summaryrefslogtreecommitdiff
path: root/security
diff options
context:
space:
mode:
authorKrzysztof Kozlowski <k.kozlowski@samsung.com>2016-06-16 08:27:35 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2016-06-25 13:50:53 -0700
commite51e4d8a185de90424b03f30181b35f29c46a25a (patch)
treee4c00a5cc9b8e720e347239cc074e61e2d52674d /security
parent4da22f1418cb6f09e974499794db2f5e59fe8090 (diff)
downloadlinux-next-e51e4d8a185de90424b03f30181b35f29c46a25a.tar.gz
serial: samsung: Fix ERR pointer dereference on deferred probe
When the clk_get() of "uart" clock returns EPROBE_DEFER, the next re-probe finishes with success but uses invalid (ERR_PTR) values. This leads to dereferencing of ERR_PTR stored under ourport->clk: 12c30000.serial: Controller clock not found (...) 12c30000.serial: ttySAC3 at MMIO 0x12c30000 (irq = 61, base_baud = 0) is a S3C6400/10 Unable to handle kernel paging request at virtual address fffffdfb (clk_prepare) from [<c039f7d0>] (s3c24xx_serial_pm+0x20/0x128) (s3c24xx_serial_pm) from [<c0395414>] (uart_change_pm+0x38/0x40) (uart_change_pm) from [<c039689c>] (uart_add_one_port+0x31c/0x44c) (uart_add_one_port) from [<c03a035c>] (s3c24xx_serial_probe+0x2a8/0x418) (s3c24xx_serial_probe) from [<c03ee110>] (platform_drv_probe+0x50/0xb0) (platform_drv_probe) from [<c03ecb44>] (driver_probe_device+0x1f4/0x2b0) (driver_probe_device) from [<c03eb0c0>] (bus_for_each_drv+0x44/0x8c) (bus_for_each_drv) from [<c03ec8c8>] (__device_attach+0x9c/0x100) (__device_attach) from [<c03ebf54>] (bus_probe_device+0x84/0x8c) (bus_probe_device) from [<c03ec388>] (deferred_probe_work_func+0x60/0x8c) (deferred_probe_work_func) from [<c012fee4>] (process_one_work+0x120/0x328) (process_one_work) from [<c0130150>] (worker_thread+0x2c/0x4ac) (worker_thread) from [<c0135320>] (kthread+0xd8/0xf4) (kthread) from [<c0107978>] (ret_from_fork+0x14/0x3c) The first unsuccessful clk_get() causes s3c24xx_serial_init_port() to exit with failure but the s3c24xx_uart_port is left half-configured (e.g. port->mapbase is set, clk contains ERR_PTR). On next re-probe, the function s3c24xx_serial_init_port() will exit early with success because of configured port->mapbase and driver will use old values, including the ERR_PTR as clock. Fix this by cleaning the port->mapbase on error path so each re-probe will initialize all of the port settings. Fixes: 60e93575476f ("serial: samsung: enable clock before clearing pending interrupts during init") Cc: <stable@vger.kernel.org> Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Reviewed-by: Javier Martinez Canillas <javier@osg.samsung.com> Tested-by: Javier Martinez Canillas <javier@osg.samsung.com> Tested-by: Kevin Hilman <khilman@baylibre.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Diffstat (limited to 'security')
0 files changed, 0 insertions, 0 deletions