summaryrefslogtreecommitdiff
path: root/ceilometer/notification.py
blob: 10281a3d5f9828ef9cc48b84c449b07fe9761305 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
#
# Copyright 2017-2018 Red Hat, Inc.
# Copyright 2012-2013 eNovance <licensing@enovance.com>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
#      http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
import time

import cotyledon
from oslo_config import cfg
from oslo_log import log
import oslo_messaging
from stevedore import named

from ceilometer.i18n import _
from ceilometer import messaging


LOG = log.getLogger(__name__)


OPTS = [
    cfg.BoolOpt('ack_on_event_error',
                default=True,
                help='Acknowledge message when event persistence fails.'),
    cfg.MultiStrOpt('messaging_urls',
                    default=[],
                    secret=True,
                    help="Messaging URLs to listen for notifications. "
                         "Example: rabbit://user:pass@host1:port1"
                         "[,user:pass@hostN:portN]/virtual_host "
                         "(DEFAULT/transport_url is used if empty). This "
                         "is useful when you have dedicate messaging nodes "
                         "for each service, for example, all nova "
                         "notifications go to rabbit-nova:5672, while all "
                         "cinder notifications go to rabbit-cinder:5672."),
    cfg.IntOpt('batch_size',
               default=1, min=1,
               help='Number of notification messages to wait before '
               'publishing them.'),
    cfg.IntOpt('batch_timeout',
               help='Number of seconds to wait before dispatching samples '
                    'when batch_size is not reached (None means indefinitely).'
               ),
    cfg.IntOpt('workers',
               default=1,
               min=1,
               deprecated_group='DEFAULT',
               deprecated_name='notification_workers',
               help='Number of workers for notification service, '
               'default value is 1.'),
    cfg.MultiStrOpt('pipelines',
                    default=['meter', 'event'],
                    help="Select which pipeline managers to enable to "
                    " generate data"),
]


EXCHANGES_OPTS = [
    cfg.MultiStrOpt('notification_control_exchanges',
                    default=['nova', 'glance', 'neutron', 'cinder', 'heat',
                             'keystone', 'sahara', 'trove', 'zaqar', 'swift',
                             'ceilometer', 'magnum', 'dns', 'ironic', 'aodh'],
                    deprecated_group='DEFAULT',
                    deprecated_name="http_control_exchanges",
                    help="Exchanges name to listen for notifications."),
]


class NotificationService(cotyledon.Service):
    """Notification service.

    When running multiple agents, additional queuing sequence is required for
    inter process communication. Each agent has two listeners: one to listen
    to the main OpenStack queue and another listener(and notifier) for IPC to
    divide pipeline sink endpoints. Coordination should be enabled to have
    proper active/active HA.
    """

    NOTIFICATION_NAMESPACE = 'ceilometer.notification.v2'

    def __init__(self, worker_id, conf, coordination_id=None):
        super(NotificationService, self).__init__(worker_id)
        self.startup_delay = worker_id
        self.conf = conf
        self.listeners = []

    def get_targets(self):
        """Return a sequence of oslo_messaging.Target

        This sequence is defining the exchange and topics to be connected.
        """
        topics = (self.conf.notification_topics
                  if 'notification_topics' in self.conf
                  else self.conf.oslo_messaging_notifications.topics)
        return [oslo_messaging.Target(topic=topic, exchange=exchange)
                for topic in set(topics)
                for exchange in
                set(self.conf.notification.notification_control_exchanges)]

    @staticmethod
    def _log_missing_pipeline(names):
        LOG.error(_('Could not load the following pipelines: %s'), names)

    def run(self):
        # Delay startup so workers are jittered
        time.sleep(self.startup_delay)

        super(NotificationService, self).run()

        self.managers = [ext.obj for ext in named.NamedExtensionManager(
            namespace='ceilometer.notification.pipeline',
            names=self.conf.notification.pipelines, invoke_on_load=True,
            on_missing_entrypoints_callback=self._log_missing_pipeline,
            invoke_args=(self.conf,))]

        # FIXME(sileht): endpoint uses the notification_topics option
        # and it should not because this is an oslo_messaging option
        # not a ceilometer. Until we have something to get the
        # notification_topics in another way, we must create a transport
        # to ensure the option has been registered by oslo_messaging.
        messaging.get_notifier(messaging.get_transport(self.conf), '')

        endpoints = []
        for pipe_mgr in self.managers:
            endpoints.extend(pipe_mgr.get_main_endpoints())
        targets = self.get_targets()

        urls = self.conf.notification.messaging_urls or [None]
        for url in urls:
            transport = messaging.get_transport(self.conf, url)
            # NOTE(gordc): ignore batching as we want pull
            # to maintain sequencing as much as possible.
            listener = messaging.get_batch_notification_listener(
                transport, targets, endpoints, allow_requeue=True,
                batch_size=self.conf.notification.batch_size,
                batch_timeout=self.conf.notification.batch_timeout)
            listener.start(
                override_pool_size=self.conf.max_parallel_requests
            )
            self.listeners.append(listener)

    @staticmethod
    def kill_listeners(listeners):
        # NOTE(gordc): correct usage of oslo.messaging listener is to stop(),
        # which stops new messages, and wait(), which processes remaining
        # messages and closes connection
        for listener in listeners:
            listener.stop()
            listener.wait()

    def terminate(self):
        self.kill_listeners(self.listeners)

        super(NotificationService, self).terminate()