diff --git a/doc/source/admin/drivers/idrac.rst b/doc/source/admin/drivers/idrac.rst
index a9c47f5e7..13e39d05c 100644
--- a/doc/source/admin/drivers/idrac.rst
+++ b/doc/source/admin/drivers/idrac.rst
@@ -5,55 +5,573 @@ iDRAC driver
Overview
========
-iDRAC_ hardware is supported by the ``idrac`` hardware type. It is also
-supported by the standard ``ipmi`` hardware type, though with a smaller
-feature set.
+The integrated Dell Remote Access Controller (iDRAC_) is an out-of-band
+management platform on Dell EMC servers, and is supported directly by
+the ``idrac`` hardware type. This driver uses the Dell Web Services for
+Management (WSMAN) protocol and the standard Distributed Management Task
+Force (DMTF) Redfish protocol to perform all of its functions.
-.. TODO(dtantsur): supported hardware
+iDRAC_ hardware is also supported by the generic ``ipmi`` and ``redfish``
+hardware types, though with smaller feature sets.
+
+Key features of the Dell iDRAC driver include:
+
+* Out-of-band node inspection
+* Boot device management
+* Power management
+* RAID controller management and RAID volume configuration
+* BIOS settings configuration
+
+Ironic Features
+---------------
+
+The ``idrac`` hardware type supports the following Ironic interfaces:
+
+* `Inspect Interface`_: Hardware inspection
+* Management Interface: Boot device management
+* Power Interface: Power management
+* `RAID Interface`_: RAID controller and disk management
+* `Vendor Interface`_: BIOS management
+
+Prerequisites
+-------------
+
+The ``idrac`` hardware type requires the ``python-dracclient`` library
+to be installed on the ironic conductor node(s) if an Ironic node is
+configured to use an ``idrac-wsman`` interface implementation, for example::
+
+ sudo pip install 'python-dracclient>=3.1.0'
+
+Additionally, the ``idrac`` hardware type requires the ``sushy`` library
+to be installed on the ironic conductor node(s) if an Ironic node is
+configured to use an ``idrac-redfish`` interface implementation, for example::
+
+ sudo pip install 'python-dracclient>=3.1.0' 'sushy>=2.0.0'
Enabling
-========
+--------
+
+The iDRAC driver supports WSMAN for the inspect, management, power,
+raid, and vendor interfaces. In addition, it supports Redfish for
+the inspect, management, and power interfaces. The iDRAC driver
+allows you to mix and match WSMAN and Redfish interfaces.
-The ``idrac`` hardware type requires the ``python-dracclient`` library to be
-installed, for example::
+The ``idrac-wsman`` implementation must be enabled to use WSMAN for
+an interface. The ``idrac-redfish`` implementation must be enabled
+to use Redfish for an interface.
- sudo pip install 'python-dracclient>=1.5.0,<3.0.0'
+.. NOTE::
+ Redfish is supported for only the inspect, management, and power
+ interfaces at the present time.
-To enable the ``idrac`` hardware type, add the following to your
-``/etc/ironic/ironic.conf``:
+To enable the ``idrac`` hardware type with the minimum interfaces,
+all using WSMAN, add the following to your ``/etc/ironic/ironic.conf``:
.. code-block:: ini
[DEFAULT]
- enabled_hardware_types=idrac
- enabled_management_interfaces=idrac
- enabled_power_interfaces=idrac
+ enabled_hardware_types=idrac-wsman
+ enabled_management_interfaces=idrac-wsman
+ enabled_power_interfaces=idrac-wsman
-To enable all optional features (inspection, RAID and vendor passthru), use
-the following configuration:
+To enable all optional features (inspection, RAID, and vendor passthru)
+using Redfish where it is supported and WSMAN where not, use the
+following configuration:
.. code-block:: ini
[DEFAULT]
enabled_hardware_types=idrac
- enabled_inspect_interfaces=idrac
- enabled_management_interfaces=idrac
- enabled_power_interfaces=idrac
- enabled_raid_interfaces=idrac
- enabled_vendor_interfaces=idrac
+ enabled_inspect_interfaces=idrac-redfish
+ enabled_management_interfaces=idrac-redfish
+ enabled_power_interfaces=idrac-redfish
+ enabled_raid_interfaces=idrac-wsman
+ enabled_vendor_interfaces=idrac-wsman
+
+Below is the list of supported interface implementations in priority
+order:
+
+================ ===================================================
+Interface Supported Implementations
+================ ===================================================
+``bios`` ``no-bios``
+``boot`` ``ipxe``, ``pxe``
+``console`` ``no-console``
+``deploy`` ``iscsi``, ``direct``, ``ansible``, ``ramdisk``
+``inspect`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``,
+ ``inspector``, ``no-inspect``
+``management`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
+``network`` ``flat``, ``neutron``, ``noop``
+``power`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
+``raid`` ``idrac-wsman``, ``idrac``, ``no-raid``
+``rescue`` ``no-rescue``, ``agent``
+``storage`` ``noop``, ``cinder``, ``external``
+``vendor`` ``idrac-wsman``, ``idrac``, ``no-vendor``
+================ ===================================================
+
+.. NOTE::
+ ``idrac`` is the legacy name of the WSMAN interface. It has been
+ deprecated in favor of ``idrac-wsman`` and may be removed in a
+ future release.
+
+Protocol-specific Properties
+----------------------------
+
+The WSMAN and Redfish protocols require different properties to be specified
+in the Ironic node's ``driver_info`` field to communicate with the bare
+metal system's iDRAC.
+
+The WSMAN protocol requires the following properties:
+
+* ``drac_username``: The WSMAN user name to use when communicating
+ with the iDRAC. Usually ``root``.
+* ``drac_password``: The password for the WSMAN user to use when
+ communicating with the iDRAC.
+* ``drac_address``: The IP address of the iDRAC.
+
+The Redfish protocol requires the following properties:
+
+* ``redfish_username``: The Redfish user name to use when
+ communicating with the iDRAC. Usually ``root``.
+* ``redfish_password``: The password for the Redfish user to use
+ when communicating with the iDRAC.
+* ``redfish_address``: The URL address of the iDRAC. It must include the
+ authority portion of the URL, and can optionally include the scheme. If
+ the scheme is missing, https is assumed.
+* ``redfish_system_id``: The Redfish ID of the server to be
+ managed. This should always be: ``/redfish/v1/Systems/System.Embedded.1``.
+
+If using only interfaces which use WSMAN (``idrac-wsman``), then only
+the WSMAN properties must be supplied. If using only interfaces which
+use Redfish (``idrac-redfish``), then only the Redfish properties must be
+supplied. If using a mix of interfaces, where some use WSMAN and others
+use Redfish, both the WSMAN and Redfish properties must be supplied.
Enrolling
-=========
+---------
-The following command will enroll a bare metal node with the ``idrac``
-hardware type::
+The following command enrolls a bare metal node with the ``idrac``
+hardware type using WSMAN for all interfaces:
+
+.. code-block:: bash
+
+ openstack baremetal node create --driver idrac \
+ --driver-info drac_username=user \
+ --driver-info drac_password=pa$$w0rd \
+ --driver-info drac_address=drac.host
+
+The following command enrolls a bare metal node with the ``idrac``
+hardware type using Redfish for all interfaces:
+
+.. code-block:: bash
+
+ openstack baremetal node create --driver idrac \
+ --driver-info redfish_username=user \
+ --driver-info redfish_password=pa$$w0rd \
+ --driver-info redfish_address=drac.host \
+ --driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
+ --inspect-interface idrac-redfish \
+ --management-interface idrac-redfish \
+ --power-interface idrac-redfish \
+ --raid-interface no-raid \
+ --vendor-interface no-vendor
+
+The following command enrolls a bare metal node with the ``idrac``
+hardware type assuming a mix of Redfish and WSMAN interfaces are used:
+
+.. code-block:: bash
openstack baremetal node create --driver idrac \
- --driver-info drac_address=drac.host \
--driver-info drac_username=user \
--driver-info drac_password=pa$$w0rd
+ --driver-info drac_address=drac.host \
+ --driver-info redfish_username=user \
+ --driver-info redfish_password=pa$$w0rd \
+ --driver-info redfish_address=drac.host \
+ --driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
+ --inspect-interface idrac-redfish \
+ --management-interface idrac-redfish \
+ --power-interface idrac-redfish
+
+.. NOTE::
+ If using WSMAN for the management interface, then WSMAN must be used
+ for the power interface. The same applies to Redfish. It is currently not
+ possible to use Redfish for one and WSMAN for the other.
+
+Inspect Interface
+=================
+
+The Dell iDRAC out-of-band inspection process catalogs all the same
+attributes of the server as the IPMI driver. Unlike IPMI, it does this
+without requiring the system to be rebooted, or even to be powered on.
+Inspection is performed using the Dell WSMAN or Redfish protocol directly
+without affecting the operation of the system being inspected.
+
+The inspection discovers the following properties:
+
+* ``cpu_arch``: cpu architecture
+* ``cpus``: number of cpus
+* ``local_gb``: disk size in gigabytes
+* ``memory_mb``: memory size in megabytes
+
+Extra capabilities:
+
+* ``boot_mode``: UEFI or BIOS boot mode.
+
+It also creates baremetal ports for each NIC port detected in the system.
+The ``idrac-wsman`` inspect interface discovers which NIC ports are
+configured to PXE boot and sets ``pxe_enabled`` to ``True`` on those ports.
+The ``idrac-redfish`` inspect interface does not currently set ``pxe_enabled``
+on the ports. The user should ensure that ``pxe_enabled`` is set correctly on
+the ports following inspection with the ``idrac-redfish`` inspect interface.
+
+
+RAID Interface
+==============
+
+See :doc:`/admin/raid` for more information on Ironic RAID support.
+
+The following properties are supported by the iDRAC WSMAN raid interface
+implementation, ``idrac-wsman``:
+
+
+Mandatory properties
+--------------------
+
+* ``size_gb``: Size in gigabytes (integer) for the logical disk. Use ``MAX`` as
+ ``size_gb`` if this logical disk is supposed to use the rest of the space available.
+* ``raid_level``: RAID level for the logical disk. Valid values are
+ ``0``, ``1``, ``5``, ``6``, ``1+0``, ``5+0`` and ``6+0``.
+
+.. NOTE::
+ ``JBOD`` and ``2`` are not supported, and will fail with reason: 'Cannot
+ calculate spans for RAID level.'
+
+Optional properties
+-------------------
+
+* ``is_root_volume``: Optional. Specifies whether this disk is a root volume.
+ By default, this is ``False``.
+* ``volume_name``: Optional. Name of the volume to be created. If this is not
+ specified, it will be auto-generated.
+
+Backing physical disk hints
+---------------------------
+
+See :doc:`/admin/raid` for more information on backing disk hints.
+
+These are machine-independent information. The hints are specified for each
+logical disk to help Ironic find the desired disks for RAID configuration.
+
+* ``disk_type``
+* ``interface_type``
+* ``share_physical_disks``
+* ``number_of_physical_disks``
+
+Backing physical disks
+----------------------
+
+These are Dell RAID controller-specific values and must match the
+names provided by the iDRAC.
+
+* ``controller``: Mandatory. The name of the controller to use.
+* ``physical_disks``: Optional. The names of the physical disks to use.
+
+.. NOTE::
+ ``physical_disks`` is a mandatory parameter if the property ``size_gb`` is set to ``MAX``.
+
+Examples
+--------
+
+Creation of RAID ``1+0`` logical disk with six disks on one controller:
+
+.. code-block:: json
+
+ { "logical_disks":
+ [ { "controller": "RAID.Integrated.1-1",
+ "is_root_volume": "True",
+ "physical_disks": [
+ "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
+ "raid_level": "1+0",
+ "size_gb": "MAX"}]}
+
+
+Manual RAID Invocation
+----------------------
+
+The following command can be used to delete any existing RAID configuration.
+It deletes all virtual disks/RAID volumes, unassigns all global and dedicated
+hot spare physical disks, and clears foreign configuration:
+
+.. code-block:: bash
+
+ openstack baremetal node clean --clean-steps \
+ '[{"interface": "raid", "step": "delete_configuration"}]' ${node_uuid}
+
+
+The following command shows an example of how to set the target RAID
+configuration:
+
+.. code-block:: bash
+
+ openstack baremetal node set --target-raid-config '{ "logical_disks":
+ [ { "controller": "RAID.Integrated.1-1",
+ "is_root_volume": true,
+ "physical_disks": [
+ "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
+ "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
+ "raid_level": "0",
+ "size_gb": "MAX"}]}' ${node_uuid}
+
+
+The following command can be used to create a RAID configuration:
+
+.. code-block:: bash
+
+ openstack baremetal node clean --clean-steps \
+ '[{"interface": "raid", "step": "create_configuration"}]' ${node_uuid}
+
+
+When the physical disk names or controller names are not known, the
+following Python code example shows how the ``python-dracclient`` can
+be used to fetch the information directly from the Dell bare metal:
+
+.. code-block:: python
+
+ import dracclient.client
+
+
+ client = dracclient.client.DRACClient(
+ host="192.168.1.1",
+ username="root",
+ password="calvin")
+ controllers = client.list_raid_controllers()
+ print(controllers)
+
+ physical_disks = client.list_physical_disks()
+ print(physical_disks)
+
+
+Vendor Interface
+================
+
+Dell iDRAC BIOS management is available through the Ironic vendor
+passthru interface.
+
+======================== ============ ======================================
+Method Name HTTP Method Description
+======================== ============ ======================================
+``abandon_bios_config`` ``DELETE`` Abandon a BIOS configuration job.
+``commit_bios_config`` ``POST`` Commit a BIOS configuration job
+ submitted through ``set_bios_config``.
+ Required argument: ``reboot`` -
+ indicates whether a reboot job
+ should be automatically created
+ with the config job. Returns a
+ dictionary containing the ``job_id``
+ key with the ID of the newly created
+ config job, and the
+ ``reboot_required`` key indicating
+ whether the node needs to be rebooted
+ to execute the config job.
+``get_bios_config`` ``GET`` Returns a dictionary containing the
+ node's BIOS settings.
+``list_unfinished_jobs`` ``GET`` Returns a dictionary containing
+ the key ``unfinished_jobs``; its value
+ is a list of dictionaries. Each
+ dictionary represents an unfinished
+ config job object.
+``set_bios_config`` ``POST`` Change the BIOS configuration on
+ a node. Required argument: a
+ dictionary of {``AttributeName``:
+ ``NewValue``}. Returns a dictionary
+ containing the ``is_commit_required``
+ key indicating whether
+ ``commit_bios_config`` needs to be
+ called to apply the changes and the
+ ``is_reboot_required`` value
+ indicating whether the server must
+ also be rebooted. Possible values are
+ ``true`` and ``false``.
+======================== ============ ======================================
+
+
+Examples
+--------
+
+Get BIOS Config
+~~~~~~~~~~~~~~~
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call --http-method GET ${node_uuid} get_bios_config
+
+Snippet of output showing virtualization enabled:
+
+.. code-block:: json
+
+ {"ProcVirtualization": {
+ "current_value": "Enabled",
+ "instance_id": "BIOS.Setup.1-1:ProcVirtualization",
+ "name": "ProcVirtualization",
+ "pending_value": null,
+ "possible_values": [
+ "Enabled",
+ "Disabled"],
+ "read_only": false }}
+
+There are a number of items to note from the above snippet:
+
+* ``name``: this is the name to use in a call to ``set_bios_config``.
+* ``current_value``: the current state of the setting.
+* ``pending_value``: if the value has been set, but not yet committed,
+ the new value is shown here. The change can either be committed or
+ abandoned.
+* ``possible_values``: shows a list of valid values which can be used
+ in a call to ``set_bios_config``.
+* ``read_only``: indicates if the value is capable of being changed.
+
+Set BIOS Config
+~~~~~~~~~~~~~~~
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call ${node_uuid} set_bios_config --arg "name=value"
+
+
+Walkthrough of perfoming a BIOS configuration change:
+
+The following section demonstrates how to change BIOS configuration settings,
+detect that a commit and reboot are required, and act on them accordingly. The
+two properties that are being changed are:
+
+* Enable virtualization technology of the processor
+* Globally enable SR-IOV
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call ${node_uuid} set_bios_config \
+ --arg "ProcVirtualization=Enabled" \
+ --arg "SriovGlobalEnable=Enabled"
+
+This returns a dictionary indicating what actions are required next:
+
+.. code-block:: json
+
+ {
+ "is_reboot_required": true,
+ "is_commit_required": true
+ }
+
+
+Commit BIOS Changes
+~~~~~~~~~~~~~~~~~~~
+
+The next step is to commit the pending change to the BIOS. Note that in this
+example, the ``reboot`` argument is set to ``true``. The response indicates
+that a reboot is no longer required as it has been scheduled automatically
+by the ``commit_bios_config`` call. If the reboot argument is not supplied,
+the job is still created, however it remains in the ``scheduled`` state
+until a reboot is performed. The reboot can be initiated through the
+Ironic power API.
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call ${node_uuid} commit_bios_config \
+ --arg "reboot=true"
+
+.. code-block:: json
+
+ {
+ "job_id": "JID_499377293428",
+ "reboot_required": false
+ }
+
+The state of any executing job can be queried:
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call --http-method GET ${node_uuid} list_unfinished_jobs
+
+
+.. code-block:: json
+
+ {"unfinished_jobs":
+ [{"status": "Scheduled",
+ "name": "ConfigBIOS:BIOS.Setup.1-1",
+ "until_time": "TIME_NA",
+ "start_time": "TIME_NOW",
+ "message": "Task successfully scheduled.",
+ "percent_complete": "0",
+ "id": "JID_499377293428"}]}
+
+
+Abandon BIOS Changes
+~~~~~~~~~~~~~~~~~~~~
+
+Instead of committing, a pending change can be abandoned:
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call --http-method DELETE ${node_uuid} abandon_bios_config
+
+The abandon command does not provide a response body.
+
+
+Change Boot Mode
+----------------
+
+The boot mode of the iDRAC can be changed to:
+
+* BIOS - Also called legacy or traditional boot mode. The BIOS initializes the
+ system’s processors, memory, bus controllers, and I/O devices. After
+ initialization is complete, the BIOS passes control to operating system (OS)
+ software. The OS loader uses basic services provided by the system BIOS to
+ locate and load OS modules into system memory. After booting the system, the
+ BIOS and embedded management controllers execute system management
+ algorithms, which monitor and optimize the condition of the underlying
+ hardware. BIOS configuration settings enable fine-tuning of the
+ performance, power management, and reliability features of the system.
+* UEFI - The Unified Extensible Firmware Interface does not change the
+ traditional purposes of the system BIOS. To a large extent, a UEFI-compliant
+ BIOS performs the same initialization, boot, configuration, and management
+ tasks as a traditional BIOS. However, UEFI does change the interfaces and
+ data structures the BIOS uses to interact with I/O device firmware and
+ operating system software. The primary intent of UEFI is to eliminate
+ shortcomings in the traditional BIOS environment, enabling system firmware to
+ continue scaling with industry trends.
+
+The UEFI boot mode offers:
+
+* Improved partitioning scheme for boot media
+* Support for media larger than 2 TB
+* Redundant partition tables
+* Flexible handoff from BIOS to OS
+* Consolidated firmware user interface
+* Enhanced resource allocation for boot device firmware
+
+The boot mode can be changed via the vendor passthru interface as follows:
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call ${node_uuid} set_bios_config \
+ --arg "BootMode=Uefi"
+
+ openstack baremetal node passthru call ${node_uuid} commit_bios_config \
+ --arg "reboot=true"
+
+.. code-block:: bash
+
+ openstack baremetal node passthru call ${node_uuid} set_bios_config \
+ --arg "BootMode=Bios"
-.. TODO(dtantsur): describe RAID support and inspection
+ openstack baremetal node passthru call ${node_uuid} commit_bios_config \
+ --arg "reboot=true"
Known Issues
============
@@ -66,4 +584,5 @@ into maintenance mode in Ironic. This issue can be worked around by changing
the Ironic power state poll interval to 70 seconds. See
``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``.
-.. _iDRAC: https://www.dell.com/support/manuals/us/en/15/openmanage-software-9.0.1/om_9.0.1_support_matrix/supported-integrated-dell-remote-access-controllers-and-solutions?guid=guid-07259e0b-a788-4a78-8f40-d46ef06a7697&lang=en-us
+.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
+.. _iDRAC: https://www.dell.com/idracmanuals