Documentation: DT: Add entry for ARM SP805-WDT
This patch adds a devicetree binding documentation for ARM's SP805 WatchDog Timer. Signed-off-by: Bhupesh Sharma <bhupesh.sharma@freescale.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Diffstat (limited to 'Documentation/devicetree/bindings/watchdog')
-rw-r--r--Documentation/devicetree/bindings/watchdog/sp805-wdt.txt31
1 files changed, 31 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
new file mode 100644
index 000000000000..edc4f0ea54a3
--- /dev/null
+++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
@@ -0,0 +1,31 @@
+* ARM SP805 Watchdog Timer (WDT) Controller
+
+SP805 WDT is a ARM Primecell Peripheral and has a standard-id register that
+can be used to identify the peripheral type, vendor, and revision.
+This value can be used for driver matching.
+
+As SP805 WDT is a primecell IP, it follows the base bindings specified in
+'arm/primecell.txt'
+
+Required properties:
+- compatible : Should be "arm,sp805-wdt", "arm,primecell"
+- reg : Base address and size of the watchdog timer registers.
+- clocks : From common clock binding.
+ First clock is PCLK and the second is WDOGCLK.
+ WDOGCLK can be equal to or be a sub-multiple of the PCLK frequency.
+- clock-names : From common clock binding.
+ Shall be "apb_pclk" for first clock and "wdog_clk" for the
+ second one.
+
+Optional properties:
+- interrupts : Should specify WDT interrupt number.
+
+Examples:
+
+ cluster1_core0_watchdog: wdt@c000000 {
+ compatible = "arm,sp805-wdt", "arm,primecell";
+ reg = <0x0 0xc000000 0x0 0x1000>;
+ clocks = <&clockgen 4 3>, <&clockgen 4 3>;
+ clock-names = "apb_pclk", "wdog_clk";
+ };
+