diff options
author | Peter Hutterer <peter.hutterer@who-t.net> | 2011-04-04 15:33:34 +1000 |
---|---|---|
committer | Peter Hutterer <peter.hutterer@who-t.net> | 2011-04-07 11:04:58 +1000 |
commit | fd952b4e69bd2b2f39df36d1d489fecb47e2ae3a (patch) | |
tree | bcb9e0b2d92e4eb393071f0251036b29eb472dae /man | |
parent | 5cf22a3a39799cb1c50298d73c34fd397ad717b1 (diff) | |
download | xf86-input-wacom-fd952b4e69bd2b2f39df36d1d489fecb47e2ae3a.tar.gz |
Don't rotate hotplugged devices.
We only rotate on a per-tablet basis, not per-tool. Don't accept rotation
values on dependent devices (unless they're the same, then be quiet about
it).
Signed-off-by: Peter Hutterer <peter.hutterer@who-t.net>
Acked-by: Ping Cheng <pinglinux@gmail.com>
Diffstat (limited to 'man')
-rw-r--r-- | man/wacom.man | 4 |
1 files changed, 3 insertions, 1 deletions
diff --git a/man/wacom.man b/man/wacom.man index 1594836..797b388 100644 --- a/man/wacom.man +++ b/man/wacom.man @@ -138,7 +138,9 @@ can be an integer from -1 to 5. Default is 3 for capacitive tools and .B Option \fI"Rotate"\fP \fI"CW"|"CCW"|"HALF"|"NONE"\fP rotates the tablet orientation counterclockwise (CCW) or clockwise (CW) or 180 degrees (HALF). If you have specific tablet mappings, i.e. TopX/Y or BottomX/Y were set, the mapping will be -applied before rotation. The default is "NONE". +applied before rotation. Rotation must be applied to the parent device +(usually the stylus), rotation settings on hotplugged devices will be +ignored. The default is "NONE". .TP 4 .B Option \fI"PressCurve"\fP \fI"x1,y1,x2,y2"\fP sets pressure curve by control points x1, y1, x2, and y2. Their values are in range |