Manpage changes for flashnode submode support for host mode.
Signed-off-by: Adheer Chandravanshi <adheer.chandravanshi@qlogic.com> Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Diffstat (limited to 'doc')
-rw-r--r--doc/iscsiadm.835
1 files changed, 31 insertions, 4 deletions
diff --git a/doc/iscsiadm.8 b/doc/iscsiadm.8
index 7c209f6..b4c7388 100644
--- a/doc/iscsiadm.8
+++ b/doc/iscsiadm.8
@@ -16,7 +16,7 @@ iscsiadm \- open-iscsi administration utility
\fBiscsiadm\fR \-m fw [\-l]
-\fBiscsiadm\fR \-m host [ \-P printlevel ] [ \-H hostno|MAC ] [ -C chap [ -o operation ] [ -v chap_tbl_idx ] ]
+\fBiscsiadm\fR \-m host [ \-P printlevel ] [ \-H hostno|MAC ] [ [ \-C chap [ \-o operation ] [ \-v chap_tbl_idx ] ] | [ \-C flashnode [ \-o operation ] [ \-A portal_type ] [ \-x flashnode_idx ] [ \-n name ] [ \-v value ] ] ]
\fBiscsiadm\fR \-k priority
@@ -47,6 +47,12 @@ daemon (iscsid) be running.
This option is only valid for ping submode.
.TP
+\fB\-A\fR, \fB\-\-portal_type=\fI[ipv4|ipv6]\fR
+Specify the portal type for the new flash node entry to be created.
+.IP
+This option is only valid for flashnode submode of host mode and only with \fInew\fR operation.
+
+.TP
\fB\-b\fR, \fB\-\-packetsize=\fIpacketsize\fP
Specify the ping \fIpacketsize\fR.
@@ -66,6 +72,12 @@ Currently iscsiadm support ping as submode for iface. For example,
iscsiadm -m iface -I ifacename -C ping -a ipaddr -b packetsize -c count -i interval
+For host, it supports chap and flashnode as submodes. For example,
+
+iscsiadm -m host -H hostno -C chap -v chap_tbl_idx -o operation
+
+iscsiadm -m host -H hostno -C flashnode -x flashnode_idx -o operation
+
.TP
\fB\-d\fR, \fB\-\-debug=\fIdebug_level\fP
print debugging information. Valid values for debug_level are 0 to 8.
@@ -170,8 +182,9 @@ for \fIiface\fR, all ifaces setup in /etc/iscsi/ifaces are displayed.
.TP
\fB\-n\fR, \fB\-\-name=\fIname\fR
-Specify a field \fIname\fR in a record. For use with the \fIupdate\fR
-operator.
+In node mode, specify a field \fIname\fR in a record. In flashnode submode of host mode, specify name of the flash node parameter.
+
+For use with the \fIupdate\fR operator.
.IP
.TP
@@ -181,6 +194,8 @@ Specifies a database operator \fIop\fR. \fIop\fR must be one of
.IP
For iface mode, \fIapply\fR and \fIapplyall\fR are also applicable.
.IP
+For flashnode submode of host mode, \fIlogin\fR and \fIlogout\fR are also applicable.
+.IP
This option is valid for all modes except fw. Delete should not be used on a running session. If it is iscsiadm will stop the session and then delete the
record.
.IP
@@ -210,6 +225,12 @@ sid is passed in.
.IP
\fIapplyall\fR will cause the network settings to take effect on all the ifaces whose MAC address or host number matches that of the specific host.
+.IP
+\fIlogin\fR will log into the specified flash node entry.
+
+.IP
+\fIlogout\fR does the logout from the given flash node entry.
+
.TP
\fB\-p\fR, \fB\-\-portal=\fIip[:port]\fR
Use target portal with ip-address \fIip\fR and \fIport\fR. If port is not passed
@@ -292,12 +313,18 @@ for session mode).
\fB\-v\fR, \fB\-\-value=\fIvalue\fR
Specify a \fIvalue\fR for use with the \fIupdate\fR operator.
.IP
-This option is only valid for node mode.
+This option is only valid for node mode and flashnode submode of host mode.
.TP
\fB\-V\fR, \fB\-\-version\fR
display version and exit
+.TP
+\fB\-x\fR, \fB\-\-flashnode_idx=\fIindex\fR
+Specify the \fIindex\fR of the flash node to operate on.
+.IP
+This option is only valid for flashnode submode of host mode.
+
.SH DISCOVERY TYPES
iSCSI defines 3 discovery types: SendTargets, SLP, and iSNS.