summaryrefslogtreecommitdiff
path: root/drivers/thermal/imx_thermal.c
diff options
context:
space:
mode:
authorAnson Huang <b20788@freescale.com>2014-06-20 15:03:06 +0800
committerZhang Rui <rui.zhang@intel.com>2014-07-01 09:22:28 +0800
commitd0f9d64a0b8fb3399ca8dd0d54f4d305492c9217 (patch)
treedfc65ef5f7f99cde5f49591481b9a0e056e76a9b /drivers/thermal/imx_thermal.c
parentdd354b84d47ec8ca53686bdb3cc1aecdeb75bef5 (diff)
downloadlinux-next-d0f9d64a0b8fb3399ca8dd0d54f4d305492c9217.tar.gz
Thermal: imx: correct critical trip temperature setting
On latest i.MX6 SOC with thermal calibration data of 0x5A100000, the critical trip temperature will be an invalid value and cause system auto shutdown as below log: thermal thermal_zone0: critical temperature reached(42 C),shutting down So, with universal formula for thermal sensor, only room temperature point is calibrated, which means the calibration data read from fuse only has valid data of bit [31:20], others are all 0, the critical trip point temperature can NOT depend on the hot point calibration data, here we set it to 20 C higher than default passive temperature. Signed-off-by: Anson Huang <b20788@freescale.com> Acked-by: Shawn Guo <shawn.guo@linaro.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'drivers/thermal/imx_thermal.c')
-rw-r--r--drivers/thermal/imx_thermal.c18
1 files changed, 7 insertions, 11 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index a99c63152b8d..2c516f2eebed 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -306,7 +306,7 @@ static int imx_get_sensor_data(struct platform_device *pdev)
{
struct imx_thermal_data *data = platform_get_drvdata(pdev);
struct regmap *map;
- int t1, t2, n1, n2;
+ int t1, n1;
int ret;
u32 val;
u64 temp64;
@@ -333,14 +333,10 @@ static int imx_get_sensor_data(struct platform_device *pdev)
/*
* Sensor data layout:
* [31:20] - sensor value @ 25C
- * [19:8] - sensor value of hot
- * [7:0] - hot temperature value
* Use universal formula now and only need sensor value @ 25C
* slope = 0.4297157 - (0.0015976 * 25C fuse)
*/
n1 = val >> 20;
- n2 = (val & 0xfff00) >> 8;
- t2 = val & 0xff;
t1 = 25; /* t1 always 25C */
/*
@@ -366,16 +362,16 @@ static int imx_get_sensor_data(struct platform_device *pdev)
data->c2 = n1 * data->c1 + 1000 * t1;
/*
- * Set the default passive cooling trip point to 20 °C below the
- * maximum die temperature. Can be changed from userspace.
+ * Set the default passive cooling trip point,
+ * can be changed from userspace.
*/
- data->temp_passive = 1000 * (t2 - 20);
+ data->temp_passive = IMX_TEMP_PASSIVE;
/*
- * The maximum die temperature is t2, let's give 5 °C cushion
- * for noise and possible temperature rise between measurements.
+ * The maximum die temperature set to 20 C higher than
+ * IMX_TEMP_PASSIVE.
*/
- data->temp_critical = 1000 * (t2 - 5);
+ data->temp_critical = 1000 * 20 + data->temp_passive;
return 0;
}