download | ironic-9bc1106eb28d9ca20fff1f6927cb604eea3e09c9.tar.gz |
Added known issue to iDRAC driver docs
After some period of time, nodes managed by the idrac hardware type may go
into maintenance mode in Ironic.
Change-Id: I78a8b952829d565c203afda9ccff30977989dc71
Diffstat (limited to 'doc/source/admin/drivers/idrac.rst')
-rw-r--r-- | doc/source/admin/drivers/idrac.rst | 11 |
1 files changed, 11 insertions, 0 deletions
diff --git a/doc/source/admin/drivers/idrac.rst b/doc/source/admin/drivers/idrac.rst index 820834f90..f4126c5f5 100644 --- a/doc/source/admin/drivers/idrac.rst +++ b/doc/source/admin/drivers/idrac.rst @@ -60,4 +60,15 @@ hardware type:: .. TODO(dtantsur): describe RAID support and inspection +Known Issues +============ + +Nodes go into maintenance mode +------------------------------ + +After some period of time, nodes managed by the ``idrac`` hardware type may go +into maintenance mode in Ironic. This issue can be worked around by changing +the Ironic power state poll interval to 70 seconds. See +``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``. + .. _iDRAC: http://www.dell.com/learn/us/en/15/solutions/integrated-dell-remote-access-controller-idrac |