wachten +] + +# +# The End... |