diff options
Diffstat (limited to 'Documentation/devicetree')
-rw-r--r-- | Documentation/devicetree/bindings/timer/arm,sp804.txt | 29 |
1 files changed, 29 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.txt b/Documentation/devicetree/bindings/timer/arm,sp804.txt new file mode 100644 index 000000000000..5cd8eee74af1 --- /dev/null +++ b/Documentation/devicetree/bindings/timer/arm,sp804.txt @@ -0,0 +1,29 @@ +ARM sp804 Dual Timers +--------------------------------------- + +Required properties: +- compatible: Should be "arm,sp804" & "arm,primecell" +- interrupts: Should contain the list of Dual Timer interrupts. This is the + interrupt for timer 1 and timer 2. In the case of a single entry, it is + the combined interrupt or if "arm,sp804-has-irq" is present that + specifies which timer interrupt is connected. +- reg: Should contain location and length for dual timer register. +- clocks: clocks driving the dual timer hardware. This list should be 1 or 3 + clocks. With 3 clocks, the order is timer0 clock, timer1 clock, + apb_pclk. A single clock can also be specified if the same clock is + used for all clock inputs. + +Optional properties: +- arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this + specifies if the irq connection is for timer 1 or timer 2. A value of 1 + or 2 should be used. + +Example: + + timer0: timer@fc800000 { + compatible = "arm,sp804", "arm,primecell"; + reg = <0xfc800000 0x1000>; + interrupts = <0 0 4>, <0 1 4>; + clocks = <&timclk1 &timclk2 &pclk>; + clock-names = "timer1", "timer2", "apb_pclk"; + }; |