# Configuration file for the Gigabyte GA-M56S-S3
# contributed by Clipo.
# 16-03-2019
# Updates welcome.
# CPU sensor
chip "k8temp-*"
label temp1 "Core0 Temp"
label temp2 "Core0 Temp"
label temp3 "Core1 Temp"
label temp4 "Core1 Temp"
# Motherboard sensors
chip "it8716-*"
### Voltages
label in0 "VCore"
label in1 "VDDR"
label in2 "+3.3V" # VCC3
label in3 "+5V" # VCC
label in4 "+12V"
ignore in5 # "-12V"
ignore in6 # "-5V"
label in7 "5VSB" # VCCH
label in8 "VBat"
# "Vcore", "DDR2 1.8V", "+3.3V" and "Vbat" are connected directly, so no compute
# line is needed for these.
compute in3 ((6.8/10)+1)*@ , @/((6.8/10)+1)
compute in4 ((30/10)+1)*@ , @/((30/10)+1)
# compute in5 (1+232/56)*@ - 4.096*232/56 , (@ + 4.096*232/56)/(1+232/56)
# compute in6 (1+120/56)*@ - 4.096*120/56 , (@ + 4.096*120/56)/(1+120/56)
compute in7 ((6.8/10)+1)*@ , @/((6.8/10)+1)
#
# The BIOS will not set any limit for voltages.
set in0_min 0.825 * 0.95
set in0_max 1.425 * 1.05
set in1_min 1.8 * 0.95
set in1_max 1.8 * 1.05
set in2_min 3.3 * 0.95
set in2_max 3.3 * 1.05
set in3_min 5 * 0.95
set in3_max 5 * 1.05
set in4_min 12 * 0.95
set in4_max 12 * 1.05
set in7_min 5 * 0.95
set in7_max 5 * 1.05
### Temperatures
label temp1 "System Temp"
# This sensor appears to be around or inside the ITE8716F chip.
set temp1_min 0
set temp1_max 40
label temp3 "CPU Temp (Thermal Diode)"
# This sensor can show 2 degrees difference to the K8 sensor.
# The end user can choose which one they prefer.
set temp3_min 0
set temp3_max 60 # Set to match your BIOS "CPU Warning Temperature"
ignore temp2 #"Second CPU Temp (Thermistor)"
#This sensors appears to follow the CPU temp but with a large termal lag so not very usable
### Fans
# Label based on motherboard connectors.
label fan1 "CPU Fan" # M/B label: CPU_FAN (4-pin)
label fan2 "System Fan" # M/B label: SYS_FAN (3-pin)
# Minimum fan speeds.
# Comment/un-comment fan headers you are using if you want alarms.
set fan1_min 300 # CPU Fan
set fan2_min 300 # System Fan 1
|