summaryrefslogtreecommitdiff
path: root/nova/tests/functional
Commit message (Expand)AuthorAgeFilesLines
* Merge "Handle zero pinned CPU in a cell with mixed policy"Zuul2023-05-091-23/+19
|\
| * Handle zero pinned CPU in a cell with mixed policyBalazs Gibizer2022-12-131-23/+19
* | Merge "Reproduce asym NUMA mixed CPU policy bug"Zuul2023-05-051-0/+74
|\ \ | |/
| * Reproduce asym NUMA mixed CPU policy bugBalazs Gibizer2022-12-131-0/+74
* | Merge "Have host look for CPU controller of cgroupsv2 location."Zuul2023-05-044-0/+4
|\ \
| * | Have host look for CPU controller of cgroupsv2 location.Jorge San Emeterio2023-05-034-0/+4
* | | Save cell socket correctly when updating host NUMA topologyArtom Lifshitz2023-04-251-19/+17
* | | Reproduce bug 1995153Artom Lifshitz2023-04-251-0/+109
* | | Merge "Update min support for Bobcat"Zuul2023-04-041-0/+16
|\ \ \
| * | | Update min support for BobcatSylvain Bauza2023-03-081-0/+16
* | | | Merge "Unbind port when offloading a shelved instance"Zuul2023-03-132-21/+42
|\ \ \ \
| * | | | Unbind port when offloading a shelved instanceArnaud Morin2022-11-292-21/+42
* | | | | fup for power management seriesSylvain Bauza2023-02-231-3/+3
| |/ / / |/| | |
* | | | Merge "Enable cpus when an instance is spawning"Zuul2023-02-181-0/+270
|\ \ \ \ | |_|/ / |/| | |
| * | | Enable cpus when an instance is spawningSylvain Bauza2023-02-101-0/+270
* | | | Stable compute uuid functional testsDan Smith2023-02-011-0/+85
|/ / /
* | | Merge "api: extend evacuate instance to support target state"Zuul2023-02-0115-21/+152
|\ \ \
| * | | api: extend evacuate instance to support target stateSahid Orentino Ferdjaoui2023-01-3115-21/+152
* | | | Merge "compute: enhance compute evacuate instance to support target state"Zuul2023-02-011-7/+7
|\ \ \ \ | |/ / /
| * | | compute: enhance compute evacuate instance to support target stateSahid Orentino Ferdjaoui2023-01-311-7/+7
* | | | Fixup patch for stable-compute-uuid seriesDan Smith2023-01-301-4/+0
|/ / /
* | | Make resource tracker use UUIDs instead of namesDan Smith2023-01-301-0/+3
* | | Merge "Fix rescue volume-based instance"Zuul2023-01-301-9/+77
|\ \ \
| * | | Fix rescue volume-based instanceRajesh Tailor2022-08-261-9/+77
* | | | Merge "Add get_available_node_uuids() to virt driver"Zuul2023-01-274-3/+13
|\ \ \ \
| * | | | Add get_available_node_uuids() to virt driverDan Smith2023-01-204-3/+13
* | | | | Merge "Add virt/node module for stable uuids"Zuul2023-01-261-0/+4
|\ \ \ \ \ | |/ / / /
| * | | | Add virt/node module for stable uuidsDan Smith2023-01-201-0/+4
* | | | | Handle InstanceInvalidState exceptionRajesh Tailor2023-01-231-0/+20
* | | | | Merge "Microversion 2.94: FQDN in hostname"Zuul2023-01-2110-0/+462
|\ \ \ \ \ | |/ / / / |/| | | |
| * | | | Microversion 2.94: FQDN in hostnameArtom Lifshitz2023-01-1710-0/+462
* | | | | Merge "FUP for the scheduler part of PCI in placement"Zuul2023-01-182-48/+51
|\ \ \ \ \
| * | | | | FUP for the scheduler part of PCI in placementBalazs Gibizer2023-01-052-48/+51
* | | | | | Merge "Strictly follow placement allocation during PCI claim"Zuul2023-01-181-24/+15
|\ \ \ \ \ \ | |/ / / / /
| * | | | | Strictly follow placement allocation during PCI claimBalazs Gibizer2023-01-051-24/+15
* | | | | | Merge "Reproduce PCI pool filtering bug"Zuul2023-01-161-0/+85
|\ \ \ \ \ \ | |/ / / / /
| * | | | | Reproduce PCI pool filtering bugBalazs Gibizer2023-01-051-0/+85
* | | | | | Merge "Rename _to_device_spec_conf to _to_list_of_json_str"Zuul2023-01-162-46/+40
|\ \ \ \ \ \ | |/ / / / / | | / / / / | |/ / / / |/| | | |
| * | | | Rename _to_device_spec_conf to _to_list_of_json_strBalazs Gibizer2023-01-052-46/+40
* | | | | Merge "Allow enabling PCI scheduling in Placement"Zuul2023-01-122-33/+10
|\ \ \ \ \ | |/ / / /
| * | | | Allow enabling PCI scheduling in PlacementBalazs Gibizer2023-01-052-33/+10
* | | | | Merge "Test multi create with PCI in placement"Zuul2023-01-121-0/+61
|\ \ \ \ \ | |/ / / /
| * | | | Test multi create with PCI in placementBalazs Gibizer2022-12-211-0/+61
* | | | | Merge "Test reschedule with PCI in placement"Zuul2023-01-121-1/+73
|\ \ \ \ \ | |/ / / /
| * | | | Test reschedule with PCI in placementBalazs Gibizer2022-12-211-1/+73
* | | | | Merge "Support same host resize with PCI in placement"Zuul2023-01-112-2/+138
|\ \ \ \ \ | |/ / / /
| * | | | Support same host resize with PCI in placementBalazs Gibizer2022-12-212-2/+138
* | | | | Merge "Support unshelve with PCI in placement"Zuul2023-01-111-0/+47
|\ \ \ \ \ | |/ / / /
| * | | | Support unshelve with PCI in placementBalazs Gibizer2022-12-211-0/+47
* | | | | Merge "Support evacuate with PCI in placement"Zuul2023-01-101-9/+184
|\ \ \ \ \ | |/ / / /