summaryrefslogtreecommitdiff
path: root/doc/iscsiadm.8
blob: a82805e28fb9d0c397713ebdefeda783f00cb92f (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
.TH ISCSIADM 8 "Sep 2006" "" "Linux Administrator's Manual"
.SH NAME
iscsiadm \- open-iscsi administration utility
.SH SYNOPSIS
.B iscsiadm
.B \-m discoverydb
.RB [ \-hV ]
.RB [ \-d
.IR debug_level ]
.RB [ \-P
.IR printlevel ]
[\
.BI \-I\  iface\  \-t\  type\  \-p\  ip:port
.RB [ \-lD ]
] | [
.RB [ \-p
.I ip:port
.B \-t
.IR type ]
.RB [ \-o
.IR operation ]
.RB [ \-n
.IR name ]
.RB [ \-v
.IR value ]
.RB [ \-lD ]
]

.B iscsiadm
.B \-m discovery
.RB [ \-hV ]
.RB [ \-d
.IR debug_level ]
.RB [ \-P
.IR printlevel ]
[\
.BI \-I\  iface\  \-t\  type\  \-p\  ip:port
.RB [ \-l ]
] | [
.RB [ \-p
.IR ip:port ]
.RB [ \-l | \-D ]
]

.B iscsiadm
.B \-m node
.RB [ \-hV ]
.RB [ \-d
.IR debug_level ]
.RB [ \-P
.IR printlevel ]
.RB [ \-L
.IR all,manual,automatic ]
.RB [ \-U
.IR all,manual,automatic ]
.RB [ \-S ]
[
.RB [ \-T
.IB targetname\  \-p\  ip:port\  \-I\  iface
]
.RB [ \-l | \-u | \-R | \-s ]
]
[
.RB [ \-o
.IR operation ]
.RB [ \-n
.IR name ]
.RB [ \-v
.IR value ]
.RB [ \-p
.IR ip:port ]
]

.B iscsiadm
.B \-m session
.RB [ \-hV ]
.RB [ \-d
.IR debug_level ]
.RB [ \-P
.IR printlevel ]
[
.B \-r
.IR sessionid | sysfsdir
.RB [ \-R ]
.RB [ \-u | \-s | \-o
.IR new ]
]

.B iscsiadm
.B \-m iface
.RB [ \-hV ]
.RB [ \-d
.IR debug_level ]
.RB [ \-P
.IR printlevel ]
[
.BI \-I\  ifacename
|
.BI \-H\  hostno|MAC
]
[
.RB [ \-o
.IR operation ]
.RB [ \-n
.IR name ]
.RB [ \-v
.IR value ]
]
[
.BI \-C\  ping
.RB [ \-a
.IR ip ]
.RB [ \-b
.IR packetsize ]
.RB [ \-c
.IR count ]
.RB [ \-i
.IR interval ]
]

.B iscsiadm
.B \-m fw
.RB [ \-d
.IR debug_level ]
.RB [ \-l ]

.B iscsiadm
.B \-m host
.RB [ \-P
.IR printlevel ]
.RB [ \-H
.IR hostno|MAC ]
[
.RB [\  \-C
.IR chap
.RB [ \-x
.IR chap_tbl_idx ]
] |
.RB [\  \-C
.IR flashnode
.RB [ \-A
.IR portal_type ]
.RB [ \-x
.IR flashnode_idx ]
] |
.RB [\  \-C
.IR stats \ ]
]
[
.RB [ \-o
.IR operation ]
.RB [ \-n
.IR name ]
.RB [ \-v
.IR value ]
]

.B iscsiadm
.B \-k  priority

.SH "DESCRIPTION"
The iscsiadm utility is a command-line tool allowing discovery and login
to iSCSI targets, as well as access and management of the open-iscsi
database.

Open-iscsi does not use the term node as defined by the iSCSI RFC,
where a node is a single iSCSI initiator or target. Open-iscsi uses the
term node to refer to a portal on a target.

For session mode, a session id (sid) is used. The sid of a session can be
found by running iscsiadm \-m session \-P 1. The session id and sysfs
path are not currently persistent and is partially determined by when the
session is setup.

.PP
Note that many of the node and discovery operations require that the iSCSI
daemon (iscsid) be running.

.SH OPTIONS

.TP
\fB\-a\fR, \fB\-\-ip=\fIipaddr\fP
\fIipaddr\fR can be IPv4 or IPv6.

This option is only valid for ping submode.

.TP
\fB\-A\fR, \fB\-\-portal_type=\fI[ipv4|ipv6]\fR
Specify the portal type for the new flash node entry to be created.
.IP
This option is only valid for flashnode submode of host mode and only with \fInew\fR operation.

.TP
\fB\-b\fR, \fB\-\-packetsize=\fIpacketsize\fP
Specify the ping \fIpacketsize\fR.

This option is only valid for ping submode.

.TP
\fB\-c\fR, \fB\-\-count=\fIcount\fP
\fIcount\fR specify number of ping iterations.

This option is only valid for ping submode.

.TP
\fB\-C\fR, \fB\-\-submode=\fIop\fP
Specify the submode for mode. op must be name of submode.

Currently iscsiadm support ping as submode for iface. For example,

iscsiadm \-m iface \-I ifacename \-C ping \-a ipaddr \-b packetsize \-c count \-i interval

For host, it supports chap , flashnode and stats as submodes. For example,

iscsiadm \-m host \-H hostno \-C chap \-x chap_tbl_idx \-o operation

iscsiadm \-m host \-H hostno \-C flashnode \-x flashnode_idx \-o operation

iscsiadm \-m host \-H hostno \-C stats

.TP
\fB\-d\fR, \fB\-\-debug=\fIdebug_level\fP
print debugging information. Valid values for debug_level are 0 to 8.

.TP
\fB\-h\fR, \fB\-\-help\fR
display help text and exit

.TP
\fB\-H\fR, \fB\-\-host=\fI[hostno|MAC]\fR
The host argument specifies the SCSI host to use for the operation. It can be
the scsi host number assigned to the host by the kernel's scsi layer, or the
MAC address of a scsi host.

.TP
\fB\-i\fR, \fB\-\-interval=\fIinterval\fP
\fIinterval\fP specify delay between two ping iterations.

This option is only valid for ping submode.

.TP
\fB\-I\fR, \fB\-\-interface=\fI[iface]\fR
The interface argument specifies the iSCSI interface to use for the operation.
iSCSI interfaces (iface) are defined in /etc/iscsi/ifaces. For hardware
iSCSI (qla4xxx) the iface config must have the hardware address
(iface.hwaddress = port's MAC address)
and the driver/transport_name (iface.transport_name). The iface's name is
then the filename of the iface config. For software iSCSI, the iface config
must have either the hardware address (iface.hwaddress), or the network
layer's interface name (iface.net_ifacename), and it must have the
driver/transport_name

The available drivers/iscsi_transports are tcp (software iSCSI over TCP/IP),
iser (software iSCSI over InfiniBand), or qla4xxx (Qlogic 4XXXX HBAs). The
hwaddress is the MAC address or for software iSCSI it may be the special
value "default" which directs the initiator to not bind the session to a
specific hardware resource and instead allow the network or InfiniBand layer
to decide what to do. There is no need to create an iface config with the default
behavior. If you do not specify an iface, then the default behavior is used.

As mentioned above there is a special iface name default. There are three
others -- cxgb3i, bnx2i and iser, which does not bind the session to a specific card, but will bind the session to the cxgb3i, bnx2i or iser transport. These
are experimental and the use is not supported as a stable interface yet.

In discovery mode multiple interfaces can be specified by passing in multiple
\-I/\-\-interface instances. For example,

"iscsiadm \-m discoverydb \-t st \-p ip:port \-I iface0 \-I iface2 \-\-discover"

Will direct iscsiadm to setup the node db to create records which will create
sessions through the two intefaces passed in.

In node mode, only a single interface is supported in each call to iscsiadm.
.IP
This option is valid for discovery, node and iface mode.

.TP
\fB\-k\fR, \fB\-\-killiscsid=\fI[priority]\fR
Currently priority must be zero. This will immediately stop all iscsid
operations and shutdown iscsid. It does not logout any sessions. Running
this command is the same as doing "killall iscsid". Neither should
normally be used, because if iscsid is doing error recovery or if there
is an error while iscsid is not running, the system may not be able to recover.
This command and iscsid's SIGTERM handling are experimental.

.TP
\fB\-D\fR, \fB\-\-discover\fR
Discover targets using the discovery record with the  \fIrecid\fR matching
the the discovery type and portal passed in. If there is no matching record,
it will be created using the iscsid.conf discovery settings.
This must be passed in \fIdiscoverydb\fR mode to instruct iscsiadm to perform
discovery.
.IP
This option is only valid for SendTargets discovery mode.

.TP
\fB\-l\fR, \fB\-\-login\fR
For node and fw mode, login to a specified record. For discovery mode, login to
all discovered targets.
.IP
This option is only valid for discovery and node modes.

.TP
\fB\-L\fR, \fB\-\-loginall=\fI[all|manual|automatic]\fR
For node mode, login all sessions with the node or conn startup values passed
in or all running session, except ones marked onboot, if all is passed in.
.IP
This option is only valid for node mode (it is valid but not functional
for session mode).


.TP
\fB\-m, \-\-mode \fIop\fR
specify the mode. \fIop\fR
must be one of \fIdiscovery\fR, \fIdiscoverydb\fR, \fInode\fR, \fIfw\fR, \fIhost\fR \fIiface\fR or \fIsession\fR.
.IP
If no other options are specified: for \fIdiscovery\fR, \fIdiscoverydb\fR and
\fInode\fR, all of their respective records are displayed; for \fIsession\fR,
all active sessions and connections are displayed; for \fIfw\fR, all boot
firmware values are displayed; for \fIhost\fR, all iSCSI hosts are displayed;
and for \fIiface\fR, all ifaces setup in /etc/iscsi/ifaces are displayed.

.TP
\fB\-n\fR, \fB\-\-name=\fIname\fR
In node mode, specify a field \fIname\fR in a record. In flashnode submode of host mode, specify name of the flash node parameter.

For use with the \fIupdate\fR operator.
.IP

.TP
\fB\-o\fR, \fB\-\-op=\fIop\fR
Specifies a database operator \fIop\fR. \fIop\fR must be one of
\fInew\fR, \fIdelete\fR, \fIupdate\fR, \fIshow\fR or \fInonpersistent\fR.
.IP
For iface mode, \fIapply\fR and \fIapplyall\fR  are also applicable.
.IP
For flashnode submode of host mode, \fIlogin\fR and \fIlogout\fR are also applicable.
.IP
This option is valid for all modes except fw. Delete should not be used on a running session. If it is iscsiadm will stop the session and then delete the
record.
.IP
\fInew\fR creates a new database record for a given object. In node mode, the
\fIrecid\fR is the target name and portal (IP:port). In iface mode, the \fIrecid\fR
is the iface name. In discovery mode, the \fIrecid\fR is the portal and
discovery type.
.IP
In session mode, the \fInew\fR operation logs in a new session using the same node database and iface information as the specified session.
.IP
In discovery mode, if the \fIrecid\fR and new operation is passed in, but the \fI--discover\fR argument is not, then iscsiadm will only create a discovery record (it will not perform discovery). If the \fI--discover\fR argument is passed in with the portal and discovery type, then iscsiadm will create the discovery record if needed, and it will create records for portals returned by the target that do not yet have a node DB record.
.IP
\fIdelete\fR deletes a specified \fIrecid\fR. In discovery mode, if iscsiadm is performing discovery it will delete records for portals that are no longer returned.
.IP
\fIupdate\fR will update the \fIrecid\fR with \fIname\fR to the specified \fIvalue\fR. In discovery mode, if iscsiadm is performing discovery the \fIrecid\fR, \fIname\fR  and \fIvalue\fR arguments are not needed. The update operation will operate on the portals returned by the target, and will update the node records with info from the config file and command line.
.IP
\fIshow\fR is the default behaviour for node, discovery and iface mode. It is
also used when there are no commands passed into session mode and a running
sid is passed in.
\fIname\fR and \fIvalue\fR are currently ignored when used with \fIshow\fR.
.IP
\fInonpersistent\fR instructs iscsiadm to not manipulate the node DB.

.IP
\fIapply\fR will cause the network settings to take effect on the specified iface.

.IP
\fIapplyall\fR will cause the network settings to take effect on all the ifaces whose MAC address or host number matches that of the specific host.

.IP
\fIlogin\fR will log into the specified flash node entry.

.IP
\fIlogout\fR does the logout from the given flash node entry.

.TP
\fB\-p\fR, \fB\-\-portal=\fIip[:port]\fR
Use target portal with ip-address \fIip\fR and \fIport\fR. If port is not passed
in the default \fIport\fR value is 3260.
.IP
IPv6 addresses can be specified as [ddd.ddd.ddd.ddd]:port or
ddd.ddd.ddd.ddd.
.IP
Hostnames can also be used for the ip argument.

.IP
This option is only valid for discovery, or for node operations with
the \fInew\fR operator.
.IP
This should be used along with \-\-target in node mode, to specify what the open-iscsi docs refer to as a node or node record. Note: open-iscsi's use of the word node, does not match the iSCSI RFC's iSCSI Node term.

.TP
\fB\-P\fR,  \fB\-\-print=\fIprintlevel\fR
If in node mode print nodes in tree format. If in session mode print
sessions in tree format. If in discovery mode print the nodes in
tree format.

.TP
\fB\-T\fR, \fB\-\-targetname=\fItargetname\fR
Use target \fItargetname\fR.
.IP
This should be used along with \-\-portal in node mode, to specify what the open-iscsi docs refer to as a node or node record. Note: open-iscsi's use of the word node, does not match the iSCSI RFC's iSCSI Node term.

.TP
\fB\-r\fR,  \fB\-\-sid=\fIsid | sysfsdir\fR
Use session ID \fIsid\fR. The sid of a session can be found from running
iscsiadm in session mode with the \-\-info argument.

Instead of sid, a sysfs path containing the session can be used. For example using one of the following: /sys/devices/platform/hostH/sessionS/targetH:B:I/H:B:I:L, /sys/devices/platform/hostH/sessionS/targetH:B:I, or /sys/devices/platform/hostH/sessionS, for the sysfsdir argument would result in the session with sid S to be used.
.IP
\fIsid | sysfsdir\fR is only required for session mode.

.TP
\fB\-R\fR,  \fB\-\-rescan\fR
In session mode, if sid is also passed in rescan the session. If no sid has
been passed in  rescan all running sessions.

In node mode, rescan a session running through the target, portal, iface
tuple passed in.

.TP
\fB\-s\fR, \fB\-\-stats\fR
Display session statistics.
This option when used with host mode, displays host statistics.

.TP
\fB\-S\fR, \fB\-\-show\fR
When displaying records, do not hide masked values, such as the CHAP
secret (password).
.IP
This option is only valid for node and session mode.

.TP
\fB\-t\fR, \fB\-\-type=\fItype\fR
\fItype\fR must be \fIsendtargets\fR (or abbreviated as \fIst\fR),
\fIslp\fR, \fIisns\fR or \fIfw\fR. Currently only sendtargets, fw, and
iSNS is supported, see the DISCOVERY TYPES section.
.IP
This option is only valid for discovery mode.

.TP
\fB\-u\fR, \fB\-\-logout\fR
logout for a specified record.
.IP
This option is only valid for node and session mode.

.TP
\fB\-U\fR, \fB\-\-logoutall=\fI[all,manual,automatic]\fR
logout all sessions with the node or conn startup values passed in or all
running session, except ones marked onboot, if all is passed in.
.IP
This option is only valid for node mode (it is valid but not functional
for session mode).

.TP
\fB\-v\fR, \fB\-\-value=\fIvalue\fR
Specify a \fIvalue\fR for use with the \fIupdate\fR operator.
.IP
This option is only valid for node mode and flashnode submode of host mode.

.TP
\fB\-V\fR, \fB\-\-version\fR
display version and exit

.TP
\fB\-x\fR, \fB\-\-index=\fIindex\fR
Specify the \fIindex\fR of the entity to operate on.
.IP
This option is only valid for chap and flashnode submodes of host mode.

.SH DISCOVERY TYPES
iSCSI defines 3 discovery types: SendTargets, SLP, and iSNS.

.TP
.B
SendTargets
A native iSCSI protocol which allows each iSCSI
target to send a list of available targets to the initiator.

.TP
.B
SLP
Optionally an iSCSI target can use the Service Location Protocol (SLP)
to announce the available targets. The initiator can either implement
SLP queries directly or can use a separate tool to acquire the
information about available targets.

.TP
.B
iSNS
iSNS (Internet Storage Name Service) records information about storage
volumes within a larger network. To utilize iSNS, pass the address and
optionally the port of the iSNS server to do discovery to.

.TP
.B
fw
Several NICs and systems contain a mini iSCSI initiator which can be used
for boot. To get the values used for boot the fw option can be used.
Doing fw discovery, does not store persistent records in the node or
discovery DB, because the values are stored in the system's or NIC's
resource.

Performing fw discovery will print the portals, like with other discovery
methods. To see other settings like CHAP values and initiator settings,
like you would in node mode, run "iscsiadm \-m fw".

fw support in open-iscsi is experimental. The settings and iscsiadm
syntax and output format may change.

.P
iscsiadm supports the
.B
iSNS (isns)
or
.B
SendTargets (st)
discovery type. An SLP implementation is under development.

.SH EXIT STATUS

On success 0 is returned. On error one of the return codes below will
be returned.

Commands that operate on multiple objects (sessions, records, etc),
iscsiadm/iscsistart will return the first error that is encountered.
iscsiadm/iscsistart will attempt to execute the operation on the objects it
can. If no objects are found ISCSI_ERR_NO_OBJS_FOUND is returned.


.TP
.B
0
ISCSI_SUCCESS - command executed successfully.

.TP
.B
1
ISCSI_ERR - generic error code.

.TP
.B
2
ISCSI_ERR_SESS_NOT_FOUND - session could not be found.

.TP
.B
3
ISCSI_ERR_NOMEM - could not allocate resource for operation.
.TP
.B
4
ISCSI_ERR_TRANS - connect problem caused operation to fail.

.TP
.B
5
ISCSI_ERR_LOGIN - generic iSCSI login failure.

.TP
.B
6
ISCSI_ERR_IDBM - error accessing/managing iSCSI DB.

.TP
.B
7
ISCSI_ERR_INVAL - invalid argument.

.TP
.B
8
ISCSI_ERR_TRANS_TIMEOUT - connection timer exired while trying to connect.

.TP
.B
9
ISCSI_ERR_INTERNAL - generic internal iscsid/kernel failure.

.TP
.B
10
ISCSI_ERR_LOGOUT - iSCSI logout failed.

.TP
.B
11
ISCSI_ERR_PDU_TIMEOUT - iSCSI PDU timedout.

.TP
.B
12
ISCSI_ERR_TRANS_NOT_FOUND - iSCSI transport module not loaded in kernel or iscsid.

.TP
.B
13
ISCSI_ERR_ACCESS - did not have proper OS permissions to access iscsid or execute iscsiadm command.

.TP
.B
14
ISCSI_ERR_TRANS_CAPS - transport module did not support operation.

.TP
.B
15
ISCSI_ERR_SESS_EXISTS - session is logged in.

.TP
.B
16
ISCSI_ERR_INVALID_MGMT_REQ - invalid IPC MGMT request.

.TP
.B
17
ISCSI_ERR_ISNS_UNAVAILABLE - iSNS service is not supported.

.TP
.B
18
ISCSI_ERR_ISCSID_COMM_ERR - a read/write to iscsid failed.

.TP
.B
19
ISCSI_ERR_FATAL_LOGIN - fatal iSCSI login error.

.TP
.B
20
ISCSI_ERR_ISCSID_NOTCONN - could not connect to iscsid.

.TP
.B
21
ISCSI_ERR_NO_OBJS_FOUND - no records/targets/sessions/portals found to execute operation on.

.TP
.B
22
ISCSI_ERR_SYSFS_LOOKUP - could not lookup object in sysfs.

.TP
.B
23
ISCSI_ERR_HOST_NOT_FOUND - could not lookup host.

.TP
.B
24
ISCSI_ERR_LOGIN_AUTH_FAILED - login failed due to authorization failure.

.TP
.B
25
ISCSI_ERR_ISNS_QUERY - iSNS query failure.

.TP
.B
26
ISCSI_ERR_ISNS_REG_FAILED - iSNS registration/deregistration failed.


.SH EXAMPLES

.nf
Discover targets at a given IP address:

.ft R
	iscsiadm \-\-mode discoverydb \-\-type sendtargets \-\-portal 192.168.1.10 \-\-discover
.nf

Login, must use a node record id found by the discovery:

.ft R
	iscsiadm \-\-mode node \-\-targetname iqn.2001-05.com.doe:test \-\-portal 192.168.1.1:3260 \-\-login
.nf

Logout:

.ft R
	iscsiadm \-\-mode node \-\-targetname iqn.2001-05.com.doe:test \-\-portal 192.168.1.1:3260 \-\-logout
.nf

List node records:

.ft R
	iscsiadm \-\-mode node

.nf

Display all data for a given node record:

.ft R
	iscsiadm \-\-mode node \-\-targetname iqn.2001-05.com.doe:test \-\-portal 192.168.1.1:3260

.SH FILES
.TP
/etc/iscsi/iscsid.conf
The configuration file read by \fBiscsid\fR and \fBiscsiadm\fR on startup.
.TP
/etc/iscsi/initiatorname.iscsi
The file containing the iSCSI InitiatorName and InitiatorAlias read by
\fBiscsid\fR and \fBiscsiadm\fR on startup.
.TP
/etc/iscsi/nodes/
This directory contains the nodes with their targets.
.TP
/etc/iscsi/send_targets
This directory contains the portals.

.SH "SEE ALSO"
.BR iscsid (8)

.SH AUTHORS
Open-iSCSI project <http://www.open-iscsi.com/>
.br
Alex Aizman <itn780@yahoo.com>
.br
Dmitry Yusupov <dmitry_yus@yahoo.com>